Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Briggs & Stratton, modelo AK7

Fabricar: Briggs & Stratton
Tamaño del archivo: 202.82 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The TIME and TEMP set points are remem3. The generator should produce steam in 5 to 10 ON/OFF button. bered by the K60 for your next bath unless power minutes and will turn off automatically in 60 to the steam generator is lost. minutes or less depending on the set time. The 5. To change the preset temperature setting control will alternately display time remaining press and hold the TEMP button on the control. and the actual temperature at the sensor in your While continuing to hold the button, the tempera- steam room every 5 seconds. ture display will increase in 1 degree increments SECTION 3: TAKING A STEAMBATH 1. Wait for the steam room to reach a comfortable temperature. 2. Remove clothing and jewelry. 3. Enter the steam room and close the door to prevent steam from escaping. 4. Relax and enjoy the warm steam releasing tense muscles and refreshing the entire body. 5. If your steam room has a shower a pleasant experience can be achieved by taking a warm shower with the steam. 6. After a steambath a warm shower will give you a feeling of relaxation and is conducive to a good night’s rest. A cold shower will refresh you and is a good way to start a busy day or prepare you for an evening out. SECTION 4: MAINTENANCE OF YOUR AK STEAM GENERATOR The steam generator, steam head, fittings and plumbing connections should be inspected regularly for water leaks and damage. The AK steam generator is equipped with a manual drain valve for flushing sediments from the generator tank. This procedure should be scheduled monthly or more often depending on local water conditions and steam bath usage. Flushing Procedures: 4. The unit will drain without heating the water. 1. The generator should be cool. 5. Allow the water to run for a full 10 minutes. 2. Press the control ON. 6. Push the control OFF. When the water stops flowing out the drain, close the manual drain 3. Open the manual drain valve. valve. 4209-24 12-09-02 AK Series w/K60 Control Owners Manual page 3 SECTION 5: TROUBLE SHOOTING GUIDE The troubleshooting guide is meant as a general aid only. There are no user serviceable parts in the generator. All repairs should be performed by a qualified service person. For additional assistance or the factory authorized service person nearest you call: AMEREC's Service Department at 1-800-331-0349. SYMPTOMS PROBABLE CAUSES ACTION TO BE TAKEN Control won't turn "ON". (Control light off). Improper power supplied (no power). or Control improperly connected. or Control cable is faulty. or Contol is faulty. 1. a. Make sure circuit breaker is "ON". b. Using a voltmeter, check the voltage across the two fuses on the "PCA" printed circuit assembly. Voltage should be 208V / 240V. c. Check fuses, if the fuse(s) are blown, replace with Buss# MDL 15/100 or equivalent fuse. If the fuse blows again -call AMEREC's Service Department. 2. Check control(s) instal ll ed per Section 6-5 in the AK INSTALLATION AND SERVICE INSTRUCTIONS. 3. Replace control cable -call AMEREC's Service...

Otros modelos de este manual:
Electricidad - AK10 (202.82 kb)
Electricidad - AK10 (202.82 kb)
Electricidad - AK5 (202.82 kb)
Electricidad - AK10 (202.82 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría