Disconnect the power from the opener before removing cover and cutting the jumper. MAKE SURE YOU DISCONNECT THE POWER BEFORE CUTTING THE JUMPER. THE RUN TIMER WILL NOT CHANGE IF THE JUMPER IS CUT WITH THE POWER CONNECTED. This jumper is located under operator cover on the control board, as illustrated. 110057-2 Cut and Separate IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH, READ AND FOLLOW ALL INSTRUCTIONS! • Ensure authorized personnel only operate the door. NEVER let children operate or play with door controls. Keep the Remote Control away from children. • ALWAYS keep a moving door in sight and keep people and objects away from the door areauntil the door is completely closed. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR. • TEST THE DOOR OPENER MONTHLY. The door MUST reverse upon contact with a 1-1/2” high object (or a 2 X 4 board laid flat) on the floor. After adjusting the sensitivity or the limit of travel, ALWAYS RETEST the Opener. Failure to ADJUST THE OPENER PROPERLY may result in SERIOUS INJURY OR DEATH. • If possible, USE THE MANUAL RELEASE only when the door is closed. Use caution when using the Release with the door open. WEAK OR BROKEN SPRINGS MAY ALLOW THE DOOR TO CLOSE RAPIDLY, CAUSING SEVERE INJURY OR DEATH. • KEEP THE GARAGE DOOR PROPERLY BALANCED. See the door owner's manual. An improperly balanced door MAY CAUSE SEVERE INJURY OR DEATH. Have a QUALIFIED SERVICE PERSON MAKE REPAIRS TO CABLES, SPRING ASSEMBLIES AND OTHER HARDWARE. • SAVE THIS INSTRUCTION MANUAL. 17 18 F: OPERATING INSTRUCTIONS OPERATION OF YOUR OPENER HOW TO ACTIVATE THE OPENER Never let children operate or play with the door controls. Keep Remote Control Away for Children. Use any of the following devices: 1. The Remote Control Transmitter. Hold the push button down until the door starts to move, then release button. 2. The Door Control Button. Momentary push of the button until the door starts to move. Constant push of the button until the door is closed is required if light flashes. 3. An Outside Keylock or Keyless Entry System (if you have installed either of these options, see Mfg’s instructions). HOW THE DOOR MOVES WHEN THE OPENER IS ACTIVATED Always keep moving door in sight and away from people and objects until it is completely closed NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR. IF THE DOOR IS... ...FULLY OPEN, then pushing the standard wall Push Button or the radio control will cause the door to begin MOVING DOWNWARD. ...FULLY CLOSED, then pushing the wall Push Button or the radio control will cause the door to begin MOVING UPWARD. ...MOVING UPWARD, then pushing the wall Push Button will cause the door to STOP. The next push of the wall button will cause the door to begin MOVING DOWNWARD (Alternate Action Operation). ...MOVING DOWNWARD, then pushing the wall Push Button or the radio control will cause the door to STOP. The next activation will cause the door to BEGIN MOVING UPWARD. ...MOVING DOWNWARD and an obstruction is encountered, the door will STOP, PAUSE AND REVERSE TO THE OPEN DIRECTION. ...MOVING UPWARD and an obstruction is encountered, the door will STOP. The next activation will CLOSE the door. The SAFE FINISH PHOTOELECTRIC uses an invisible beam which, when broken by an obstruction, causes a closing door to open and prevents an open door from closing. HOW THE LIGHT WORKS AND WHAT IT MEANS WHEN IT FLASHES 1. The convenience light automatically turns on when the opener is activated and remains on for 4-1/2 minutes for your convenience and safety. 2. The light will flash after coming upon an obstruction in the down direction to alert you of a problem. It will continue to flash for 4-1/2 minutes, then shut off. 3. Optional Wall Station adds the convenience of allowing the light to be turned on and stay on until turned off by a second push of the button or activation of door cycle. If the light begins to flash and the door does not move in the close direction from a push button or radio, the external safety device (Safe Finish Photoelectric) is activated or defective (misaligned or blocked etc.). To temporarily override and close door, activate pushbutton or wall station for 2 seconds; opener will begin moving in the down direction. The button must remain depressed until the cycle is completed. If the button is released before cycle is completed, the door will reverse and come to a fully open position. Problems with the safety system should be inspected by a professional garage door installer. F: OPERATING INSTRUCTIONS HOW TO OPERATE THE DOOR MANUALLY -MANUAL RELEASE DISCONNECT The door should be fully closed, if possible, before using the manual disconnect. Weak or broken springs could allow an open door to fall rapidly. Property damage or serious personal injury could result. Do not use the manual release handle to pull the door open or closed. Your opener is equipped with a manual release recessed trolley-type disconnect system, enabling manual operation of the gara...