Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario CDA, modelo DC730

Fabricar: CDA
Tamaño del archivo: 1.67 mb
Nombre del archivo: 7c8d21d9-6a54-458f-a16c-a0b8bd5f28a9.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


35, 36) • Installation "C" by Using Housing Unit (figs. 37, 38, 39) CAUTION: Do not lift the double oven by the door handles. WARNING ! – We would point out that the adhesive which bonds the plastic laminate to the furniture must withstand temperatures not less than 150° C to avoid delamination. – The appliance must be housed in heat resistant units. – The walls of the units must be capable of resisting temperatures of 75° C above room temperature. 544 20 538 718 595 42 560 B 720 min ( * ) B 570 min Fig. 33 (*) M easure 560 mm Gap 544 20 538 718 595 42 560 B 720 min ( * ) B 570 min Fig. 33 (*) M easure 560 mm Gap 26 Installation "A" between Existing Side Cabinets (560 or 600 mm GAP) (figs. 32, 33, 34, 36) – Mount the 2 (two) metal supports “B” (supplied with the appliance in a separate kit) as indicated in Figs. 33 or 36). – Fig. 36 only -prepare 2 wood uprights “A” (width 20-50 mm, thickness 18 mm, length 650 mm); mount the 2 wood uprights “A” to the cabinet walls as indicated in figure. – Build in the double oven making it slide on the metal supports “B”. Installation "B" between Side Cabinets by Removing Provious Housing (figs. 35, 36) – Remove previous housing. – Mount the 2 (two) metal supports “B” (supplied with the appliance in a separate kit) as indicated in Fig. 36. – Prepare 2 wood uprights “A” (width 20-50 mm, thickness 18 mm, length 650 mm); mount the 2 wood uprights “A” to the cabinet walls as indicated in figure. – Build in the double oven making it slide on the metal supports “B”. Fig. 32 WARNING ! VERY IMPORTANT The underside of the cabinet shall be opened to allow correct air circulation. Support base calculated from the underneath of the worktop to the top support base of the “B” supports. 560 mm Gap Installation “A Installation “A Fig. 34 600 mm Gap 27 544 20 538 7 1 8 595 600 WARNING ! VERY IMPORTANT The underside of the cabinet shall be opened to allow correct air circulation. 7 20 min ( * ) B 570 min 20 22 1 5 20 - 50 18 A B 650 A Support base (*) Measure calculated from the underneath of the worktop to the top support base of the “B” supports. Fig. 36 Installation “B” Pre existing 600 mm cabinetry Fig. 35 600 mm Gap 28 28 Installation "C" By Using Housing Unit (figs. 37, 38, 39) • Remove the single oven shelf, if fitted, as indicated in figure 37. • Remove the upper cross member support as indicated in figure 38. • Cut the bottom of the housing as indicated in figure 38. • Screw oven base housing to adjoining cabinetry by suitable screws (not supplied) as indicated in figure 39. • Check the position of the cabinet legs to ensure the cut-out does not interfere with the legs support. Otherwise the cabinet may have to be removed as in INSTALLATION TYPE "B". • Mount the 2 (two) metal supports “B” (supplied with the appliance in a separate kit) as indicated in Figs. 39). • Build in the double oven making it slide on the metal supports “B”. 29 29 Fig. 8.3b Remove single oven shelf, if fitted. Cabinet for installing the oven Fig. 37 54420538718595BFig. 39 40 30 600 B 720 min 42 B Support base 40 Measure calculated from the underneath of the worktop to the top support base of the “B” supports. Fig. 38 1515302518183630Installation “C” 30 30 Fixing the Double Oven door and the oven frame. IMPORTANT: space as allow air circulation. STAND AWAY The double oven should then be secured by 6 screws (not supplied) fitted into the holes provided at the sides of the oven (Fig. 40). If you open the oven doors, you will see some screw holes. Remember the housing should not be free standing but be secured to the wall and/or adjacent fittings. Note: It is essential that when installing your double oven, adequate air circulation is available within the installation. Inadequate air circulation may greatly impair the performance of your double oven and may affect adjacent cabinets due to an increase in temperature. Adjust the hinges of furniture door adjacent to the double oven to allow a 5 - 7 mm gap between the furniture If installing a base panel leave a indicated in fig. 41 to 20010Fig. 41 10 mm 2 mm Fig. 42 Fig. 40 KEEP ATTENTION ! FROM LOUVERS POSITIONED BELOW THE CONTROL PANEL. HOT AIR WHICH ESCAPES CAN CAUSE BURNS TO HANDS, FACE, END/OR EYES. KEEP CHILDREN AWAY. 31 31 IMPORTANT: – To avoid damage to the lower trim please note the following instructions. – The lower trim is designed to allow for good air circulation and the correct opening of the oven door. – To ensure the trim is not damaged due to the appliance being placed on the floor, the appliance should be suitably supported as in below illustrations. – After installation the appliance door should be slowly opened to ensure no damage has occurred. – No responsibility for lower trim damage will be accepted if these instructions have not been followed. OVEN DOOR LOWER TRIM AIR FLOW Fig. 43 Air Flow Oven Door Lower Trim 32 32 Electrical Installation For your safety please read the following information: WARNING! Before effecting any intervention on t...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría