Iniciar sesión:
Votos - 3, Puntuación media: 3.3 ( )

Manual de usuario 3Com, modelo RAID Controller ACS-77100

Fabricar: 3Com
Tamaño del archivo: 847.21 kb
Nombre del archivo: 6de3ef7c-03cc-47d9-98e0-e19eafcea2d0.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


4. The Initialize Disk dialog box will appear, select the disk number and select the GPT (GUID Partition Table) partition style. (Figure 3.5.2.A) 5. In the drive box to the right shows Unallocated, right click and select New Simple Volume. (Figure 3.5.2.B) 6. The New Simple Volume Wizard dialog box will appear, click Next to continue. 7. After selecting partition type, specifying partition size and assigning drive letter, the Format Partition dialog box will appear, you have the option of selecting the Quick Format option. This allow mach fast formatting, however, this disallow Disk Management to check the drive sector for errors. Click Next to start the format process. 8. Your drive should now appear in your Computer and ready for use. 4. Management 4.1. LCD displayed Messages The status of the ACS-77100 can be viewed through the LCD display. By using the scroll buttons to scroll through the messages, the following information is available. RAID level and capacity Disk drive model Disk capacity Controller firmware version Controller serial number Fan and temperature status 4.1.1. Booting Messages LCD Display Message ACS-77100 is booting ACS-77100 is initializing the installed disks 4.1.2. Set over 2TB Capacity Messages LCD Display Message Press ENT button to set enable/disable over 2TB Enable over 2TB capacity Disable over 2TB capacity RAID Box Boot RAID Box Initialize Disks Enable over 2T Press ENT select Enable over 2T (NO) Enable over 2T (YES) 4.1.3. Initialization Messages LCD Display Message Create a new RAID. RAID Initialization completed successfully. New array being created. LCD Display Message Too many bad sectors in Disk X, initialization cannot proceed. Disk X failed during the initialization. The initialization cannot proceed. 4.1.4. System Ready Messages LCD Display Message ACS-77100 is ready for use. Create New RAID? No (Yes) RAID INIT XX.X % Total: XXXX GB RAID Init 100 % XXXX GB INIT OK! RAID INIT Failed DX offline RAID INIT Failed DX Bad sectors RAID Box Ready hh:mm 4.1.5. Rebuild Messages Message Rebuilding data to a new disk (Disk X) since Disk X failure. Disk rebuild completed successfully. The capacity of the new disk (Disk X) is too small. XXX GB is the capacity of the new disk. LCD Display YYY GB is the minimum disk capacity of the RAID. Disk rebuilding fail since Disk X failed. 4.1.6. Error Messages LCD Display Message Disk rebuilding fail since too many bad sectors in Disk X RAID Failure Messages The RAID failed since there are not enough disk members. The RAID failed since the sequence of the disks is incorrect. The current sequence is displayed within the < > space. The RAID has been failed, but all disks exist. DX Rebuild XX.X% Total: XXX GB DX Rebuild 100% XXX GB OK! DX Rebuild Fail XX GB < YYY GB DX Rebuild Fail DX offline DX Rebuild Fail DX Bad sectors RAID Fail code: 0 RAID Fail code: 1 RAID Fail code: 2 Disk Failure Message LCD Display Message Disk X failed. Fan Failure Message LCD Display Message Fan failure. The xxxx rpm is the current rpm for the fan. Overheating Error Message LCD Display Message System overheating. The XX is the current temperature 4.2. StorConn GUI introduction ACS-77100 support remote RAID subsystem monitoring by web-based GUI. This section covers the introduction of the monitoring software. Key Features .. Graphical User Interface (GUI) .. Multi-interface support .. Remote monitoring .. Web-based environment .. Event notification StorConn monitoring program, a web-based GUI supporting In-band interface via SATA channel and Out-band interface via RS-232, by which customers can monitor the RAID status from web browsers at a remote site. The StorConn is also capable of sending out notification mail to the customers. Disk X fail Fan Fail XXXX rpm Temperature!! XX°C > 50°C 4.2.1. RAID status monitoring window 1. RAID controller tab: Allow customer to select which RAID to monitor. 2. Controller information: Lists model name, serial number and current RAID level. 3. Disk status: Allows you to monitor the status of each of the disk drives. 4. Disk information: Lists model name and capacity of each of the disk drives. 5. Re-build / initialize progress: Tracks the re-building or initialization process. | Pin2 to A | Pin4 to B | Pin6 to C | The data and configurations on the array are not affected by firmware updating. The HyperTerminal is bundled as standard with Microsoft Windows operating system. It will be found in the Communications folder. The program can also be download from Higraeve Software at 5. Update Firmware ACS-77100 allows the customers to update firmware via RS-232 interface. The firmware can be updated from a host PC w...

Otros modelos de este manual:
Equipo de red - RAID Controller ACS-77100 (847.21 kb)
Equipo de red - RAID Controller ACS-77100 (847.21 kb)
Equipo de red - RAID Controller ACS-77100 (847.21 kb)
Equipo de red - RAID Controller ACS-77100 (847.21 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría