Electrical System: Wired for single phase, 115V AC with 6’ cord and 3-prong plug supplied with each deck. Gas Control System: Includes pressure regulator, flame switch safety, pilot filter, pilot adjustment Oven Heating: Aluminized steel bar burner. Dual flow fan recirculates heat directly from combustion area and within oven cavity. Controls: Oven thermostat temperature type adjustable for 250° - 500° F with a low setting. 536 Rev 2 (June/2009) Printed in USA . 536D . 536A . 536R Dimensions -in (mm) Models Exterior Cook Top Door Opening Oven Bottom 3/4” Gas Conn. Electric Width A Depth B C D E F G H J K L M N O P Q R 536D, 536R 36.50” (927) 36.50” (927) 29.75” (756) 32.50” (826) 11.75” (298) 2.75” (70) 59.50” (1511) 22.50” (572) 31.00” (787) 6.00” (152) 37.00” (940) 15.50” (394) 13.00” (330) 3.25” (83) 30.25” (768) - - 536A 36.50” (927) 46.50” (1181) 29.75” (756) 32.50” (826) 11.75” (298) 2.75” (70) 59.50” (1511) 22.50” (572) 31.00” (787) 6.00” (152) 37.00” (940) 15.50” (394) 13.00” (330) 3.25” (83) 30.25” (768) 24.00” (610) 6.00” (152) Models Burners (BTU Each NAT/LP) Oven Interior Crate Size Cubic Volume Crated Weight Griddle Open Oven Width Depth Height Width Depth Height 536D - 6@(27K/24K) 1@(45K/40K) 26.00” (660) 26.50” (673) 14.00” (356) 44.00” (1118) 45.50” (1158) 48.00” (1219) 55.6 cu. ft. 1.57 cu.m.. 535 lbs. 242.7 kg. 536A - 6@(27K/24K) 1@(32K/30K) 26.00” (660) 24.00” (610) 14.00” (356) 536R - 6@(27K/24K) 1@(45K/40K) w/ 9,500 BTU Broiler 26.00” (660) 26.50” (673) 14.00” (356) UTILITY INFORMATION MISCELLANEOUS GAS: - 536D Total BTU-NAT: 207,000; LP: 184,000 - 536A Total BTU-NAT: 194,000; LP: 174,000 - 536R Total BTU-NAT: 216,500; LP: 183,500 - Pressure regulator is supplied with unit - Required supply line size to the regulator is 3/4” NPT. - Required minimum inlet pressure - Natural gas 5” W.C. - Propane gas 10” W.C. ELECTRICAL: - AAA battery required for electronic ignition system (536 Only) - Standard -115/60/1 furnished with 6’ cord with 3-prong plug. Total max amps 3.8. - Optional -208/60/1, 50/60/1 or 3 phase. Supply must be wired to junction box with terminal block located at rear. Total max amps 2.6. - If using Flex-Hose, the I.D. should not be smaller than 3/4” and must comply with ANSI Z 21.69 - If casters are used with flex hose, a restraining device should be used to eliminate undue strain on the flex hose - For installation on combustible floors (with 6” high legs) and adjacent to combustible walls, allow 6” clearance. - Recommended - Install under vented hood - Check local codes for fire, installation and sanitary regulations. - If the unit is connected directly to the outside flue, an A.G.A approved down draft diverter must be installed at the flue outlet of the oven. NOTICE: Southbend has a policy of continuous product research and improvement. We reserve the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions...
Otros modelos de este manual:Hornos Eléctricos - 536A (375.14 kb)
Hornos Eléctricos - 536A (375.14 kb)
Hornos Eléctricos - 536D (375.14 kb)