Iniciar sesión:
Votos - 4, Puntuación media: 3.5 ( )

Manual de usuario ColdTech, modelo CFD-2R

Fabricar: ColdTech
Tamaño del archivo: 2.64 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


= minutes max = maximum hr. = hours N/A = not applicable Warning: Do not change the default settings of your ColdTech unit without consulting a qualified service technician or theColdTech service department. -9 Applicable to Models: CFD-1F, CFD-2F, CFD-3F ColdTech® Freezer Settings Temperature set to -4 F Parameter Function Set Range Default E1 Lower Setpoint Limit -40 F ~ set temp -10 F E2 Higher Setpoint Limit set temp ~ 120 F 20 F E3 Hysteresis, temp variance 1 ~ 18 F 10 F E4 Comp. start delay time 0 ~ 10 min. 3 min. E5 Offsetonroomtemp -5~5F 0F E6 Offsetonevaptemp -5~5F 0F F1 Max. defrost duration 1 ~ 60 min. 30 min. F2 Defrost interval time 0 ~ 24 hr. 6 hr. F3 Defrost termination temp 32 ~ 68 F 68 F Key F = Farenheit (degrees) temp = temperature min. = minutes max = maximum hr. = hours N/A = not applicable Warning: Do not change the default settings of your ColdTech unitwithout consulting a qualified service technician or the ColdTech service department. -10 SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Compressor not running. Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker. Power cord unplugged. Plug in power cord. Thermostat set too high. Set thermostat to lower temperature. Cabinet in defrost cycle. Wait for defrost cycle to finish. Condensing unit runs for Excessive amount of warm product Allow adequate time for long periods of time. placed in cabinet. product to cool down. Prolonged door opening or door ajar. Ensure doors are closed when not in use. Avoid opening doors for long periods of time. Door gasket(s) not sealing properly. Ensure gaskets are snapped in completely. Remove gasket and wash with soap and water. Check condition of gasket and replace if necessary. Dirty condenser coil. Clean the condenser coil. Evaporator coil iced over. Unplug unit and allow coil to defrost. Make sure thermostat is not set too cold. Ensure that door gasket(s) are sealing properly. Cabinet temperature is too warm. Thermostat set too warm. Blocking air flow. Excessive amount of warm product placed in cabinet. Fuse blown or circuit breaker tripped. Dirty condenser coil. Prolonged door opening or door ajar. Evaporator coil iced over. Set thermostat to lower temperature. Re-arrange product to allow for proper air flow. Make sure there is at least four inches of clearance from evaporator. Allow adequate time for product to cool down. Replace fuse or reset circuit breaker. Clean the condenser coil. Ensure doors are closed when not in use. Avoid opening doors for long periods of time. (see above) Cabinet is noisy. Loose part(s). Tubing vibration. Locate and tighten loose part(s). Ensure tubing is free from contact with other tubing or components. -11 The New Symbol of Innovation™ MEMO RETAIN THIS MANUAL FOR FUTURE REFERENCE Please read the entire manual carefully before installation and operation. If certain recommended procedures are not followed, warranty claims will be denied. Notice: ColdTech reserves the right to make changes in ...

Otros modelos de este manual:
Refrigeradores - CFD-1F (2.64 mb)
Refrigeradores - CFD-2F (2.64 mb)
Refrigeradores - CFD-3F (2.64 mb)
Refrigeradores - CFD-3R (2.64 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría