Iniciar sesión:
Votos - , Puntuación media: ( )

Manual de usuario HP, modelo HP SAS Host Bus Adapters

Fabricar: HP
Tamaño del archivo: 246.75 kb
Nombre del archivo:

Idioma del manual:en

El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere


Otros manuales para este modelo:

Resumen del manual


HP 8 Internal Port SAS Controller and HP Multi-Port Internal SAS Controller

Updating the adapter firmware to version 1.23.33 or later might change the target ID of disk
devices.
This occurs on HP Integrity rx2660, rx3600, and rx6600 servers when an Integrated RAID
volume is configured on the controller and you perform one of the following actions:

Update the adapter firmware offline using sasflash.efi.

Boot to an HP-UX or Ignite-UX disk containing the sasd driver from one of the following
releases, which download firmware version 1.23.33 to the adapter during boot:

B.11.23.0712

B.11.31.0712
Changing the target ID might cause physical disks, including the OS boot disk, to become
inaccessible. If some of the disks from the IR volume are inaccessible, the volume can become
degraded or fail.
NOTE:
The target ID change does not occur on systems without a RAID-1 volume. It also
does not occur on Bl860c servers with the HP Multiport SAS Controller.
For detailed information on how to avoid or correct this problem, see Updating Internal SAS
Controller Firmware to Version 1.23.33 Or Later
at:
http://www.hp.com/go/sas-hba-docs
Click the link for your HP-UX version. The document is listed alphabetically in the “Setup and
install - general” section.

Before replacing a failed disk, note its Device Special File (DSF) information.
If you shut down a server to replace a failed disk offline, the DSF of the failed disk is not visible
in the ioscan utility when the server restarts. The DSF is required by the replace_tgt
command to rebuild the array with the new disk.
Corrective Action: Before you shut down the server, run the ioscan utility and note the DSF
information for the failed disk.
For more information on replacing disks, see the HP 8 Internal Port SAS Controller and HP
Multi-Port Internal SAS Controller Support Guide
at:
http://www.hp.com/go/sas-hba-docs
Click the link for your HP-UX version. Support guides are listed alphabetically in the “User
guide” section.
AH303A PCIe SC44Ge SAS Host Bus Adapter

Virtual Partitions do not boot in multi-initiator configurations.
Virtual Partitions (vPars) using an HP StorageWorks MSA60 or MSA70 enclosure does not
boot if AH303A cards assigned to multiple virtual partitions are connected to the same JBOD.
Under the vPars I/O resource assignment rules, a host bus adapter cannot be shared among
multiple virtual partitions.
Corrective Action: None. This issue is corrected in vPars A.05.03 (B.11.31.0803).

There is a setboot command issue on specific servers.
The setboot -p/-a/-h command fails when issued on an AH303A adapter installed in
slots 3 or 4 on HP Integrity rx3600 and rx6600 systems.
Corrective Action: Install AH303A adapters in nonswitched slots. This issue is corrected in
patch PHKL_37278.
Known problems and limitations
5


...

Otros modelos de este manual:
Equipo de red - HP-UX 11i v3 I/O Cards (246.75 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría