Resumen del manual


When the forced cooling operation starts by any chance, press the START/STOP but- ton to stop the operation. 3Indicator (Fig. 3) 4Remote Control Signal Receiver 5OPERATION Indicator Lamp (red) 6TIMER Indicator Lamp (green) If the TIMER indicator lamp flashes when the timer is operating, it indicates that a fault has occurred with the timer setting (See Page 14 Auto Restart). 7SUPER QUIET Indicator Lamp (green) 8COIL DRY Indicator Lamp (orange) 9Intake Grille (Fig. 4) 0Front Panel AAir Filter BAir Flow Direction Louver CRight-Left Louver (behind Air Flow Direction Louver) DDrain Hose EAir Cleaning Filter Fig. 5 Outdoor Unit FPipe Unit GDrain port (bottom) HIntake Port IOutlet Port Fig. 6 Remote Control Unit JSLEEP button KMASTER CONTROL button LSET TEMP. button ( / ) MCOIL DRY button NSignal Transmitter OTIMER MODE button PTIMER SET ( / ) button QFAN CONTROL button RSTART/STOP button SSET button TSWING button URESET button VTEST RUN button This button is used when installing the conditioner, and should not be used un- der normal conditions, as it will cause the air conditioner’s thermostat function to op- erate incorrectly. If this button is pressed during normal op- eration, the unit will switch to test opera- tion mode, and the Indoor Unit’s OPERA- TION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously. To stop the test operation mode, press the START/STOP button to stop the air condi- tioner. WCLOCK ADJUST button XRemote Control Unit Display (Fig. 7) YTransmit Indicator ZClock Display [Operating Mode Display \Timer Mode Display ]Fan Speed Display `Temperature SET Display aCOIL DRY Display bSLEEP Display cSWING Display Refer to the folded out page on the cover. En-3 05L256_9315255013-01_En 3 2005.12.9, 11:49 AM PREPARATION CAUTION! Take care to prevent infants from accidentally swallowing batteries. When not using the Remote Control Unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit. If leaking battery fluid comes in contact with your skin, eyes, or mouth, immedi- ately wash with copious amounts of water, and consult your physician. Dead batteries should be removed immediately and disposed of properly, either in a battery collection receptacle or to the appropriate authority. Do not attempt to recharge dry batteries. Never mix new and used batteries, or batteries of different types. Batteries should last about one year under normal use. If the Remote Con- trol Unit’s operating range becomes ap- preciably reduced, replace the batteries and press the RESET button with the tip of a ballpoint pen or other small object. Insert Press in Turn on the Power 1 In the case of a direct line connection, turn on the cir- cuit breaker. Load Batteries (AAA/R03/LR03 ..... 2) 1 Press and slide the battery compartment lid on the re- verse side to open it. Slide in the direction of the arrow while pressing the mark. 2 Insert batteries. Be sure to align the battery polarities ( ) correctly. 3 Close the battery compartment lid. Set the Current time 1 Press the CLOCK ADJUST button (Fig. 6 W). Use the tip of a ball-point pen or other small object to press the button. 2 Use the TIMER SET ( / ) buttons (Fig. 6 P) to adjust the clock to the current time. button: Press to advance the time. button: Press to reverse the time. (Each time the buttons are pressed, the time will be advanced/reversed in one-minute increments; hold the buttons depressed to change the time quickly in ten-minute increments.) 3 Press the CLOCK ADJUST button (Fig. 6 W) again. This completes the time setting and starts the clock. To Use the Remote Control Unit The Remote Control Unit must be pointed at signal receiver (Fig. 1 4) to operate correctly. Operating Range: About 7 meters. When a signal is properly received by the air conditioner, a beeping sound will be heard. If no beep is heard, press the Remote Control Unit button again. Remote Control Unit Holder Slide up Pull out Screws 1 Mount the Holder. 2 Set the Remote Control 3 To remove the Remote Unit. Control Unit (when use at hand). En-4 05L256_9315255013-01_En 4 2005.12.9, 11:49 AM OPERATION To Select Mode Operation 1 Press the START/STOP button (Fig.6 R). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light. The air conditioner will start operating. 2 Press the MASTER CONTROL button (Fig.6 K) to se- lect the desired mode. Each time the button is pressed, the mode will change in the following order. AUTO COOL DRY HEAT FAN About three seconds later, the entire display will reappear. To Set the Thermostat Press the SET TEMP. button (Fig. 6 L). button: Press to raise the thermostat setting. button: Press to lower the thermostat setting. Thermostat setting range: AUTO .................................. 64°F to 88 °F Heating ............................... 60°F to 88 °F Cooling/Dry ........................ 64°F to 88 °F The thermostat cannot be used to set room temperature during the FAN mode (the tempera...

Otros modelos de este manual:
Los acondicionadores de aire - AOU18RL (608.21 kb)
Los acondicionadores de aire - ASU18RL (608.21 kb)
Los acondicionadores de aire - ASU18RL (608.21 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría