Updating HP 8 Internal Port SAS Host Bus Adapter And HP Multiport SAS
Controller Firmware To Version 1.23.33 Or Later
Updating the adapter firmware to version 1.23.33 or later might change the target ID of disk
devices. This occurs on rx2660, rx3600, and rx6600 servers when an Integrated RAID volume is
configured on the controller and you perform one of the following actions:

Update the adapter firmware offline using sasflash.efi.

Boot to an HP-UX or Ignite-UX disk containing the sasd driver from one of the following
releases, which download firmware version 1.23.33 to the adapter during boot:
— B.11.23.0712
— B.11.31.0712
Changing the target ID might cause physical disks, including the OS boot disk, to become
inaccessible. If some of the disks from the IR volume are inaccessible, the volume can become
degraded or fail.
The target ID change does not occur on systems without a RAID-1 volume. It also does not occur
on Bl860c servers with the HP Multiport SAS Controller.
This document provides server-specific procedures to update the adapter firmware and maintain
the RAID configuration.
Updating The Adapter Firmware On rx2660 Servers
To update the adapter firmware on rx2660 servers, follow these steps:
1.
Shut down and power off the system.
2.
Label the disks as follows:
A B C D E F G H
3.
Partially remove each drive from its bay.
4.
Boot to EFI, and use sasflash.efi to upgrade the firmware.
5.
Shut down and power off the system.
6.
Move the drives to different bays, as follows:
H G F E D C B A
7.
Boot the system.
Updating The Adapter Firmware On rx3600 Servers
To update the adapter firmware on rx3600 servers, follow these steps:
1.
Shut down and power off the system.
2.
Label the disks as follows:
A B C
D E
F G H
3.
Partially remove each drive from its bay.
4.
Boot to EFI, and use sasflash.efi to upgrade the firmware.
5.
Shut down and power off the system.
6.
Move the drives to different bays, as follows:
D C B
A H
G F E
7.
Boot the system.
Updating HP 8 Internal Port SAS Host Bus Adapter And HP Multiport SAS Controller Firmware To Version 1.23.33 Or
3
Later


...

Otros modelos de este manual:
Equipo de red - HP-UX 11i v2 I/O Cards (166.78 kb)
Equipo de red - HP-UX 11i v3 I/O Cards (166.78 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría