Heating Cableshall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. . Transducers & Strain Gages . Cartridge & Strip Heaters . Load Cells & Pressure Gages . Immersion & Band Heaters “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) . Displacement Transducers . Flexible Heaters in medical applications or used on humans. Should any Pro
This allows the user to “Tare- Out” a starting weight in hydraulic weighing applications. To remove the Tare feature turn the unit off and back on again and do not push the On/Off button during the flashing period. 3. Battery Replacement (9 Volt Type) The battery can be replaced simply by removing the single screw at the top of the battery door. Remove the old battery, unplug the cable connector and replace with Eveready type 216 or equivalent. Replace the battery door and secure with the self-t
Approx. 2000 hours battery life DPG3600, DPG5600: 150-1500 hrs. depending on backlight usage Low battery symbol on display Controls & Functions Front button turns gauge on or off, zeros gauge reference gauges, and cycles through min/max functions Internal push buttons for selection of engineering units and auto shutoff times. Pass code protected setup and calibration. DPG3600, DPG5600: Front button activates backlighting for 1 minute Min/Max Functions Minimum and maximum readings stored 3 times
Apply full-scale pressure. The character display will alternate between +SPAN and CAL. Adjust for a display indication of full- scale pressure using the UP and the DOWN buttons. Apply 50% full-scale pressure. The character display will alternate between +MID and CAL. Adjust for a display indication equal to 50% of full-scale pressure using the UP and the DOWN buttons. Gauge Reference Vacuum Gauges Apply zero pressure by venting the gauge port to atmosphere. The character display will alternate b
Turn gauge off when not in use to conserve battery life. Basic Configuration Engineering Unit Selection Engineering unit selection is done via internal buttons to help prevent accidental or unauthorized changes. The selected engineering unit is stored in non-volatile memory and will be retained even with the gauge off or batteries removed. The available engineering units depend on the sensor range and available display resolution. Compound (inHg/PSIG) gauges must be changed to display single- un
An OMEGA Te c h n o lo g ie s Co m p a n y DP18 Series Model DP18-RT1 True RMS Ammeter .............................................................................................................................................................................................................................................................................................................................................................................................................................