Iniciar sesión:
Votos - 3, Puntuación media: 4.7 ( )

Manual de usuario Everpure, modelo 327

Fabricar: Everpure
Tamaño del archivo: 1.4 mb
Nombre del archivo: 4f436e2a-261a-4dbd-a35c-c545a9447104.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


This machine has been manufactured in accordance with the safety standards of both Underwriter’s Laboratories and the Canadian Standards Association. To maintain this degree of safety and to continue to achieve the level of performance built into this machine, it is important that installation and maintenance be performed so as to not alter the original construction or wiring and that replacement parts are as specified in the Parts Manual. Your investment in this equipment will be protected by using this Operatos’s Guide and the Parts Manual in your operation, service and maintenance work. By following prescribed procedures, machine performance and safety will be preserved. Crane Merchandising Systems Parts and Support Parts: 1-800-621-7278 Service:1-800-628-8363 Initial Set-up Power Requirements This merchandiser requires power as shown in the following table. NOTE: Each merchandiser should have its own electrical circuit. This merchandiser is supplied with a service cord for the country of use and is terminated in a grounding type plug. The wall receptacle used for this merchandiser must be properly polarized, grounded, and of the correct voltage. Operating the merchandiser from a source of low voltage will VOID YOUR WARRANTY. Each merchandiser should have its own electrical circuit and that circuit should be protected with a circuit breaker or fuse conforming to local regulations. Voltage Check - Place the leads of a voltmeter across the LINE (LIVE) and NEUTRAL terminals of the wall receptacle. The voltmeter should indicate 110-130 volts ac for 120 volt, 60 Hz locations, or 220-240 volts ac for 230 volt, 50 Hz locations. Polarity Check - Place the leads of a voltmeter across the LINE (LIVE) and GROUND terminals of the wall receptacle. The voltmeter should indicate 110-130 volts ac for 120 volt, 60 Hz locations, or 220-240 volts ac for 230 volt, 50 Hz locations. Noise Potential Check - Place the leads of a voltmeter across the NEUTRAL and GROUND terminals of the wall receptacle. The voltmeter should indicate 0 volts ac. A measurement greater than 1.5-2.0 volts ac could result in problems for the merchandiser's electronic circuitry caused by electrical noise. Any deviation from these requirements could result in unreliable performance from your merchandiser. Water Requirements If your location has chemically softened water, one of the following steps is advised: •Have a non-softened supply line run to the merchandiser •Contact your local water filter supplier for information and suggestions Well water can also be used in the Cold Drink Center. However, you should have it checked for levels of carbonates and alkalies. Contact your water filter supplier if these values are relatively high. Water Pressure Minimum water pressure: 20 psi (138.0 KPa) at 1/2 gallon/minute Maximum water pressure: 80 psi (522.0 KPa) at 1/2 gallon/minute Supply Line Requirements Locate supply line at the rear of the merchandiser. Equip the line with a shut-off valve. Flushing Water Supply Line Flush the water supply line before connecting it to the merchandiser. A minimum of five gallons is usually required before connecting the merchandiser to the supply line. To avoid introducing possible water line contaminants into the merchandiser, DO NOT flush the merchandiser water system. Positioning The Merchandiser You can position this merchandiser anywhere in a bank of machines. It can even be placed on the end flush against a side wall. Leave enough room in front of the merchandiser for the door to move freely. BE SURE THE REAR OF THE MERCHANDISER IS AT LEAST 6" AWAY FROM THE WALL. THIS WILL ENSURE WARM MOIST AIR IS VENTED OUT OF THE MACHINE'S INTERIOR AND THE REFRIGERATOR CONDENSER FAN IS NOT OBSTRUCTED. NOTE This machine is only rated for installation in an indoor location. Final Installation 1.Connect the merchandiser to the water supply: a.You will need the following: •A coil of copper tubing with outside diameter of 3/8 inch (9.5 mm) or greater. The appropriate plastic tubing may be substituted. •A 3/8 inch (9.5 mm) flare nut. A 3/8 inch (9.5 mm) male flare is provided. b.Connect the merchandiser to your water supply. 2.Connect the merchandiser to the power source: Power to the merchandiser is controlled by the main power switch, located on the power panel. a.Make sure the main power switch is OFF. b.Connect the merchandiser’s power cord to your wall outlet. 3.Using a spirit level, level the merchandiser front to back and side to side. 4.Set up the menu assembly:SELECTIONINSERTINSERTASSHOWNVIEWAVIEWATHUMBSCREWDOORSLIDEDISPLAYASSEMBLY327p0001 a.Swivel the cup turrets away from the door. b.Remove the thumb screws as shown, and slide out the menu assembly. c.Install selection inserts as shown. 5.Reinstall the menu assembly in the reverse order of assembly. 6.Load the coin mechanism: a.Open the cabinet door and the monetary door. b.Insert coins into their respective tubes until each tube has been filled. c.Inspect the tubes for shingle...

Otros modelos de este manual:
Dispensers - 325 (1.4 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría