Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario White Rodgers, modelo pmnACM/ACB

Fabricar: White Rodgers
Tamaño del archivo: 1.18 mb
Nombre del archivo: d88e2c48-aa7b-454a-ac5f-e9b4f3f20fa2.pdf
Idioma del manual:enfr
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


With Media Filter ACM1000 ACM1200TM ACM1400 ACM1600 ACM2000 ACM2000U ACM2000X No Media Filter ACB1000 ACB1400 ACB1600 ACB2000 OWNER’S MANUAL • Installation • Operation • Technical Repair Guide • Repair and Upgrade Parts Please read and familiarize yourself with the contents of this manual before installing, operating or performing maintenance on the unit. White-Rodgers is a division PART NO. 37-6383C of Emerson Electric Co. Replaces 37-6383B INTRODUCTION The White-Rodgers Air Cleaner Compartment comes complete with a 5” media furnace air filter. This filter must be changed every three months to maintain efficiency of the filter and furnace system. For maximum efficiency, the compartment can be upgraded to a White-Rodgers Electronic Air Cleaner. Please read instructions before installing and using the Air Filter Compartment. ! CAUTION ! WARNING The fiber filter used in this cabinet for air cleaning must be replaced every 90 days. Your heating and cooling efficiency will decrease due to insufficient air flow when filter becomes dirty. Do not attempt installation of this unit unless you are familiar with the necessary tools, equipment, and potential hazards. Installation should be performed only by a qualified service provider. Failure to do so could result in reduced performance of the unit, serious personal injury or death. GUARANTEE White-Rodgers will not assume any responsibility for component failures due to incorrect installation procedures. RULES FOR SAFE INSTALLATION AND OPERATION 1. Read the Owners Manual and the Rules for Safe Operation carefully. Failure to follow these rules and instructions could cause a malfunction of filter or unsatisfactory service. ! WARNING Installation of this unit must comply with local electric codes or other applicable codes. Review and understand local codes prior to installation. ! WARNING Before installing or servicing, always shut off electricity. This will prevent any electrical shocks. 2. Follow a regular service and maintenance schedule for efficient operation. TABLE OF CONTENTS Rules for Safe Installation and Operation ............2 How the Air Filter Works ......................................3 Construction of the Air Filter Compartment .........3 Preinstallation.......................................................4 Installation ............................................................6 Maintenance.........................................................7 Repair and Upgrade Parts ...................................7 BASIC TOOLS REQUIRED Tin Snip Screwdriver Rule or Tape Measure Drill DID YOU GET THE RIGHT SIZE AIR FILTER COMPARTMENT Model ACB & ACM1000 are designed for heating or cooling blowers delivering 600 to 1200 cubic feet of air per minute (cfm.) Model ACM1200TM is designed for heating or cooling blowers delivering 1000 to 1600 cfm. Model ACB & ACM1400 are designed for heating or cooling blowers delivering 1000 to 1600 cfm. Model ACB & ACM1600 are designed for heating or cooling blowers delivering 1200 to 1800 cfm. Model ACB, ACM2000 & ACM2000X are designed for heating or cooling blowers delivering 1600 to 2200 cfm. Model ACM2000U is designed for heating or cooling blowers delivering 1600 to 2200 cfm. with insulation on door and universal rail. Before installing the filter, make sure you have selected the proper size unit for your heating and cooling system requirements. See specifications on page 4. 2 3 AIR FILTER COMPARTMENT 5" FILTER DOOR FRONT VIEW IF RAILS AND CLIPS ARE REQUIRED, CLIP RAILS IN PLACE BEFORE INSERTING FILTER CLIPS RAIL AND CLIPS RAIL DIRTY AIR IN 5" FILTER FILTERED AIR OUT HOW THE AIR FILTER WORKS Dirty air flows through your return air ducts and enters the compartment where particles (hair, lint, etc.) are removed by the filter. See figure 1. Filtered air re-enters to the supply duct system of your building. Not only is your air filter compartment easy to install, it is also easy to maintain. Its basic components, and their functions, are as follows: (See Figure 2) Air Filter Compartment- mounts to existing duct work and houses the filters or optional electronic air cleaner cells. NOTE: To upgrade your air filter compartment with a high efficiency Electronic Air Cleaner, use the ACR (Air Cleaner Retrofit) Kit for your model. See page 7 for details. 5” Filter - collects dust, dirt and other particles. Note ACM2000U Compartment: This unit has removable rails (see figure 2A). This unit is installed with the rails to be used with a 24.5” x 19.9” x 4.3” filter. Remove the rails and a 5” filter may be used. CONSTRUCTION OF THE AIR FILTER COMPARTMENT Figure 1 Figure 2 Figure 2A PREINSTALLATION LOCATING THE AIR FILTER Your air filter must be mounted in the return air duct of a central forced-air system, on the air entering side of your furnace. (See Figure 3 for example.) Select a location that meets the following: 1. The face of the filter will be at a right angle to the air stream. 2. Allow 25” of clearance in fro...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría