Insert the u-clip into the two square holes at the bottom rear of the manifold and push up to release the filter housings. Remove the housings with a downward twisting pull. 6. Remove the particle filter cartridge and the activated carbon cartridge and discard. If the RO membrane filter will be reused, clean the outside with a wet paper towel and place the membrane filter in a clean, unused plastic bag. 7. Wet some paper towels with the diluted bleach solution. Clean the inside of the housings and the underside of the manifold with the paper towels. SANITIZING THE STORAGE TANK AND FAUCET 1. Add 15 ml (about one tablespoon) of bleach to the particle filter housing (#1, Fig. 3). Replace all three housings on the manifold and insert the u-clips. 2. Turn on the supply valve and fill the storage tank with 1 to 2 gallons of water. NOTICE: The weight of the storage tank will increase by 8 to 16 pounds. Turn off the water supply valve. 3. Wait ten minutes before opening the faucet and draining the storage tank. Do not rinse any remaining solution from the tank. NOTICE: During this time, proceed to the .Sanitizing the Manifold Assembly. section. Wait to do step 4 until indicated. 4. Remove the temporary tubing connector and replace it with a new polishing filter. Make sure the flow arrow on the polishing filter points to the faucet (Fig. 4). SANITIZING THE MANIFOLD ASSEMBLY 1. Using the flat-blade screwdriver, pull the u-clips from all three housings. Insert the u-clip into the two square holes at the bottom rear of the manifold and push up to release the filter housings. Remove the housings with a downward twisting pull. Discard any solution remaining in the housings. 2. Open the particle filter cartridge bag half way, being careful not to touch the filter element. Lubricate the particle filter cartridge o-rings with water and insert the cartridge into position #1 in the manifold. 3. Fill housing #1 about 2/3 full of the diluted bleach solution from the 1-gallon container. Assemble the housing to the manifold and replace the u-clip. 4. Repeat steps 2 and 3 for housing #2 (activated carbon cartridge) and housing #3 (RO membrane filter). NOTICE: For RO membrane filters that have a single open-end, pour diluted bleach solution into the center tube. CAUTION: The solution should remain in contact with the RO membrane filter for at least five (5) but no longer than ten (10) minutes. Longer contact time will shorten the life of the membrane. NOTICE: While waiting for the filters to be sanitized, complete step 4 of the .Sanitizing the Storage Tank and Faucet. section. Then complete step 5 below. 5. Using the #2 Phillips screwdriver, loosen the capillary assembly retaining screws, then twist and remove the assembly. Inspect the tubing for plugging and kinks and replace the tubing as needed. Reinstall the capillary assembly, but leave the screws .-turn loose. Servicing Your System (cont.d) 6. In this step, you will need to observe water flowing to the drain. If the drain flow is not visible with the current tubing connections, install a temporary drain tube in the waste port of the manifold. Turn on the supply valve. When water is seen flowing to the drain, carefully loosen the capillary tube assembly retaining screws until the flow to the drain increases. NOTICE: When the assembly is about 3/16. out of the manifold, the o-ring seal for the capillary tube is bypassed, but there should be no external leaks. 7. Rinse the manifold assembly for five minutes or until no chlorine is detected in the water passing to the drain. Tighten the capillary assembly retaining screws. 8. Check the performance of the system according to the procedure outlined in the .Performance and Technical Information. section of this manual. Replace the RO membrane if necessary. 9. Instruct the customer to discard the first glassful of water from the system to flush out any residual chlorine that might remain in the polishing filter tubing and faucet. The polishing filter will remove any chlorine remaining in the storage tank. 10.Record your service on the chart at the end of the Owner.s Guide. Parts List Item Description Part Number 1 Faucet -Chrome 01-0004-42 - White 01-0022-53 2 Polishing Filter 01-0000-79 3 Plastic Ball Valve 01-0027-85 4 Storage Tank - Std. 01-0050-95 - Medium 01-0047-76 - Large 01-0047-65 5 Activated Carbon Element 01-0125-80 6 Capillary Assembly 01-0090-27 7 Reverse Osmosis Membrane Element H-30 01-0074-02 8 Activated Carbon Element 01-0125-80 * Icemaker Tee - 1/4 x 1/4 x 1/4 01-0024-66 * Tubing, Blue - 1/4" O.D. 00-4021-84 * Good Water Sentry. Monitor 01-0039-45 * Aqua-Cleer® Booster Pump 01-0093-34 * Not Illustrated 13 Culligan® Aqua-Cleer® Good Water Machine. Service Log MODEL __________________SERIAL NO. ______________________________ DATE INSTALLED ___________________________________________________ FOR SERVICE CALL CULLIGAN AT: (____) ______________________________ DATE SERVICED FILTER(S) CHANGED SANITIZED PARTICULATE FILTER ...

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría