Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Dimplex, modelo CAL200

Fabricar: Dimplex
Tamaño del archivo: 239.59 kb
Nombre del archivo: 545c9de8-f30a-4da1-a10e-f1dd1a6276c6.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


IMPORTANT - Do NOT connect the BLACK pilot wire to earth Care should be taken with the installation of the pilot wire(s) as when switching to background (set back) they become energised at 240V although only at a current of 1mA. 1. Place the legs under the heater In every case a suitable means of isolation must be provided for the pilot wire and marked to 2. Position the hinges into the grooves in the air inlet indicate that two sources of supply may be present at the heater. 3. Unscrew the jacks, until they reach the floor Where pilot wires are installed separately from the heater final sub-circuit they should be protected, double insulated and carry their own integral earth continuity conductor. Operation Mode Selection Dial (A) Use this rotary dial to select the function you require Symbol Function Description Frost Protection Heater will switch on to provide frost protection if the room drops below 5.C Background (set back) Heater will maintain a lower temperature level for background heating (comfort less 3.5.C) Comfort Heater will maintain the temperature set on the thermostat dial Off Heater will not function Programme Heater will be controlled by a programming device Off Note: If the programme function is selected but no programming device is being used, the heater will function in comfort mode The following Dimplex programmers are available: Pilot Wire Wall Mounted Controller (2 Zone) – Part no. RX010006 MBS Wall Mounted Programmer (2 Zone) – Part no. RX010007 MBS Slot in Receiving Cassette – Part No. RX9913 MBS Slot in Programming Cassette (Single Zone) – Part no. RX9912 Pilot Wire Programming Cassette (Single Zone) – Part no. RX9911 Function Display (B) Neon indicators adjacent to the function selector will light to show the mode selected Setting the Comfort Temperature (C) Use the thermostat dial (C) to select your desired room temperature. The markings on the dial are in approximately 3.5.C increments. The settings are (Frost Protection) and numbers 1-10 (MAX). The quickest way to find your comfort setting is to turn the thermostat dial to the maximum setting. When your ideal comfort level is achieved, turn the thermostat dial down until the thermostat switches off (the neon light will go out) Leave at this setting and the heater will automatically maintain the desired temperature. Thermostat Light (D) The neon indicator below the thermostat will light when the heater is operating. Background (set back) The background setting is preset at - 3.5.C this is the amount the room temperature will be allowed to drop when you switch the function selector from comfort to background. Reverting to comfort mode will automatically cause the temperature to rise to the setting on the thermostat dial. Advice on Using your Heater • For greatest economy switch the heater to background (setback) if you leave the room for long periods of time or before going to bed. • Do not set the comfort level too high. Even small reductions on the thermostat setting...

Otros modelos de este manual:
Eléctrico - CAL075 (239.59 kb)
Eléctrico - CAL100 (239.59 kb)
Eléctrico - CAL150 (239.59 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría