|
Resumen del manual
The surface must be level. Protect generator from heavy dust, sand, dirt, rain, or snow. Do not locate generator near standing water and snow. Make sure area is well-vented. Only responsible adults should use generator. Never let anyone operate generator without proper instructions. NOTE: If oil level is too low, oil alert system will keep engine from starting (See “Oil Alert System,” page 5). Make sure oil level is full before starting. See “Engine Oil,” page 10. Before starting the engine, disconnect all electric loads from generator. STARTING IMPORTANT: The engine speed is preset. The throttle is locked in preset position. Do not adjust throttle. Preset position lets engine run at 3600 RPM under load. The engine must maintain 3600 RPM for generator to create correct voltage. Running engine at lower speeds will damage generator and powered items. IMPORTANT: Never start generator with electrical loads connected. Start engine before adding electrical loads. 1. Make sure gasoline tank is full. See “Fuel,” page 10 for fuel information. 2. Move fuel valve lever to the ON position (See Figure 24). 3. Move choke lever fully to the left (See Figure 24) or pull choke button out (Model 3WY47 only, See Figure 25). This closes the choke. NOTE: You may not need to close choke if engine is warm or air temperature is high. 4. Start the engine. Choke Lever (Closed Position) Fuel Valve Lever (ON Position) Figure 24 – Fuel Valve Lever On, Choke Lever Closed (Models 3W736C, 3WY44, 3WY46, 3TE27A, and 3WY45) Choke Button (ClosedPosition) Figure 25 – Choke Button Closed (Model 3WY47 Only) RECOIL STARTER (NOT AVAILABLE ON MODEL 3WY47) Turn engine switch to the ON position (See Figures 26 and 27). Remove slack from starter rope by lightly pulling starter grip. Next, pull starter rope briskly. IMPORTANT: Do not let starter grip snap back against engine. Return it gently. This will prevent damage to starter. NOTE: If engine does not start, check the oil level in the cranckcase. Add oil as needed. Be sure engine is on a level surface. See “Oil Alert System,” page 5. Engine Switch Figure 26 – Engine Switch in ON Position (All Models Except 3WY46, 3WY45, and 3WY47) ELECTRIC STARTER (MODELS 3WY46, 3WY45, AND 3WY47 ONLY) Turn the engine switch to the START position (See Figure 27). Hold it there until engine starts. When engine starts, let switch return to the ON position. IMPORTANT: Do not use electric starter more than five seconds. Starter motor damage may occur. If engine fails to start, release the switch and wait ten seconds. After ten seconds, try starting again. NOTE: If engine does not start, check the oil level in the cranckcase. Add oil as needed. Be sure engine is on a level surface. See “Oil Alert System,” page 5. Engine Switch OFF ON START ENGINE SW CIRCUIT BREAKER ON/push OFF Figure 27 – Engine Switch (Models 3WY46, 3WY45, and 3WY47 Only) 14 Dayton Operating Instructions and Parts Manual 15 Version B - For Reduction G016.J ® Models 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Figure 29– Choke Lever Opened (Model 3WY47 Only) Choke Button (Open Position) 5. As engine warms up, slowly move choke lever fully to the right (See Figure 28). This opens the choke. On Model 3WY47, the choke will automatically open (See Figure 29). Figure 28 – Choke Lever Opened Choke Lever (Open Position) Operation (Continued) AUTO-IDLE OPERATION IMPORTANT: Never start engine with electrical loads connected. Start engine before adding electrical loads. 1. If engine is cold, turn the auto-idle switch OFF. 2. Start engine. Allow engine to warm up with no load for five minutes. 3. Turn auto-idle switch ON. Engine will slow to idle speed. Engine idle speed is preset. Idle speed adjustment should not be necessary. 4. Operate generator according to specifications outlined in owner's manual. 5. Engine will automatically increase to normal operating speed when you plug load into any generator outlet. NOTE: The 250 Volt/50 Amp receptacle is not connected through the auto-idle circuit. The auto-idle switch must be turned off to get full power out of this receptacle (See Figure 30). 6. The auto-idle system should be turned OFF when generator is shut down. ADJUSTING THE IDLE SPEED IMPORTANT: Adjust the idle speed only: • If the idle speed becomes too high. • If the engine idle speed will not regulate (engine idles and speeds up again and again). 1. Turn auto-idle switch OFF. Start engine. Allow engine to warm up with no load for five minutes. 2. Remove engine linkage cover (Models 3WY46 and 3WY45 only). 3. Push plunger into solenoid body to manually engage solenoid and set idle speed. 4. Loosen the M8 nut that holds the solenoid mounting bracket to the generator (Models 3WY46 and 3WY45 only, See Figure 31). Do not loosen bolt that holds the solenoid mounting bracket to the generator on Model 3WY47, See Figure 32). Figure 30 - Auto-Idle Switch Location on Control Panel RESET TEST 120 VOLTS RESET 240 VOLTS RESET RESET RESET ENM 00000005 HOURS 1/10 120...
Otros modelos de este manual:Electricidad - 3WY46 (1.36 mb)