Resumen del manual


Any AMX Modero intercom-enabled touch panel can interface with the Metreau Entry Communicator and allow residents to open doors, gates and more. Refer to the Metreau Entry Communicators Operation/Reference Guide (available online at for additional installation details and instructions on positioning the integrated video camera, using the Configuration Manager, using the full-duplex intercom, and NetLinx Programming information. Note: The MET-ECOM-DNS-B is intended for installation in interior or protected environments. Product Specifications Rear Panel Components FIG. 2 shows the location of the rear panel components for the MET-ECOM-DNS-B. Wiring and Connections Note: To avoid any damage to the electronic component, installation must be performed in an ESD safe environment. Note: Do not connect power to the MET-ECOM-DNS-B until the wiring is complete. After you have completed the installation, consult the Using the Configuration Manager section of the Metreau Entry Communicators Operation/Reference Guide. FIG. 1 MET-ECOM-DNS-B Metreau Entry Communicator with Display MET-ECOM-DNS-B Specifications Power: • PoE powered – no local Power Supply needed • IEEE 802.3af Compliant Front Panel Components: • OLED Display • Integrated Color Video Camera • Speaker • Dual Color LED Status Bar: (Yellow/ Red) can be used to provide feedback, to attract attention for action, or as general indicator. • Pushbutton (Doorbell) • Microphone OLED Display: • 4-bit Gray Scale • 1.6” Diagonal Display • 180° Viewing Angle • 2000:1 Contrast Ratio • Unit stores up to 50 .bmp images Integrated Color Video Camera: • QVGA 320 x 240 • Supports Motion JPEG (MJPEG) and H.263 codecs. • Viewing Angle: 42° Speaker: • 8 Ohm, 2W • 80dB SPL (sound pressure level at 1 meter) • Meets G.711 sound standard Microphone: • -40 dB sensitivity, built-in echo cancellation (telephone quality) • Full duplex communication • VoIP Telephony Rear Panel Components: • Camera Viewing Angle Adjustment • Ethernet Port - 10/100 Ethernet with PoE. LEDs show communication activity, connection status, speeds, and mode information: SPD (speed) - Green LED lights On when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps. L/A (link/activity) - Orange LED lights On when the Ethernet cables are connected and terminated correctly, and blinks when receiving Ethernet data packets. • ID/Reset pushbutton: Push to set the NetLinx ID (Device only) assignment for the device. Push and hold for at least 10 seconds to reset to factory default settings. Speaker OLED display Video Camera Microphone Dual Color LED Status Bar (Yellow / Red) Pushbutton (Doorbell) MET-ECOM-DNS-B Specifications (Cont.) Rear Panel Components (Cont.): • Status LED: Green LED provides an indication of both the system status and communication status with the target Master. 1 blink every 5 seconds indicates there is currently active communication between the Metreau unit and a target Master. • 2 Multi-Purpose I/Os (5V): 2-channel binary I/O ports for contact closure with each input being capable of voltage sensing. Input format is software selectable with interactive power sensing for IR ports. • 2 Low Voltage Relays (1A contact): 2-channel singlepole single throw relay ports with each relay being independently controlled and supporting up to 2 independent external relay devices. Dimensions (HWD): • 6.500” x 4.185” x 1.493” (16.510 cm x 10.629 cm x 3.792 cm) Weight: 1.30 lbs (0.59 kg) Operating Environment: 32° - 104° F (0° - 40° C) Colors Available: Black Included Accessories: • Installation Kit - includes 2 Phoenix connectors (female, 3.5mm) and one Ferrite clip. Other AMX Equipment: • Rough-In Box (required for installation - FG039-13) • PS-POE-AF Power-over-Ethernet (PoE) power supply (FG423-80) • NXA-ENET24 Managed Ethernet Switch (FG2178-60) • NXA-ENET24PoE Managed Ethernet Switch, Power Over Ethernet (FG2178-61) Certifications: • FCC Class B • CE • IEC60950 • RoHS FIG. 2 MET-ECOM-DNS-B (rear panel) Camera Viewing Ethernet Connection 2 Multi-Purpose I/Os (5V) 2 Low Voltage Relays (1A Contact) ID/Reset pushbutton Mounting STATUS (red LED) Angle Adjustment Magnets (2 on each side) Ethernet 10/100 Base-T RJ-45 Wiring Configuration Mounting Specifications The table below describes the pinouts, signals, and pairing for the Ethernet 10/100 Base-T FIG. 5 shows the recommended cutout for the MET-ECOM-DNS-B Rough-In Box. Use connector and cable. these dimensions for wall surface installations using expansion clips. Ethernet Pinouts and Signals Pin Signals Connections Pairing Color 1 TX + 1 --------- 1 1 --------- 2 White-Orange 2 TX 2 --------- 2 Orange 3 RX + 3 --------- 3 3 --------- 6 White-Green 4 no connection 4 --------- 4 Blue 5 no connection 5 --------- 5 White-Blue 6 RX 6 --------- 6 Green 7 no connection 7 --------- 7 White-Brown 8 no connection 8 --------- 8 Brown The MET-ECOM-DNS-B uses CAT5/CAT6 wire via the Ethernet port for PoE power. PoE (Power Over Ethernet) Use the ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría