SPECIFICATION & PARTS IDENTIFICATION MODEL C12E (CHILLER) DIMENSION 410Wx210Dx290H(mm) WEIGHT 12.5kg COLD CONSUMPTION 120W TEMP CONTROL AUTO TANK Stainless Steel CAPACITY 5.0 l/h (10E) ELECTRICAL 220-240V, 50/60Hz. 110-127V, 50/60Hz. Check the available power supply against the watercooler data plate to assure correct electrical service. Siavd do NOIlONfld S NOIlVd3dO z J9SU0pUOQ jossejdmoQ >|UB} J0}BM Pl°0 yBddfl pjoo jaMOd jojoiu uej J0AOO UIEJQ )B)somjaq) J0}B№ p|OQ >13 va 1N О У d - dBD UjBJQ A. Cooling Operation The vapor refrigerants that compressed to high temperature & high pressure conditions in the compressor, turn into liquid refrigerant of high temperature and high pressure passing through the condenser, and then turn into the liquid refrigerants of low temperature and low pressure conditions by passing through the capillary tubes. The liquid refrigerant of low temperature & low pressure absorbs the surrounding heat while evaporating in the evaporator. Then, it is sucked in the compressor by turning into saturated vapor. B. Function of Parts ® Compressor: Compresses the vapor refrigerant sucked from the evaporator and discharges it to condenser © Condenser: Changes the compressed vapor refrigerant into the liquid refrigerant by cooling. © Drier: Removes moisture and dirt inside pipes ® Capillary tube: Reduces the pressure of liquid refrigerant and evaporates it in the evaporator under constant pressure. © Evaporator: Absorbs the surrounding heats while evaporating the liquid refrigerant, cools down water inside of cold water tank. © Cold water thermostat: Senses the temperature of cold water tank and controls the electric power supply to the compressor automatically in order to keep the constant temperature of cold water. © Over Load Protector (OLP): Protects the compressor and operates when rising up to abnormal temperature or energizing over current. © PTC Starter: Starts up the motor of compressor. © Drain cap: By opening this, you may drain out remaining water in hot water tank when cleaning or not using cooler for a long period of time. 3. LOCATION REQUIREMENTS A. This unit is intended to be installed underneath a conventional kitchen sink, in a cabinet not less than 36”" (914mm) wide (inside dimension). Chiller may be installed in any location in the cabinet base as long as there is a minimum of 5”" (127mm) between unit and cabinet walls. In order to have necessary air exchange for the unit, a free air opening of at least 60 square inches (387 cm2) should be provided in the kitchen counter. The opening should be located as close to the unit as possible and can be made in the ‘Dtoe space of the counter1 or ‘Dabove the toe space’ B. Make sure installation ground is flat and even. - Unbalanced placement may cause excessive noise and trembling of the cooler. C. Coolers are for indoor use only. Keep away from direct sunlight and excessive moisture. D. Avoid harmful gas or excessive heat. 4. INSTALLATION PROCEDURES A. Connect the 1/4”OD tubing between water inlet of chiller and the supply water hose with pressure rating suitable for use with the application. The tubing must be acceptable for use with potable water. B. Using the 1/4”OD tubing included with the (gooseneck) faucet, connect on water outlet of chiller. -Flush water in lines before installing gooseneck faucet. -Acceptable supply water pressure is 15~100 PSI (100~700kPa) CAUTION: TO PREVENT PROPERTY DAMAGE DUE TO WATER LEAKAGE, SEEK INSPECTION BY PLUMBERS TO SEE THE WATER PRESSURE IS LESS THAN 100PSI (690KPA) BEFORE YOU CONNECT THE SUPPLY WATER HOSE. C. Slowly open supply water valve. By opening faucet lever, let water flows for about one minute. Check all the connections. -Purge off all air from all water lines by opening faucet lever. Steady stream assures all air is ventilated. D. Prior to drinking, flush water through chiller for at least 5 minutes. E. Check the available power supply against the chiller data plate to assure correct electrical service. F. Plug in chiller and the chiller will be ready to serve you cold water in 30 minute after installation CAUTION: FAILURE TO ABIDE BY ABOVE PROCEDURE CAN CAUSE PHYSICAL DAMAGE ON THE COOLER. 5. STORAGE A. Unplug power cord. B. Open faucet until water is room temperature. C. Close the source water valve. D. Disconnect the water pipe from the product. E. Place a bucket beneath the drain pipe. Open the drain cover and cap. Then, drain the remaining water. F. When storing, ensure it stands on its erect position on the flat and even ground. (Do not lay the product on its sides down or upside down.) G. When not use for a long period of time, conduct product cleaning before you put in storage. CAUTION: FAILURE TO ABIDE BY ABOVE PROCEDURE MAY INCUR PHYSICAL DAMAGE ON THE COOLER. 7. TROUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSE REMEDY REFRIGERATION SYSTEM A. Compressor does not run. No electric power to outlet. The therm...
|