This will cause the thermocouple or thermopile to cool. When the thermocouple cools, the heater will shut down. Correct Pilot Flame Pattern Figure 12 Incorrect Pilot Flame Pattern Figure 13 If pilot flame pattern is incorrect, as shown in Figure 13 • See Troubleshooting, page 15. Cleaning and Maintenance/Pilot Oxygen Depletion Sensor Pilot (Figure 14) When the pilot has a large yellow tip flame, clean the Oxygen Depletion Sensor as follows: 1. Clean the ODS pilot by loosening nut B from the pilot tubing. When this procedure is required, grasp nut A with an open wrench. 2. Blow air pressure through the holes indicated by the arrows. This will blow out foreign materials such as dust, lint and spider webs. Tighten nut B also by grasping nut A. Figure 14 R-3451 Page 11 Main Burner Flame Pattern (Figure 15 and Figure 16) Figure 15 shows a correct main burner flame pattern. Figure 16 shows an incorrect main burner flame pattern. Correct Main Burner Flame Figure 15 Incorrect Main Burner Flame Figure 16 If main burner flame pattern is incorrect, as shown in Figure 16 • See Troubleshooting, page 15. Cleaning and Maintenance / Main Burner Warning: Turn off heater and let cool before cleaning After use, cleaning of the main burner may be required for the proper flame. The main burner may be cleaned by applying air pressure to the ports on the main burner. Cleaning the Log Set and Firebox During the annual inspection and maintenance appointment, the service person should clean dust, lint, and any light accumulation from the logs and the firebox area. An extra-soft brush should be used on the logs as they are extremely fragile; a vacuum cleaner may be used on the firebox. If at any time the logs cannot be removed or installed without forcing, the cause must be found. The logs must never be forced. CAUTION: The ceramic logs are durable when handled and installed properly. However, they are delicate and may be damaged easily if not handled with care. Handling damage to the ceramic logs is not covered by warranty. DO NOT HANDLE LOGS WHILE THEY ARE HOT. ALLOW PLENTY OF TIME FOR THE APPLIANCE TO COOL COMPLETELY BEFORE HANDLING. OPERATING INSTRUCTIONS CIVF-25 ON/OFF/REMOTE Switch CIVF-25 is equipped with an ON/OFF/REMOTE switch which is located on the wiring chase. A wire harness is attached to the ON/OFF/ REMOTE switch. The red, black and green (wires) female push-ons attach to the ON/OFF/REMOTE switch. At the opposite end of the wire harness, the black and green (wires) female push-ons attach to the gas valve. An additional green wire and the red wire, which are stripped and bare, will attach to the 750 millivolt wall thermostat accessory, or, to one of the other accessories that can be purchased for use with your log set. Operation of ON/OFF/REMOTE Switch with no Accessories To ignite main burner, turn the control knob on the gas valve from the PILOT position to the ON position. Turn the ON/OFF/REMOTE switch from the OFF position to the ON position. The additional green wire and red wire, which are stripped and bare are not used. Operation of ON/OFF/REMOTE Switch with Accessories 750 Millivolt Wall Thermostat, GWSG-T Connect the green and red, stripped and bare, wires on the ON/OFF/ REMOTE switch wire harness to the wall thermostat. Turn the ON/OFF/ REMOTE switch on the wiring chase to the REMOTE position. Set the wall thermostat to the desired temperature. It is important to use wire of a gauge proper for the length of the wire: RECOMMENDED WIRE GAUGES Maximum Wire Length Gauge 1' to 10' 18 10' to 25' 16 25' to 35' 14 Wall Switch, FWS-1 Connect the green and red, stripped and bare, wires on the ON/OFF/ REMOTE switch wire harness to the wall switch. Turn the ON/OFF/ REMOTE switch on the wiring chase to the REMOTE position. Pivot the rocker switch on the FWS-1 to the ON position. Battery Operated Remote Control, FRBC-1 and FRBTC-1 Connect the green and red, stripped and bare, wires on the ON/OFF/ REMOTE switch wire harness to the remote receiver that is a component in the FRBC-1 and FRBTC-1. Turn the ON/OFF/REMOTE switch on the wiring chase to the REMOTE position. Follow instructions in the FRBC-1 and FRBTC-1 to complete installation. Note: If batteries fail in FRBC-1 or FRBTC-1, and immediate heat is desired, turn the ON/OFF/REMOTE switch on wiring chase from the REMOTE position to the ON position. Electric (120 volt) Operated Remote Control, FREC-1 Connect the green and red, stripped and bare, wires on the ON/OFF/ REMOTE switch wire harness to the wires on remote receiver that is a component in the FREC-1. Turn the ON/OFF/REMOTE switch on the wiring chase to the REMOTE position. Follow instructions in the FREC-1 to complete installation. Note: If electric (120 volt) fails in FREC-1, and immediate heat is desired, turn the ON/OFF/REMOTE switch on wiring chase from the REMOTE position to the ON position. Page 12 R-3451 Wiring of ON/OFF/REMOTE Switch with 750 Millivolt Wall Thermostat Accessory and Another Accessory Connect ...

Otros modelos de este manual:
Eléctrico - CIVF-25-2 (1006.45 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría