|
Otros manuales para este modelo:
Resumen del manual
Corrective Action: This issue is corrected in vPars A.04.06 (B.11.23.0809).
•
Virtual Partitions do not boot if hardware reconfiguration changes the hardware path
under vPars A.4.05.
Virtual Partitions (vPars) using an HP StorageWorks MSA50/MSA60/MSA70 enclosure do
not boot if hardware paths change due to hardware reconfiguration. For more information
on the impacts of hardware reconfiguration, see the Ignite-UX and SAS Devices white paper
at:
http://docs.hp.com/en/oshpux11i.html
Corrective Action: This issue is corrected in vPars A.04.06 (B.11.23.0809).
•
There is a setboot command issue on specific servers.
The setboot -p/-a/-h command fails when issued on an AH303A adapter installed in
slots 3 or 4 on HP Integrity rx3600 and rx6600 systems.
Corrective Action: Install AH303A adapters in nonswitched slots. This issue is corrected in
patch PHKL_37869. You can download patches from the IT Resource Center at:
http://itrc.hp.com/
4.3 All Controllers Supported by SerialSCSI-00
•
System panic when downgrading the sasd driver.
CAUTION:
Installing version B.11.23.0712 or earlier of the sasd driver downgrades the
adapter firmware. This can cause RAID volumes in the system to become degraded. Back
up important data before downgrading the adapter firmware.
If you install an older version of the sasd driver and version B.11.23.0712 is installed, the
system panics with the following stack trace:
panic: post_hndlr(): Unresolved kernel interruption
Stack Trace:
IP Function Name
0xe0000000005a95e0 post_hndlr+0xcc0
0xe0000000005a8460 vm_hndlr+0x220
0xe000000000d90780 bubbledown
0xe000000000713610 spp_remove_from_list+0xf0
0xe000000000713240 spp_alloc+0xd0
0xe0000000007137a0 kmem_lpc_alloc+0x100
0xe000000000713a00 kalloc_internal+0x90
0xe00000000073bbf0 alloc_mem+0x90
0xe00000000073bf10 get_kmem+0x130
0xe00000000073c260 kmem_arena_refill+0x110
0xe0000000006ebf70 kmem_arena_varalloc+0x1f0
0xe00000000118eba0 ipmi_init+0x1c0
0xe0000000009e28b0 isc_table_traverse+0x1e0
0xe0000000009dbfa0 wsio_init_end+0x40
0xe000000000c7d320 io_virt_mode_config+0x1c0
0xe0000000017716b0 DoCalllist+0x3a0
End of Stack Trace
This problem happens on HP Integrity rx2600, rx3600, rx6600, BL860c systems, and on rx7640
and rx8640 systems with AH303A adapters installed.
Corrective Action: Reboot the system to recover from the panic.
5 Compatibility and Installation Requirements
This section describes the compatibility information and installation requirements for this release.
For specific installation instructions, see the HP 8 Internal Port SAS Controller and HP Multi-Port
5 Compatibility and Installation Requirements
5
...Otros modelos de este manual:
Equipo de red - HP-UX 11i v2 I/O Cards (255.35 kb)