Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario Vitek, modelo VT-6402 BK

Fabricar: Vitek
Tamaño del archivo: 1.19 mb
Nombre del archivo: Vitek-VT-6402_BK-Pdf-Rus.Pdf
Idioma del manual:ruuken
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Continuous LCD backlight, and continuous projection of time is possible only in case of connection to external power source through AC adapter. Replacing Batteries On appearance of adequate icon indications displaying that the batteries are down replace remote sensor batteries. Get Started By first startup, switch main block on, and switch on remote sensor. Set data transfer channel by channel switcher «1-2-3» located on remote sensor. Hold button CHANNEL on main block, you will hear sound signal. Main block starts searching remote sensor signal. Press button Tx to reset the sensor. When connection between sensor and main block is set on, temperature indications from remote sensor will appear on LCD. Setting pressure parameters by switching on the unit first time 1. After connecting basic block to power supply line pressure units’ icon starts blinking. Use buttons «▼/▲»to select pressure units, inHg, hPa, mBar or mmHg. Press button PRESSURE for confirmation. 2. Use buttons «▼/▲» to set the value of altitude above sea level. Press button PRESSURE for confirmation. Setting pressure parameters via first startup is imperative for precise weather forecast. 6 16:37:16 6402IM.indd 7 English Symbolic weather forecast Weather forecast is composed according to atmosphere pressure time history. Based on acquired data weather station is able predicting weather for the next 12-24 hours. sunny partly cloudy cloudiness rain storm warning Predictions accuracy: 70%; prediction of the considerable weather changes (for example, from sunny weather to rain) is more accurate then prediction of negligible weather changes (from partly cloudy to cloudiness). Weather station predicts possible weather, thus symbols could not agree with current weather. Forecast: SUNNY for night means cloudless sky. For more precise weather forecast it is required setting altitude above sea level. Use buttons «▼/▲» to choose pressure units. Press button PRESSURE for confirmation. Use buttons «▼/▲» to set altitude above sea level. Press button PRESSURE for confirmation. Attention! If your weather station is indicating “rain” or “storm warning” for a long time, and this indications do not comply with the real situation, try changing altitude above sea level gradually (in 20 meters/60 feet range) until the weather station indications get in accordance with real weather conditions. Increasing altitude above sea level Decreasing altitude above sea level 7 16:37:16 02IM.indd 8 English Temperature indications Basic block is able receiving data from tree remote sensors, each of them has each own channel for temperature data transmission. Centigrade or Fahrenheit degree can be selected as temperature units. Use C/F to select temperature units. Switching between data receiving channels Press button CHANNEL to switch between remote sensors’ data receiving channels (Ch 1, Ch 2, Ch 3), indoors (IN), switching between different channels’ temperature data indication (CV) in cycle. Temperature trends Temperature trends are displayed by arrows (increasing, decreasing) near the adequate data. Viewing minimal/maximal value of temperature Each pressing on button MEMORY switches between the next parameters’ indication: • Current temperature • Minimal temperature • Maximal temperature Minimal/maximal temperature values reset Press and hold button MEMORY for 3 seconds to clear all channels’ memories. Notice: Remote sensor batteries voltage may decrease while operating at temperature below 0°C, thus remote sensor range of action would be shortened too. Setting date and current time Basic block is able viewing current time and date. Press button CLOCK to switch between current time, date and day of week. Press and hold button CLOCK for 3 seconds to set current time and date. You can choose time indication format (12 hours or 24 hours) and date format (day/ month or month/day), set current time (hours, minutes) and date. Use buttons «▼/▲» to input parameters. Press button CLOCK for confirmation. Setting alarm Press button ALARM to switch on alarm mode. Symbol «AL» appears on LCD. Press this button once more to switch alarm ON/OFF, when alarm is on symbol ^ is on LCD. 8 16:37:16 6402IM.indd 9 English Pre button ALARM for more then 3 seconds to set alarm time. Alarm hours digits start blinking. Use buttons «▼ /▲» to set alarm hours digits. Press button ALARM for confirmation. Alarm minutes digits start blinking. Use buttons «▼/▲» to set alarm minutes digits. Press button ALARM for confirmation. Alarm sound signal repeat Alarm signal could be switched off for 10 minutes by pressing button SNOOZE/ LIGHT. Symbols «Zz» are displayed on LCD. After 10 minutes alarm signal will be repeated. Press ALARM button to switch alarm off. Switching backlight off Set switcher Backlight into position ON/OFF or press button SNOOZE/LIGHT (for short LCD backlight) to put on/off LCD backlight. Set switcher Light Bar into position ON/OFF to put on...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría