Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Sony, modelo ICD-SX700

Fabricar: Sony
Tamaño del archivo: 6.16 mb
Nombre del archivo: 4127580131.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


. By attaching a tripod (not supplied) using the stand, you can adjust the angles of the IC recorder and the built- in microphones more precisely. Getting Started GB source. source. Approx. 2 to 3 m Place the IC recorder with its display window facing upward and the built-in microphones pointing at the sound Tripod (not supplied) Recording dictation (using the voice recognition software) . Set “REC LEVEL” to “LOW ”in the menu (page 33). . Slide the DIRECTNL switch to “ON” to record a voice coming from a specific direction (page 29). . To transcribe a message recorded on the IC recorder using voice recognition software (not supplied), set “REC MODE” to the LPCM, MP3 or LPEC (except LP) mode (page 30). Microphone . Before you can transcribe recorded messages, you have to create a user file specifically adapted to the sound of your recorded speech. This procedure is called “training.” For details on “training,” refer to the help files supplied with the voice recognition software you are using. GB . .o obtain maximum recognition accuracy, hold the IC recorder so that the microphone is about 2 -3cm from the corner of your mouth. . To minimize the sound of your breath in the recordings, do not hold the microphone directly in front of your mouth. . To obtain maximum recognition accuracy, avoid recording in a noisy place. . You cannot transcribe a message recording the voices of more than one person. Turning the IC Recorder On or Off Getting Started WhenyouarenotusingtheICrecorder, youcanpreventthebatteriesfromgettingweakquicklybyturningthepoweroff. GB Turning the power off Turning the power off e the HOLD switch in the direction of the arrow in the stop mode. “HOLD” with the key mark and the current time is displayed, then “POWER OFF” is displayed. The IC recorder turns off within a few seconds. Turning the power on Slide the HOLD switch in the opposite direction from that of the arrow. The IC recorder turnes on, and an accessing animation is displayed. .Tips . When you are not going to use the IC recorder for a long time, we recommend to turn off the IC recorder. . When about 10 minutes have passed after you have turned on the IC recorder and left it without doing anything, the display goes off automatically. (Press any button to show the display.) GB Recording Recording s Built-in directional microphone Built-in stereo microphones Operation indicator .(headphone) jack . . .. ., . /MENU DIRECTNL HOLD Recording 1 Select a folder. .Press /MENU to display the folder selection window. .Press .or .to select the folder in which you want to record messages, then press ... 2 Start recording. .Press .(record/pause) in the stop mode. The operation indicator lights in red. (When“LED” is set to“OFF” in the menu (page 91), the operation indicator does not light.) You do not need to press and hold .(record/pause) while recording. GB The new message will be automatically recorded after the last recorded message. .Speak into the built-in microphones. 3 Press .(stop) to stop recording. The IC recorder stops at the beginning of the current recording. .Tips . Before you start recording, we recommend you make a trial recording first. . When you purchase the IC recorder, there are 5 folders already available, and you can record up to 999 messages in each folder. . You can make new folders or delete unwanted folders using the supplied Digital Voice Editor software (page 101). . While recording, you can lock all the functions of all the buttons so that you can prevent inadvertent operations, by sliding the HOLD switch in the direction of the arrow. .Notes . You cannot record a message in a folder transferred from a computer. If you press .(record/pause) when you have selected a folder, the folder will be automatically switched to a folder in which a message can be recorded, and the message will be recorded as the last one in the folder. . While the operation indicator is flashing or is lit in red or orange, do not remove the batteries or connect or disconnect the USB AC adaptor. Doing so may damage the data. . Noise may be recorded if an object, such as your finger, etc., accidentally rubs or scratches the IC recorder during recording. . Before making a recording, be sure to check the remaining power of the batteries (page 16). . When“REC LEVEL”is set to“LOW ,”“HIGH ,” “S-HIGH ,”or “MUSIC ,”the limiter function does not work. . To avoid replacing batteries during a long recording session, use a USB AC adaptor (not supplied) (page 125). . The maximum recording time varies if you record messages in different recording modes. GB Recording To Do this pauserecording* Press.(record/pause). Duringrecordingpause,theoperationindicatorflashesinredand““flashesinthedisplaywindow. releasepauseandresumerecordingPress.(record/pause) again. Recordingresumesfromthatpoint.(Tostoprecordingafterpausingrecording,press.(stop).) reviewthecurrentrecordinginstantly** Press... Recordingstopsandplaybackstartsfromthebeginningofthemessagejustrecorded. reviewduring...

Otros modelos de este manual:
Dictado - ICD-SX800 (6.16 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría