Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Lifescan, modelo SureStep Blood Glucose Monitor

Fabricar: Lifescan
Tamaño del archivo: 2.27 mb
Nombre del archivo: 6c332d6e-1490-413f-9efa-2af272183374.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


It should not be used for the diagnosis of diabetes. ©2002, 1997 LifeScan, Inc. All rights reserved. The system described herein is covered by one or more of the following US patents: D371,198, D367,109, 5,418,142, 5,515,170, 5,526,120, 5,563,031, 5,605,837, 5,780,304, 5,789,255, 5,922,530, 5,968,836, and 6,335,203. Use of the system described herein is protected under US patent 4,935,346. Purchase of the system described herein does not act to grant a license under these patents. Such a license is granted only when the device is used with SureStepPro or OneTouch SureStep Test Strips. No test strip supplier other than LifeScan is authorized to grant such a license, and LifeScan does not endorse or encourage the use of any strips manufactured by anyone other than LifeScan. Table of Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . .v About this Guide . . . . . . . . . . . . . . . . . . . . . . . . .vi Here’s What You’ll Find in this Guide . . . . . . .vi Conventions Used in this Guide . . . . . . . . . . .vii Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii Chapter 1: Introduction . . . . . . . . . . . . . . . .1 Learning the SureStep Meter . . . . . . . . . . . . . . . . 2 Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . 4 SureStepPro Test Strips . . . . . . . . . . . . . . . . . . .10 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Infection Control . . . . . . . . . . . . . . . . . . . . . .16 Chapter 2: Operation . . . . . . . . . . . . . . . . .17 Coding the Meter . . . . . . . . . . . . . . . . . . . . . . . . 17 Quality Control Test . . . . . . . . . . . . . . . . . . . . .20 Glucose Control Solution . . . . . . . . . . . . . . . .21 Performing a Quality Control Test . . . . . . . . . 23 Control Solution Results . . . . . . . . . . . . . . . . 28 Linearity Test . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Patient Blood Test. . . . . . . . . . . . . . . . . . . . . . . 30 Performing a Patient Blood Test . . . . . . . . . . 31 Patient Results . . . . . . . . . . . . . . . . . . . . . . . 38 Chapter 3: Settings and Memory . . . . . . . .39 Meter Settings . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Meter Memory . . . . . . . . . . . . . . . . . . . . . . . . . 44 Using the Meter for the First Time . . . . . . . . 44 Recalling All Results in Meter Memory . . . . . 45 Recalling Most Recent Result After Testing . 47 Chapter 4: Cleaning and Maintenance . . .49 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Whento Clean the Meter . . . . . . . . . . . . . . . . 50 Cleaning the Outside of the Meter . . . . . . . . . 51 Cleaning the Test Strip Holder and Lens Area 51 Replacing the Batteries . . . . . . . . . . . . . . . . . . . 57 Chapter 5: Troubleshooting . . . . . . . . . . .61 Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . 63 Helpful Messages . . . . . . . . . . . . . . . . . . . . . . . 71 Meter Specifications . . . . . . . . . . . . . . . . .73 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 Preface The SureStep Meter is a simple, easy-to-use meter for monitoring blood glucose levels. The SureStep Hospital Blood Glucose Monitoring System offers diabetes caregivers and patients off-meter blood dosing of the test strip. The design can help reduce the risk of transmission of blood- borne pathogens between patients, while providing accurate and reliable blood glucose results at the point of care. About this Guide The SureStep Hospital Meter Operator’s Guide provides detailed instructions on using and maintaining the SureStep Meter. Although operating the meter is straightforward, it is important that you read the information presented in this manual, as well as the SureStepPro Test Strip package insert. Here’s What You’ll Find in this Guide Chapter 1, Introduction, provides you with an overview of the meter, its display symbols, as well as general information about SureStepPro Test Strips. Chapter 2, Operation, includes instructions for coding the meter and performing a quality control test and a patient test. Chapter 3, Settings and Memory, provides information on the various meter settings and how you can change them. Also included in this chapter is information on meter memory. Chapter 4, Care and Maintenance, instructs you on how to clean the meter and change the batteries. Chapter 5, Troubleshooting, lists the error codes that may appear during operation and offers possible solutions to correct a problem. Conventions Used in this Guide ¦ NOTE Points out additional information that may be helpful. . IMPORTANT Contains information necessary to successfully perform the test. ^ CAUTION Alerts you to situations that could result in instrument damage, failure in a procedure, or possible inaccurate results. Help 1 Read through the section of the guide specific to the operation you are performing. Refer to the table of contents or index to locate in...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría