Iniciar sesión:
Votos - 4, Puntuación media: 3.3 ( )

Manual de usuario Sunbeam, modelo HE4900

Fabricar: Sunbeam
Tamaño del archivo: 209.12 kb
Nombre del archivo: 0cb6263a-27e2-4598-b53b-b0de99205e86.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Wall mounting your heater Before using your Euro Plus heater ensure it is securely mounted on a wall. Wall mounting For maximum efficiency this heater should be positioned so that the heat generated mixes with the maximum volume of air. It can be installed in any room of the home, including the bathroom, in accordance with the instructions below. 1. Remove the wall mounting bracket from the rear of the heater by squeezing the clips (at A and B in figure 2 below) and pulling towards you. A B Figure 2 2. Select a suitable location to mount the heater, ensuring that it is at least 10cm below any curtains or window furnishings, 10cm from any furniture located to either side, and 75cm from any furniture placed in front of the heater, as shown in figure 3. The heater must be mounted horizontally, with the control panel at the top. A = 10 cm A B = 10 cm C = 75 cm Figure 3 Note: any electrical appliances to be fitted in a bathroom should be installed by a qualified electrician in accordance with Australian/New Zealand Standard Wiring Rules. Portable heaters should not be used in a bathroom. Heaters that can be permanently fixed must be installed so that any controls cannot be reached by a person using a bath or shower, as shown in figure 4. 60cm 60cm Figure 4 Wall mounting your heater (continued) 3. Mark the first top screw location on the wall, at least 630mm from the floor or skirting board. The base of the heater must be at least 200mm from the floor to ensure adequate air flow into the air inlet. Drill the first hole using a suitable drill bit. 4. Measure and mark the second drill hole, 564mm from the first hole. Drill the hole. 5. Measure and mark the bottom screw holes, 289mm below the top two holes. Drill. 6. Position the bracket over the drill holes and screw into position. 7. To place the heater on the bracket, insert the lower clips first then the top, and push firmly until it clicks into position, as shown in figure 5. Figure 5 Attaching the wheels Before attaching the wheels, remove the wall mounting bracket from the rear of the heater by pushing down on the top clips and pulling towards you. 1. Position the wheel assembly over the base of the heater, with the vertical bracket to the rear of the unit, as shown in Figure 6. 2. Align the screw hole in the vertical bracket (C) with the screw hole in the rear of the heater. Place the washer on the screw, insert the screw and fix loosely. Do not tighten. 3. Align the screw holes on the underside of the wheel assembly (A and B) with the holes on the base of the heater. Insert each screw and washer and tighten. Figure 6 A B C Once all screws are correctly positioned, tighten the screw in position C. 4. Repeat on the other side. Using your heater 1. Install the heater in accordance with the instructions above. 2. Insert the plug into a 230-240V power outlet and turn the power on. 3. Ensure that the air inlet vent on the underside of the heater and the air outlet are clear of obstructions. 4. Move the on/off switch to the on position (I). 5. Adjust the thermostat dial to your desired heat level, from 1 to 12. 6. Once the selected temperature is reached, the electromechanical thermostat will constantly monitor the room temperature and adjust the heat output to maintain it. 7. To switch the heater off, move the on/off switch to the off position (O). Restricting the temperature range With the aid of two pins at the back of the 2. Insert the pins in the desired position to unit, you can limit the range of the limit or fix the rotation of the thermostat thermostat dial. Use one pin to lock the dial as desired. thermostat at a fixed temperature, or two pins to fix a set temperature range. One pin determines the upper value, and the other determines the lower value. 1. To remove the pins from their original position, move each one back and forth using a pair of needle nose pliers to loosen them. Figure 7 Resetting the safety auto shut off The safety auto shut off detects any abnormally high temperatures within the heater and shuts it off to prevent overheating. Should the safety auto shut off activate and switch off the heater, it will need to be reset. 1.To reset the heater, move the on/off switch to the OFF position. 2.Unplug the heater and wait 5-10 minutes for the unit to cool down. 3.After 5-10 minutes, plug the heater in again and operate as usual. Care and cleaning Ensure that the heater is switched off and disconnected from the power outlet before cleaning. Carefully wipe the exterior of the heater with a soft damp cloth and dry thoroughly with a dry cloth. Over time dust may accumulate on the front vent of the heater, this can be removed by wiping with a damp cloth, or carefully going across the vent with a vacuum cleaner with brush attachment. Do not use harsh or abrasive cleaners to clean your heater, as these will damage the surface. is a registered trademark of Sunbeam Corporation Limited. Euro Plus is a trademark of Sunbeam Corporation Limited. Made in Fr...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría