Resumen del manual


Turn heater off when using furniture box or on adjacent walls or furniture ish, wax, carpet cleaners, etc. turn into polish, wax, carpet cleaners, or similar white powder residue products Moisture/condensation noticed on windows 1. Not enough combustion/ventilation air 1. Refer to Air for Combustion and Ventilation requirements (page 4) 18 105071 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Heater produces a clicking/ticking noise 1. Metal expanding while heating or con1. This is common with most heaters. If just after burners are lit or shut off tracting while cooling noise is excessive, contact qualified service person Heater produces unwanted odors 1. Heater burning vapors from paint, hair 1. Open window to ventilate room. Stop us- spray, glues, cleaners, chemicals, new ing odor causing products while heater carpet, etc. (See IMPORTANT state-is running ment above) 2. Low fuel supply 2. Refill supply tank 3. Gas leak. See Warning statement 3. Locate and correct all leaks (see Check- at top of page ing Gas Connections, page 12) Heater shuts off in use (ODS operates) 1. Not enough fresh air is available 1. Open window and/or door for ventilation 2. Low line pressure 2. Contact local propane/LP gas company 3. ODS/pilot is partially clogged 3. Clean ODS/pilot (see Cleaning and Maintenance, page 16) Gas odor even when control knob is in OFF 1. Gas leak. See Warning statement 1. Locate and correct all leaks (see Check- position at top of page ing Gas Connections, page 12) 2. Control valve defective 2. Replace control valve Gas odor during combustion 1. Foreign matter between control valve 1. Take apart gas tubing and remove for- and burner eign matter 2. Gas leak. See Warning statement 2. Locate and correct all leaks (see Check- at top of page ing Gas Connections, page 12) 105071 19 FIREPLACE MANUFACTURERS INC UNVENTED PROPANE/LP GAS LOG HEATER ILLUSTRATED PARTS BREAKDOWN VFP18MV VFP24MV VFP30MV 11 17 19 18 25 24 20 20 26 27 286 7 27 27 24 9 8 10 12 14 21 22 26-1 26-2 23 6-1 6-2 13 15 16 4 5 3 2 1R 1L 20 105071 OWNER’S MANUAL This list contains replaceable parts used in your heater. When ordering parts, follow the PARTS LIST instructions listed under Replacement Parts on page 22 of this manual. VFP18MV VFP24MV VFP30MV KEY NO. PART NUMBER FOR DESCRIPTION QTY.VFP18MV VFP24MV VFP30MV 1L 105241-01 105241-02 105998-01 Left Front Log (#1L) 1 1R _____ 105241-03 105999-01 Right Front Log (#1R) 1 2 105243-01 105243-02 106000-01 Bottom Middle Log (#2) 1 3 105245-01 105245-02 106001-01 Rear Log (#3) 1 4 105249-01 105249-02 106002-01 Top Middle Log (#4) 1 5 105247-01 105247-02 106003-01 Crossover Log (#5) 1 6 101330-01 101330-05 101330-06 Front Burner Assembly 1 6-1 101008-01 101008-01 101008-01 Crossover Burner Gasket 1 6-2 101007-01 101007-01 101007-01 Crossover Burner 1 7 100999-01 100999-02 100999-03 Rear Burner Assembly 1 8 101331-10 101331-08 101331-09 Base Assembly (Includes Decals) 1 9 098271-07 098271-06 098271-06 Ignitor Cable 1 10 102445-01 102445-01 102445-01 Piezo Ignitor 1 11 098867-10 098867-10 098867-10 Gas Regulator 1 12 M11084-38 M11084-38 M11084-38 Screw 2 13 101011-01 101011-02 101011-03 Inlet Tube 1 14 098354-01 098354-01 098354-01 Control Knob 1 15 098462-03 098462-03 098462-03 Control Rod 1 16 098325-01 098325-01 098325-01 Roll Pin 1 17 098508-01 098508-01 098508-01 Valve Retainer Nut 1 18 102568-02 102568-02 102568-02 Gas Valve 1 19 101005-01 101005-01 101005-01 Valve Bracket 1 20 M11084-26 M11084-26 M11084-26 Screw 4 21 101004-10 101004-01 101004-02 Rear Burner Injector 1 22 101004-10 101004-02 101004-06 Front Burner Injector 23 102258-01 102258-01 102258-01 Burner Tube 1 24 099387-08 099387-08 099387-08 Pilot Tube 1 25 098276-01 098276-01 098276-01 1/8” Plug 1 26 099059-02 099059-02 099059-02 O.D.S. Pilot 1 26-1 098594-01 098594-01 098594-01 Ignitor Electrode 1 26-2 098593-01 098593-01 098593-01 Thermocouple 1 27 098249-01 098249-01 098249-01 Nut 4 28 101006-01 101006-01 101006-01 Pilot Bracket 1 PARTS AVAILABLE — NOT SHOWN 100563-01 100563-01 100563-01 Warning Plate 1 101055-02 101055-02 101055-02 Lighting Instructions Plate 1 100565-01 100565-01 100565-01 Warning Plate Fastener 1 100639-01 100639-01 100639-01 Caution Decal 1 101137-01 101137-01 101137-01 Hardware Kit 1 GA6060 GA6060 GA6060 Lava Rock 1 105071 21 FIR...

Otros modelos de este manual:
Los calentadores de gas - VFP24MV (464.77 kb)
Los calentadores de gas - VFP30MV (464.77 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría