Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario Heatmaster, modelo Gas Burner

Fabricar: Heatmaster
Tamaño del archivo: 536.32 kb
Nombre del archivo: 3e32febd-074e-4a86-8638-dd7f8b5015dd.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Do not try to light any appliance. . Do not touch any electrical switch; do not use any phone in your building. . Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. . If you cannot reach your gas supplier, call the fire department. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency or the gas supplier. IMPORTANT: READ INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION OF LOG SET. NOTE: DAMPER MUST BE OPEN ACCORDING TO CHART ON PAGE 3 OF THESE INSTRUCTIONS OR FULLY OPEN WHEN LOG SET IS OPERATING. This burner unit must be installed only in a fully-vented, solid-fuel burning fireplace with a working flue and constructed of noncombustible material. The damper and chimney must be free of any obstructions. This log set is designed to burn with a smoky, yellow flame and must be vented for this reason. The fireplace chimney must have a permanent vent opening to the atmosphere of not less than the minimum square inches stated in Table 1 and Table 2 on page 3 of these instructions. If it is smaller, do not use this log set. IMPORTANT: Ensure that the chimney draft is adequate by holding a lit match or candle at the top edge of the fireplace opening. This will indicate if air movement is toward the fireplace. If draft is inadequate, do not operate logs until draft is adequate. If you smell fumes from the burner in the room when the damper is fully open, it indicates that the fireplace draft is insufficient. If the draft is insufficient, have the chimney inspected by a qualified chimney sweep. DO NOT OPERATE LOGS UNTIL THE FIREPLACE DRAFT IS CORRECTED. Do not burn solid fuels in a fireplace where a decorative appliance is installed. 14-2000 GENERAL INFORMATION . A fireplace screen must be in place when logs are operating and, unless other provisions for combustion air are provided, the screen must have an opening(s) for the introduction of combustion air. . If glass doors are used with this log set, open doors fully when unit is operating. . Open damper according to the chart on page 3 of these instructions (or fully open) and be sure damper stop clamp is installed. (See damper stop instructions listed on page 5.) Gas supply pipe must be 1/2” minimum I.D. or larger (3/4” if gas line is longer than 20 feet). The minimum inlet gas supply pressure for the purpose of input adjustment is 7 inches for natural gas and 11 inches for LP gas. The maximum inlet gas supply pressure is 10.5 inches for natural gas and 13 inches for LP gas. . Solid fuels shall not be burned in a fireplace where a decorative appliance is used. . The installation and provisions for combustion and ventilation air must conform with the National Fuel Gas Code, ANSI Z223.1. . The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). . The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). . KEEP APPLIANCE AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS. . Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. VENTING SYSTEM MAINTENANCE An annual examination and cleaning of the venting system by a qualified person is recommended. CLEANING YOUR GAS LOG SET Periodically you may want to remove the soot build-up on the logs by lightly brushing the logs with a soft brush. Also, occasionally, visually inspect your burner pan and pilot for proper operation (Fig. 1 and Fig. 2 below). Fig. 1 Fig. 2 2 Minimum Permanent Free Opening, Square Inches for Masonry Built Fireplaces Chimney Height (Feet) 18” Log Set 24” Log Set Minimum Opening (Square Inches) 6 49.2 56.6 8 45.5 52.4 10 41.7 48.2 15 37.7 43.2 20 34.3 39.8 30 31.2 35.9 Table 1 Minimum Permanent Free Opening, Square Inches for Factory Built Fireplaces Chimney Height (Feet) 18” Log Set 24” Log Set Minimum Opening (Square Inches) 10 35.3 44.2 15 26.4 32.2 20 22.1 26.4 25 18.1 22.9 30 17.3 20.4 35 15.9 18.9 40 15.2 18.1 Table 2 3 HOW TO INSTALL YOUR GAS LOG SET This log set must be installed by a qualified person and instructions must be followed exactly to ensure safe operation. Your log set is packaged in three (3) boxes. The complete burner assembly is packaged in one box and the logs are packaged in separate boxes. GENERAL INSTALLATION These logs require a minimum permanent free opening as stated in the chart on page 3 of these instructions, that must be provided ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría