Iniciar sesión:
Votos - 3, Puntuación media: 3.3 ( )

Manual de usuario Blue Rhino, modelo GBC750W-C

Fabricar: Blue Rhino
Tamaño del archivo: 9.55 mb
Nombre del archivo: 60e90636-e50d-a9c4-add2-0ff835c2b340.pdf
Idioma del manual:enfr
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


For assistance call 1.800.762.1142 toll free. Please have your owner’s manual and serial number available for reference. For Easiest Assembly: • To avoid losing any small components or hardware, assemble your product on a hard level surface that does not have cracks or openings. 2 Attach Front Frame Support E x 2Jx 2 Kx 2 1 Install Casters 5 Attach LP Gas Tank Shield Ax 4 6 Attach Grill Body Dx 4 Kx 4 Jx 4 9 Install Grease Tray 10 Attach Tool Holder Cx 2 Jx 2 Kx 2 14 Attach Side Shelves 13 Assemble Right Side Shelf Bx 3 Assembly Instructions (continued) 11 Attach Left Side Shelf Panel Bx 3 12 Assemble Right Side Shelf Panel Ax 1 Hx 1 Bx1 Ix 1 16 Secure Right Side Shelf Assembly Bx 1 Fx 2 15 Secure Left Side Shelf Assembly Bx 1 Fx 2 17 Attach Hose Clip Cx 1 18 Secure Left Side Shelf Assembly 2 Cx 1 22 Attach Grease Cup and Grease Cup Support 21 Insert Cooking Grid and Warming Rack Assembly Instructions (continued) 19 Attach Side Burner Ignitor Wire 20 Insert Heat Plates 23 Insert Battery Lx 1 Installing LP Gas Tank To operate you will need (1) precision-filled standard grill LP gas tank (20#) with external valve threads. Note: An empty standard grill LP gas tank weighs approximately 18 lbs. A precision-filled standard grill LP gas tank should weigh no more than 38 lbs. Insert LP Gas Tank Place precision filled LP gas tank upright into hole in grill body so it is arranged for vapor withdrawal. Secure LP Gas Tank Secure tank by sliding tank retainer wire over shoulder of LP gas tank. Connect LP Gas Tank Before connecting, be sure that there is no debris caught in the head of the LP gas tank, head of the regulator valve or in the head of the burner and burner ports. Connect gas line to tank by turning knob clockwise until it stops. Disconnect LP Gas Tank Before disconnecting make sure the LP gas tank valve OFF. Disconnect gas line to tank by turning knob counterclockwise until it is loose. Need a tank of gas? Try tank exchange service. It’s easy, fast, safe, and available at tens of thousands of conveniently located retail outlets nationwide. You can purchase a new full tank or exchange your empty for a precision filled one. Operating Instructions Checking for Leaks Burner Connections Make sure the regulator valve and hose connections are securely fastened to the burner and the tank. If your unit was assembled for you, visually check the connection between the burner pipe and orifice. Make sure the burner pipe fits over the orifice. WARNINGFOR YOUR SAFETY: Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause death, serious bodily injury, or damage to property. Please refer to diagram for proper installation. If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for assistance. Tank/Gas Line Connection Make 2-3 oz.a of leak solution by mixing one part liquid dishwashing soap with three parts water. Make sure control knobs are off. Turn LP gas tank ON at valve. Spoon leak check solution at all “x” locations If any bubbles appear turn LP gas tank OFF, reconnect and re-test. If you continue to see bubbles after several attempts, disconnect LP gas source and contact 1.800.762.1142 for assistance. If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed. Operating Main Burners Lighting 1. Open lid. Attempting to light the burner with the lid closed may cause an explosion! 2. Make sure there are no obstructions of airflow to the gas unit. Spiders and insects can nest within and clog the burner / venturi tube at the orifice. A clogged burner tube can lead to a fire beneath the appliance. 3. All control knobs must be in the OFF position. 4. Turn on gas at LP gas tank. 5. Push and turn control knob c ounterclockwise to HIGH. 6. Press the electronic igniter button and hold for 5 seconds to light burner. 7. If ignition does not occur in 5 seconds, turn burner control knob OFF, wait 5 minutes, and repeat lighting procedure. 8. If igniter does not light burner, use a lit match secured with the lighting rod provided to light burners manually. Access the burners through the cooking grid and heat plates. Position the lit match near side of the burner. Important: Always use the lighting rod provided when lighting burners with a match. 9. After lighting, observe the burner flame, make sure all burner ports are lit and flame height matches illustration. CautionIf burner flame goes out during operation, immediately turn the gas “OFF” and open lid to let the gas clear for about 5 minutes before re-lighting. LP Gas Connection Burner venturi LP Gas Valve with Orifice Main Burners LP Gas Connection LP Gas Valve with Orifice Burner venturi Side Burner XXXXX LP Gas Tank Valve Control Knob Main Burner Lighting Rod Placement Slight Yellow Flame Slight Blue Burner Dark Blue Main burner proper flame height. 3. Keep the ventilation opening(s) of the LP gas tank area free and clear from debris. 4. Visually check the burner fl...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría