Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Brita, modelo 1200

Fabricar: Brita
Tamaño del archivo: 2.15 mb
Nombre del archivo: ef95e80b-281e-4024-842f-f5beeb32785c.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


In the BRITA PURITY 1200 Clean calcium and magnesium ions are selectively removed from the drinking water via an ion exchanger using the fl ow method. This prevents residues on the dishes during drying due to carbonate hardness and scale deposits on important machine parts. This means that the dishwashers have a greatly increased service life. Furthermore, BRITA PURITY 1200 Clean Extra guarantees elimination of all salts in the water by means of full demineralisation of the tap water, preventing them from being deposited on glasses and cutlery. 2.2 Guarantee Provisions The PURITY 1200 Clean and PURITY 1200 Clean Extra fi lter systems are subject to the statutory guarantee of 2 years. A guarantee claim may be asserted only if all instructions in this Handbook are followed and observed. 2.3 Storage / Transport Adhere to the ambient conditions in the Technical Data (Chapter10) for storage and transport. The handbook should be seen as part of the product and kept for the whole service life of the fi lter system and passed on to subsequent owners. 2.4 Recycling / Disposal By disposing of this product and its packaging in the correct manner you are helping to prevent potential negative impacts on people and the environment that could be caused by incorrect disposal. Comply with local regulations and bring the units to be disposed of to a proper recycling facility at the collection points provided. Exhausted fi lters are taken back by BRITA at the addresses listed on the back of the cover. 3 Operating and Safety Information 3.1 Qualifi ed Personnel Installation and maintenance of the fi lter system may be carried out only by trained and authorised personnel. 3.2 Correct Use The product can only be operated properly and safely if it is installed, used and serviced in the manner described in this Manual. 3.3 Liability Exclusion Installation must be carried out in accordance withthe instructions in this Manual. BRITA shall not be held liable for any damage, including subsequent damage, arising from the incorrect installation or use of the product. 3.4 Specific Safety Information • Only drinking water within the intake water temperature range listed in Chapter 10 may be used as intake water for the BRITA water fi lter system. No microbiologically impaired water or water of unknown microbiological quality may be used without appropriate sterilisation. • For reasons of flavour, the fi ltered water is not suitable for the preparation of food and drinks. • If there is an official requirement of boil tap water, decommission the fi lter system. When the requirement to boil water comes to an end, the fi lter cartridge must be replaced and the connections cleaned. • BRITA recommends that the fi lter system not be decommissioned for a long period. After stagnation times of over 4 weeks, the boiler should be fl ushed or a pre-rinse executed. Please also note the maximum usage period of the fi lter cartridge is 12 months (Chapter 6). • The fi lter system is not resistant to heavily concentrated cleaning agents (e.g. bleach, chlorinated solvents, heavy oxidants) and must not come into contact with them. • The fi lter system must not be opened or dismantled during operation. The fi lter cartridge must not be opened. • The pressure vessel and pressure vessel lid of the fi lter system are designed for a service life of 10 years (from the date of installation). They must be replaced after 10 years. The hoses must be replaced in rotation after 5 years. • Production date. Production code sticker filter cartridge and packaging - Example: B715002010 7 Production year, here: 2007 15 Production week, here: calendar week 15 002 Batch No. filter medium, here the second batch filled in terms of quantity 010 Serial number of the filter cartridge, here the tenth cartridge from the second batch Production code sticker connector head - Example: 7102 XX 7 Production year, here: 2007 10 Production week, here: calendar week 10 2 Production day from Monday (1) to Friday (5), here: Tuesday xx Internal code Production date pressure vessel and pressure vessel lid - Example: 0307 03 Production month, here: March 07 Production year, here: 2007 3.5 Technical Safety Assembly Instructions • The terminal device operated with the fi lter must be free of limescale prior to installation. ! Caution: No water softening system may be operated upstream from the fi lter system. • Protect the fi lter system from sunlight and mechanical damage. Do not assemble near sources of heat and open fl ames. • A stop valve must be installed before the fi lter system intake hose. • If the water pressure is higher than 6 bar, a pressure reducer must be installed before the fi lter system. • A non-return valve tested by the DVGW has been factory-installed at the water intake of the fi lter head. • No copper pipes and no galvanised or nickel-plated pipes/connectors may be installed between the water fi lter and the consumer. The use of Brita hose sets is recommended here. When choos...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría