Iniciar sesión:
Votos - 2, Puntuación media: 5 ( )

Manual de usuario Buhler, modelo 2160

Fabricar: Buhler
Tamaño del archivo: 5.62 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


TURN SIGNALS Move the stalk to position 1 to indicate a right-hand turn. Move the stalk to position 4 to indicate a left-hand turn. The turn signal warning light (and trailer lights, if connected) will also flash when the signals are operated. HEADLIGHTS HIGH/LOW BEAMS With the headlights switched on, pull the stalk to position 3, to change from one beam to the other beam. HEADLIGHT FLASH With low beam headlights on, pull the stalk to position 2, to flash the high beams. Release the stalk to return to low beams. When the headlights are not on, pull the stalk to position 2 to flash the high beam headlights, and then release to turn off the high beams. HORN Press in the end of the stalk, 5, to actuate the horn. 62 63 2-40 SECTION 2 -OPERATION FRONT LIGHTS The headlights, 1, are illuminated when the MASTER LIGHT switch is in the headlight or work light position. All four lights are illuminated when high beam is selected. The outer headlights are illuminated when low beam is selected. The side and lower work lights, 2, are illuminated by touching the work light selector switch, 1, with the master switch in the work light position. The directional signals/hazard lights, 3, are selected with the hazard warning light switch or the multi-function switch. The optional upper front work lights, 4, are illuminated by touching the work light selector switch, 4, with the master switch in the work light position. REAR LIGHTS The parking lights, 1, are illuminated with the light switch in the park, headlight, or work light positions. The brake lights, 1, are illuminated when both brake pedals are depressed. The rear directional/hazard lamps, 2, flash in unison with the front directional/hazard lights. The lower rear work lights, 3, are illuminated when the master switch is in the work light position and work light selector switch, 2, is selected. The center work light may be turned off while leaving the outer lamps illuminated. Use the toggle switch located on the rear of the center lamp’s housing to turn off the light. The upper rear work lights, 4, are illuminated when the master switch is in the work light position and selector switch, 3, is selected. SEVEN PIN AUXILIARY CONNECTOR A standard SAE seven pin connector, 1, is provided to operate the electrical system on implements and trailers. Pin information is as follows: 1 PIN NUMBER CIRCUIT WIRE NUMBER TAPE COLOR MAX AMPS 1 Ground RM4 White N/A 2 Work Lamp RM141 Black 10A 3 Flasher L/H RM287Y Yellow 10A 4 Stop Lamp RM55 Red 10A 5 Flasher R/H RM287Z Green 10A 6 Tail Lamps RM162 Brown 10A 7 Aux Power RM131 Blue 20A The mating SAE seven pin connector P/N 59624 may be purchased from your Buhler Versatile dealer. 2-41 SECTION 2 -OPERATION SINGLE PIN AUXILIARY CONNECTOR A 12-volt single pin power connector, 1, is located at the right rear of the cab. The connector has an 8-amp rating to power electrical monitoring equipment. The connector is activated by the KEY-START switch. The mating single pin connector P/N 86508819 may be purchased from your Buhler Versatile dealer. THREE PIN AUXILIARY MATING CONNECTOR A 12-volt, three pin connector, 2, is installed to allow the attachment and operation of electronic control boxes. Terminal, 3, is controlled by the key switch. This terminal has a 30-amp rating. Terminal, 4, is powered continually. This terminal has an 8-amp rating. Terminal, 5, is ground. The mating male three pin connector P/N 86032122 may be obtained from your Buhler Versatile Dealer. MONITOR MOUNT - --AUXILIARY POWER BAR KIT (P/N 86030509) This kit provides additional power sources for cab mounted monitors. Terminal, 3, is controlled by the key switch. This terminal has a 15-amp rating. Terminal, 4, is powered continually. This terminal has an 15-amp rating. Terminal, 5, is ground. 2-42 SECTION 2 -OPERATION AUXILIARY CONTROL MOUNTING LOCATIONS Two 10 mm cap screws, 2, are located in the right rear panel for attaching an equipment monitor or control box. An alternate mounting position is provided on the inner face of the right front “A” post, 1. NOTE: When installing two-way communication radios: 1. Install the radio on the left side of the cab. 21 2. Route the co-axial cable out the left side of the cab. 3. Mount the antenna on a ground plane on the roof. 4. Make sure the antenna is grounded. AUXILIARY CONTROL CABLE ROUTING Two locations are provided for routing the operating cables from the control box to the attachment. Rear Window Grommet A rubber grommet, 1, is provided to allow equipment control cables, 2, to pass through the rear window frame, 3. Pull the grommet plug, 1, up to remove. Slit the grommet plug from the bottom into the hollow center, 4. Route implement controls through the grommet 1234 plug, then reinstall the grommet plug. Removable Panel A removable panel, 1, is located below the rear window. Remove the panel to access the opening in the rear cab wall. Route the controls through the opening. Store the panel and attaching hardware for future use. ...

Otros modelos de este manual:
cortadoras de césped - 2145 (5.62 mb)
cortadoras de césped - 2180 (5.62 mb)
cortadoras de césped - 2210 (5.62 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría