Iniciar sesión:
Votos - 4, Puntuación media: 3.5 ( )

Manual de usuario Weil-McLain, modelo Gas Burner

Fabricar: Weil-McLain
Tamaño del archivo: 116.39 kb
Nombre del archivo: 97eaad77-9791-41b5-9615-bfd8e38dcfd5.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


t C. JX t 3.13 ' I I X 5/8 Dia., 4 holes -f"" : ; “[Mul; ,t I X c(r) I B(R) F E Note: Add .38 to "H" dim for size of opening in boiler front plate. Burner Model Number A B(R) C(R) D E F* G H I S X Approximate Weight WCR1 34.13 5.56 14.50 4.63 12.25 20.00 3.25 7.25 7.38 12.63 7.25 175-200 WCR2 39.13 6.13 14.00 5.25 14.00 20.00 4.00 8.75 8.50 13.38 8.50 220-300 WCR3 44.00 7.00 15.25 6.00 16.00 22.38 5.00 10.13 11.50 15.50 10.00 360-400 WCR4 50.00 7.31 17.69 7.00 18.50 28.00 6.00 12.13 14.25 19.13 12.00 500-550 * Required for installation of standard control components Part No. 550-142-029/0508 Weil-McLain 88 Water and Steam Boilers — Series 2 — For Gas, Light Oil, & Gas/Light Oil-Fired Burners Burner specifications and settings Table 1 Burner data Boiler Model Number Burner Input Positive Pressure In Firebox In. W.C. Standard Burner Model Designation Standard Combustion Control Standard Control System Burner Motor 3450 Rpm Standard Motor Voltage No. 2 Oil Gph Gas Mbh Gas Light Oil Gas/Light Oil Gas Light Oil Gas/Light Oil Gas Light Oil Gas/Light Oil Gas Light Oil Gas/ Light Oil 488R 6.9 996 0.80 WCR1-G-12 WCR1-OS WCR1-GO-12 RM7897A R7184P RM7897C OO FALFS OO/FALFS '/2 '/2 '/2 120/60/1 488 7.0 1,010 0.80 WCR1-G-12 WCR1-OS WCR1-GO-12 RM7897A R7184P RM7897C OO FALFS OO/FALFS '/2 '/2 '/2 120/60/1 588 9.4 1,356 0.58 WCR1-G-12 WCR1-OS WCR1-GO-12 RM7897A R7184P RM7897C OO FALFS OO/FALFS '/2 '/2 120/60/1 688 11.8 1,701 0.46 WCR2-G-15 WCR2-OAS WCR2-GO-15 RM7897A R7184P RM7897C LHO LHO LHO/LHO '/2 % % 120/60/1 788 14.2 2,046 0.47 WCR2-G-15 WCR2-OAS WCR2-GO-15 RM7897A R7184P RM7897C LHO LHO LHO/LHO '/2 % % 120/60/1 888 16.6 2,382 0.49 WCR2-G-20A WCR2-OBS WCR2-GO-20A RM7897A R7184P RM7897C LHO LHO LHO/LHO % 1 1 240/60/1 988R 17.2 2,482 0.50 WCR2-G-20B WCR2-OBS WCR2-GO-20B RM7897A R7184P RM7897C LHO LHO LHO/LHO 1 1 1 240/60/1 988 18.8 2,737 0.50 WCR2-G-20B WCR2-OBS WCR2-GO-20B RM7897C R7184P RM7897C LHO LHO LHO/LHO 1 1'/2 1'/2 240/60/1 1088R 20.0 2,887 0.52 WCR2-G-20B WCR2-OBS WCR2-GO-20B RM7897C RM7897A RM7897C LHO LHO LHO/LHO 1 1'/2 1'/2 240/60/1 1088 21.5 3,082 0.73 WCR3-G-20 WCR3-O WCR3-GO-20 RM7897C RM7897A RM7897C LHO LHO LHO/LHO 1'/2 2 2 240/60/1 1188 23.5 3,428 0.53 WCR3-G-20 WCR3-O WCR3-GO-20 RM7897C RM7897A RM7897C LHO LHO LHO/LHO 1'/2 2 2 3-Phase* 1288 26.0 3,773 0.48 WCR3-G-20 WCR3-O WCR3-GO-20 RM7897C RM7897A RM7897C LHO LHO LHO/LHO 1'/2 2 2 3-Phase* 1388 28.5 4,119 0.56 WCR3-G-25 WCR3-O WCR3-GO-25 RM7897C RM7840L RM7840L LHO LHO LHO/LHO 1'/2 2 2 3-Phase* 1488 31.0 4,464 0.58 WCR3-G-25B WCR3-OB WCR3-GO-25B RM7840L RM7840L RM7840L LHO LHO LHO/LHO 3 3 3 3-Phase* 1588 33.0 4,809 0.59 WCR3-G-25B WCR3-OB WCR3-GO-25B RM7840L RM7840L RM7840L LHO LHO LHO/LHO 3 3 3 3-Phase* 1688R 34.5 4,979 0.80 WCR3-G-25B WCR3-OB WCR3-GO-25B RM7840L RM7840L RM7840L LHO LHO LHO/LHO 3 3 3 3-Phase* 1688 35.5 5,155 0.80 WCR3-G-25B WCR3-OB WCR3-GO-25B RM7840L RM7840L RM7840L LHO LHO LHO/LHO 3 3 3 3-Phase* 1788 38.0 5,494 0.62 WCR4-G-25 WCR4-OA WCR4-GO-25 RM7840L RM7840L RM7840L LHO LHO LHO/LHO 3 5 5 3-Phase* 1888 40.5 5,845 0.69 WCR4-G-25 WCR4-OA WCR4-GO-25 RM7840L RM7840L RM7840L LHO LHO LHO/LHO 3 5 5 3-Phase* * 208/60/3, 240/60/3, 480/60/3 burner motor voltage must be specified. Notes for Table 1 and Table 2 1. Burner capacities listed for elevations up to 2,000 feet. For higher elevations, consult local Weil-McLain distributor/agent or sales office. 2. Light oil ratings based on No. 2 fuel oil with heating value of 140,000 Btu per gallon. 3. Gas ratings based on natural gas with heating value of 1,000 Btu per cubic foot and specific gravity of 0.60. Gas burners for other gases are available. Consult local Weil-McLain distributor/agent or sales office. 4. Boiler-burner unit to be adjusted to achieve +0.10 inches W.C. pressure at the flue collar, resulting in positive pressure in firebox as listed. 5. Minimum gas pressures listed are subject to variations due to job conditions. Gas burners for other gas pressures are available. Consult local Weil-McLain distributor/agent or sales office. 6. Tee pressures shown are for initial start-up. Final pressure should be determined after checking actual gas flow and combustion readings. 7. 120/60/1 control circuit is used for all burners. 8. Control circuit transformer is available as an option. 9. Motor relay or contactor will be furnished for all units, except 488R and 488. 10. Airflow safety switch is standard for all gas and combination gas/light oil units. 11. Burners will be completely assembled and wired (except gas train) and factory test-fired. 12. Burners listed by Underwriters Laboratories, Inc., state of Connecticut, Fire Marshal state of Massachusetts, city of New York MEA, and others. 13. Special controls can be provided to meet other code requirements not listed. Consult your local Weil-McLain distributor/agent or sales office. 14. Electric gas pilot will be furnished as standard e...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría