Please keep the booklet handy. You may wish to refer to it at a later date. CDA The marking confirms that the appliance conforms to the following EU directives: -safety requirements of EEC Directive “Gas” 90/396; -safety requirements of EEC Directive “Low voltage” 2006/95/EC; -protection requirements of EEC Directive “EMC” 89/336; -requirements of EEC Directive 93/68. INSTALLATION The oven must be installed in accordance with the installation instructions contained in this booklet. Connection to the electricity supply must be made by a competent electrician. Warning this appliance must be earthed. BEFORE USE Please ensure that all packing has been removed from the appliance before switching on. 2 Electrical supply to your oven Electrical supply to your oven IMPORTANT: Installation must be carried out according to the manufacturer's instructions. Incorrect installation may cause harm and damage to people, ani- mals or property, for which the manufacturer accepts no responsibility. Before carrying out any work on the electrical section of the appliance, it must be disconnected from the mains. Connection to a good earth wiring system is absolutely essential. The manufacturer accepts no responsibility for any inconvenience caused by failure to comply with this rule. DETAILS . Connection to the electric power supply must be carried out by a qualified technician and following the appropriate safety regulations. . Before carrying out the connection to the power supply, the voltage rating of the appliance (stamped on the appliance identification plate) must be checked for correspondence to the available mains supply voltage, and the mains electric wiring should be capable of handling the appliance’s power rating (also indicated on the identification plate). Figure 1 Green & Yellow Earth Blue Neutral 3 amp fuse Brown Live 3 . CONNECTION BY A THREE PIN SOCKET (Fig. 1) . The appliance must be connected to a 220-240 volts 50 cycle AC supply by means of a three pin socket, suitably earthed and should be protected by a 3 amp fuse. . If the mains plug is unsuitable for the socket outlet in your home or is removed for any other reason, then the cut off plug should be disposed of safely to prevent the hazard of electric shock. . There is a danger of electric shock if the cut off plug is inserted into any 13 amp socket outlet. . CONNECTION USING FIXED WIRING (Fig. 2) . It is possible to connect the appliance directly to the mains supply by means of a heavy duty switch with 3 mm minimum distance between the contacts. . A double pole switch must be provided no further than 2 metres from the appliance to the electrical supply. All supply current and earth conductors must be able to withstand an ambient temperature of 75°C. . The appliance must be protected by a 3 amp fuse. Figure 2 DOUBLE POLE SWITCHED FUSED SPUR OUTLET FUSE ON 4 GENERAL NOTES . The wires in the mains lead on this appliance are coloured in accordance with the following code: Green and Yellow - Earth Blue – Neutral Brown – Live . As the colours may not correspond with the markings identifying the terminals in your plug or in your spur box, proceed as follows: . The green and yellow wire must be connected to the terminal which is marked with the letter E or with the earth symbol or coloured green and yellow. . The blue wire must be connected to the terminal marked N or coloured black. . The brown wire must be connected to the terminal marked L or coloured red. . The power supply cord must not touch against any hot surfaces and must be placed so that its temperature does not exceed 75°C at any point along its length. . After having installed the appliance, the power switch or power plug must always be in a accessible position. . The appliance must have its own supply; any other appliances installed near it must be supplied separately. . N.B. For connections to the mains power supply, never use adaptors, reductions or multiple power points as these may overheat and catch fire. . In the event that installation should require modifications to the mains supply wiring system or if the power plug is not suitable for the type of power point available, it is recommended that a qualified technician be called to carry out substitution. The technician will also have to verify that the cross-section of the electric cables on the power point match the appliance’s power rating. . If the supply cord is damaged, it must be replaced by a special cord by a qualified electrical technician in order to avoid a hazard. Figure 3 FEEDER SPECIAL CABLE SECTION Type “HO5RR-F” 230 VAC 50Hz 3 x 0,75mm2 . The supply cable must be replaced with a cable of the same type. . The electrical cable must be connected to the terminal board following the diagrams of Fig. 3. 230 V L1 N(L2) PE 5 Gas supply requirements Gas supply requirements .............................. .........................................................................................................................................