Iniciar sesión:
Votos - 2, Puntuación media: 3 ( )

Manual de usuario Broilmaster, modelo P4

Fabricar: Broilmaster
Tamaño del archivo: 702.6 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


WARNING: DO NOT INSTALL OR OPERATE THIS GRILL WHERE GASOLINE OR OTHER FLAMMABLE MATERIALS ARE USED OR STORED. FAILURE TO COMPLY WITH THIS WARNING COULD RESULT IN EXPLOSION OR FIRE CAUSING PROPERTY DAMAGE OR PERSONAL INJURY. Gas Type Never use Liquid Propane (LP) gas with a grill designed for Natural gas, or Natural gas with a grill designed for Liquid Propane gas. The type gas required for your grill can be determined from the product identification label located on the grill’s control panel. Questions regarding different types of gases should be directed to your gas supplier. Cylinder Requirements YouR Broilmaster® Premium Gas Grill requires a standard twenty (20) pound propane gas cylinder. The maximum height allowable for a replacement cylinder is approximately twelve (12") inches . (30.5centimeters) The propane gas cylinder used must be: 1. constructed and marked in accordance with the specifications for LP gas cylinder of the U.S. Department of Transportation (D.O.T.) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres, and Tubes for Transportation of Dangerous Goods; and Commission as applicable. 2. provided with a listed overfilling protection device (OPD). 3. provided with a listed safety device having direct access with the vapor space of the cylinder and the cylinder supply system must be arranged for vapor removal. 4. provided with a shutoff valve terminating in a valve outlet as specified in the Standard for Compressed Gas Cylinder Outlet and Inlet Connections, ANSICGA-V-1. 5. provided with a plug to effectively seal off the cylinder outlet when the cylinder is being stored or transported. 6. provided with a collar to protect the cylinder valve. CAUTION: DO NOT USE A PROPANE GAS CYLINDER WHICH HAS A CAPACITY GREATER THAN TWENTY (20) POUNDS WITH THIS GRILL AND SIDE BURNER. Page 12 P3, P4 PROPANE GAS GRILLS PROPANE GAS GRILLS Propane Cylinder Safety Liquid Propane (LP) gas has a long history of safe use when the safety precautions provided in this manual are followed. FAILURE TO FOLLOW THESE SAFETY PRECAUTIONS COULD RESULT IN A FIRE OR EXPLOSION CAUSING PROPERTY DAMAGE OR PERSONAL INJURY. Propane gas cylinders should always be handled, stored, and transported with extreme caution in a secured upright position. Never attempt to use or repair a propane gas cylinder that has been damaged. Never attempt to use or repair a cylinder with a faulty or damaged valve outlet. A cylinder that has been dropped, dented, or otherwise damaged must be replaced. A propane gas cylinder should never be transported in the passenger area of a vehicle. Keep cylinders out of direct sunlight and never apply any other source of direct heat to them. When refilling your cylinder, always insist on a reputable, qualified gas dealer. Your propane gas cylinder is filled by weight, and should never exceed eighty (80%) percent of its weight limit. If the cylinder is not completely empty, the gas dealer must make necessary adjustments to ensure it is not overfilled. Never use an overfilled Propane gas cylinder. Cylinder Storage Your grill must be stored outdoors in a well ventilated area if the cylinder is attached to it. Disconnected cylinders must have a threaded valve plug tightly installed and must not be stored in any building, garage, or other enclosed area. Flammable materials (gasoline, grill covers, etc.) must not be stored in the cylinder enclosure. Always store Propane cylinders in a secured upright position, out of the reach of children. Connection Requirements CAUTION: NEVER USE LIQUID PROPANE (LP) GAS IN A GRILL DESIGNED FOR NATURAL GAS, OR NATURAL GAS IN A GRILL DESIGNED FOR LIQUID PROPANE GAS. QUESTIONS REGARDING DIFFERENT TYPES OF GASES SHOULD BE DIRECTED TO YOUR LOCAL GAS SUPPLIER. Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1. In Canada, installation shall be in accordance with CAN/CGA-B149.2 Propane Installation Code, or CAN/CGA-B149.1 Natural Gas Installation Code, and local codes where applicable. Consult your local gas supplier or propane gas dealer for code regulations and recommended procedures. WARNING: BROILMASTER® PREMIUM GAS GRILLS REQUIRE LIQUID PROPANE (LP) CYLINDERS EQUIPPED WITH AN OVERFILL PROTECTION DEVICE (OPD). AN OVERFILLED OR IMPROPERLY FILLED PROPANE CYLINDER CAN BE DANGEROUS. Always use the pressure regulator and hose assembly supplied with your Propane gas grill. Note: Not all valve and cylinder combinations are compatible. Check warning tag on valve and cylinder as well as external fitting threads. All Broilmaster® pressure regulators and hose assemblies require Propane cylinders with a Type 1 connection device as illustrated. FIGURE 19. FIGURE 19 P3, P4 Page 13 PROPANE GAS GRILLS PROPANE GAS GRILLS Pressure Regulator and Hose Assembly The pressure regulator has an outlet pressure of not more than eleven (11”) inches water column. It must be connected to the Propane gas cylinder’s female valve outle...

Otros modelos de este manual:
Greeley - P3 (702.6 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría