Manual de usuario Bunn, modelo JDF-2

Fabricar: Bunn
Tamaño del archivo: 285.05 kb
Nombre del archivo: 35303.0000.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


b) In a 5 second period, press and release the “Sanitize Switch” the number of times that you want the password set to (maximum of 10.) For example: If you want the password set to 3, press and release the “Sanitize Switch” 3 times in the 5 second period. Note: To reset password to “0” (no password) press and hold the “Sanitize Switch”, without either “Hidden Switch” pressed, for the 5 second period. When the password resets to “0”, the beeper will sound and the “Water” indicators will illuminate for approximately 2 seconds. c) Release the “Hidden Switch”. d) At the end of the 5 second period, the password will be confirmed by the “WATER” indicators flashing the password. e) From this point forward, the password must be entered before access is allowed to programming modes or the service lockout function. 35303 012703 16 ADJUSTMENT & OPTIONAL SETTINGS (cont) 3. To enter the password, proceed as follows: a) Press and hold either “Hidden Switch”. b) In a 5 second period, press and release the “Sanitize Switch” the password number of times. For example: If the password is set to 3, press and release the “Sanitize Switch” 3 times in the 5 second period. c) Release the “Hidden Switch”. d) Wait for the password to be confirmed by the flashing of the “Water” indicators. e) Enter the desired program mode or select service lockout as normal within the next 5 seconds. Note: If the program mode/service lockout is not selected within 5 seconds, it will be necessary to re-enter the password. 4. If the password is forgotten, it can be reset to “0” (no password) as follows: Note: The following procedure also clears the dispenser lockout password. f) Disconnect the dispenser from its power source. g) Place the “Refrigeration Switch” in the OFF (rearward) position. h) While pressing and holding the “Lock Switch”, connect the dispenser to its power source. i) Continue to hold the “Lock Switch” until the dispenser beeps three times, then release. j) The passwords are now returned to “0” (no programming or service lockout password/dispenser lockout disabled.) k) After 3 minutes, place the “Refrigeration Switch” in the ON (forward) position). 35303 012703 17 Dispense Fault List “REFILL” indicator Beeper Fault 2 flashes 2 beeps Dispense station locked out. 3 flashes 3 beeps DISPENSE/RINSE sensing fault. 4 flashes 4 beeps DISPENSE/RINSE knob mis-positioned. 5 flashes 5 beeps Pump motor stalled/speed sensor inoperative. All “REFILL” indicators flash 3 times 3 beeps Dispenser locked out. Cooling Fault List Fault Code “COOLING” indicator DBC display (optional) Fault Fault Priority 8 8 flashes every 5 seconds fault 8 Bath water level low. (Also lights all “WATER” indicators) 1 7 7 flashes every 5 seconds fault 7 Bath temperature probe short circuit. 2 6 6 flashes every 5 seconds fault 6 Bath temperature probe open circuit. 3 5 5 flashes every 5 seconds fault 5 Cabinet temperature probe short circuit. 4 4 4 flashes every 5 seconds fault 4 Cabinet temperature probe open circuit. 5 3 3 flashes every 5 seconds fault 3 Cooling system failure (disables all dispense functions) 6 0 On steady temperatures Bath/cabinet Bath and cabinet temperatures excessive. 7 2 2 flashes every 5 seconds Bath/cabinet temperatures Bath temperature excessive. 8 1 1 flash every 5 seconds Bath/cabinet temperatures Cabinet temperature excessive. (Disables all dispense functions, flashes, all REFILL and WATER indicators, and sounds the beeper when temperature is excessive for more than 6 hours.) 9 35303 012703 18 Dip Switch Function List Dip Switch Controls Off On 1 “REFILL” indicator when “concentrate out” is detected. Inactive Active 2 Lockout dispense components when “concentrate out” is detected. Inactive Active (Note) 3 Number of positions that can dispense/rinse simultaneously. 3 2 4 Rinse timer Off On 5 Audio feedback during dispenses. On Off 6 Future use. None None Note: When dip switch 2 is in the “on” position, the “REFILL” indicator is active, regardless of dip switch 1 position. 35303 012703 19 COOLANT SCHEMATIC DIAGRAM CONDENSER SUCTIONACCUMULATOR COMPRESSOREVAPORATORPROCESS TUBE FILTERDRYER 35303 012703 20 SCHEMATIC WIRING DIAGRAM GRN + J3-1 J3-2 J1-1 J1-5 J1-10 C O N T R O L P C B O A R D J1-18 J7-1 J7-5 J7-10 J7-16 J8-1 J8-8 J6-1 J6-6 J6-12 LAMP ASSY. GRNGRN NL1 BLU BRN/BLKRED/BLKRED/BLKGRYWHIBLKLIMIT THERMOSTAT K2 K2 COMP. COMPRESSOR ASSEMBLY – RECT TRANSFORMER WHI/BLUWHI WHI WHI WHI/RED WHI/RED BLK BLK RED/BLK RED/BLK GRY WHI WHI SOL #2 DISPENSE RED/BLKWHI/ORNSOL #1 DISPENSE #2 RINSE & DISPENSE LIMIT #1 RINSE & DISPENSE LIMIT RED/BLKWHI/VIO RECIR. PUMP WHI/GRYWHI/GRN WHI/GRN WHI/VIOORNWHI/ORNBRN/BLK J5-1J5-5J5-10J5-15J5-19 RINSE SOL WHI WHI/REDWHIBLKVIO J4-1J4-5J4-10J4-14 J9-1 J9-6 18 1 12 VIO WHI/ORN WHI/VIO GRY RED PNK WHT/VIO VIO VIO RED/BLK RED WHI/VIO WHI GRY RED WHI/RED RED BLK WHIBLK GRY WHI/ORN GRN/WHI GRN/BLK ORN/BLK WHI/BLK BLU/WHI BLK/WHI RED RED RED VIO GRY RED/BLK RED/WHI BEEPER SANITIZE SWITCH MOTOR CONDENSOR FAN BLKBRN/BLKBLU/BLK BL...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría