The holes are tapped for #8-32 screws and are 0.31" deep. We suggest using #8-32 x 3/8" stainless steel screws. Some different options are shown below. FORK * To avoid electro-static discharge and sensor malfunction, the CS2000 should be mounted to a grounded metal surface. If this is not possible, a grounding wire should be connected from one of the mounting screws to a suitable ground. - 5 Installation Installation CS2000 Wiring: The CS2000 comes with an 8' - 4 conductor cable. Refer below for wire designations. RED = 10-30 VDC BLK = Common WHT = Output ORN = NPN / PNP Output Selector CS2000 RED 10-30V LOAD BLK WHT ORN Interfacing to Load - NPN Output: WHT ORN CS2000 Interfacing to Load - PNP Output: LOAD RED 10-30V BLK Interfacing to 5V Logic - NPN Output: Sourcing Other than Supply Voltage - PNP Output: WHT +5V 5V Logic 1K 1/4W *5V Com. and 10-30V Com. must be connected together ORN CS2000 RED 10-30V BLK WHT ORN Supply Voltage *Output Source Com. and Supply Com. must be connected together CS2000 LOAD RED BLK 10-30V Output Source Voltage 10-30V Optoisolator 12V = 1K 1/4W 24V = 2K 1/4W *Resistor values are to source approx. 10mA to the optoisolator WHT ORN CS2000 Interfacing to Optoisolator - NPN Output: RED 10-30V BLK WHT ORN 12V = 1K 1/4W 24V = 2K 1/4W Optoisolator *Resistor values are to source approx. 10mA to the optoisolator CS2000 Interfacing to Optoisolator - PNP Output: RED BLK 10-30V - 6 Installation Installation CS2000-QD Wiring: The CS2000-QD comes with a 6" quick disconnect M12 - 4 pin male cable/connector (Turck P/N RS4.4T-2). Refer below for wire designations. Pin 1. BRN = 10-30 VDC Pin 2. WHT = Output Pin 3. BLU = Common Pin 4. BLK = NPN / PNP Output Selector 4 1 2 3 CS2000-QD BRN 10-30V LOAD BLU WHT BLK Interfacing to Load - NPN Output: WHT BLK CS2000-QD Interfacing to Load - PNP Output: LOAD BRN 10-30V BLU Interfacing to 5V Logic - NPN Output: Sourcing Other than Supply Voltage - PNP Output: WHT +5V 5V Logic 1K 1/4W *5V Com. and 10-30V Com. must be connected together BLK CS2000-QD BRN 10-30V BLU WHT BLK Supply Voltage *Output Source Com. and Supply Com. must be connected together CS2000-QD LOAD BRN BLU 10-30V Output Source Voltage 10-30V Optoisolator 12V = 1K 1/4W 24V = 2K 1/4W *Resistor values are to source approx. 10mA to the optoisolator WHT BLK CS2000-QD Interfacing to Optoisolator - NPN Output: BRN 10-30V BLU WHT BLK 12V = 1K 1/4W 24V = 2K 1/4W Optoisolator *Resistor values are to source approx. 10mA to the optoisolator CS2000-QD Interfacing to Optoisolator - PNP Output: BRN BLU 10-30V - 7 Operation Operation Label Placement: For best results, position straight edge of label under the sensing area. Try to avoid sensing on rounded corners or other curved areas. Refer to diagram below. ACME LABELS ACME LABELS AC ACME LABELS ACME LABELS ACME LABELS ACME LABELS Label Web (label backing) Sensing Area Push-button Functions: Push-button is depressed for... LED's Function Less than 1 second 1 to less than 5 seconds 5 to less than 10 seconds 30+ seconds YEL/GRN - off YEL - on GRN - on YEL/GRN - toggle Outputs a stop pulse Adjust Label Sensitivity (refer to page 10) Set Missing Label Compensation (refer to page 11) Enter Program Mode (refer to page 12) - 8 Operation Operation LED Functions: Yellow - comes on when label backing (web) is under the sensing area Red - comes on when output is active - NPN sinking or PNP sourcing Green - comes on when label over label backing is under the sensing area Operation Features: The CS2000 has 3 different operation features that can be changed to accommodate individual needs. They are Output Mode, Light/Dark Operation, and Contrast Setting. Operation Features - Output Mode: The CS2000 has 2 different output modes - Level Shift Output and Pulse Output. Level Shift Output is either on for the length of the web, or on for the length of the label, depending on the Light/Dark Operation setting. Pulse Output either comes on for 2 m.s. at the leading edge of a label, or goes off for 2 m.s. at the leading edge of a label, depending on the Light/Dark Operation setting. Refer to Program Mode (page 12) for more information. Operation Features - Light/Dark Operation: The CS2000 allows you the option of having the sensor's output active on the web (Light Operate), or having the sensor's output active on the label (Dark Operate). Light Operate is either on for the length of the web, or comes on for 2 m.s. at the leading edge of a label, depending on the Output Mode setting. Dark Operate is either on for the length of the label, or goes off for 2 m.s. at the leading edge of a label, depending on the Output Mode setting. Refer to Program Mode (page 12) for more information. Operation Features - Contrast Setting: The CS2000 comes with a Normal Contrast Setting and a Low Contrast Setting. Normal Contrast Setting should be fine for 99% of labels. But with labels that offer very little contrast between the web and the label, the Low Contrast Setting can be selected very easily...

Otros modelos de este manual:
Otras herramientas - CONTECH CS2000 (474.6 kb)
Otras herramientas - CONTECH CS2000-QDCS2000 (474.6 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría