See Wiring Diagram (Fig. 12 or Fig. 13). Remove the cover from electrical junction box and connect power supply wires to wires designated, using wire nuts. The power cord supplied may be used for installation, if permitted by local codes and regulations. If the power cord supplied cannot be used, the power supply wiring must be 90 degrees centigrade in a metal cable and should be completed by a qualified installer complying with NFPA Standard No. 70 and local codes. g) Optional Plenum Fan Control Switch (Part No. 11PCS) is available for installation on the plenum of central hot air heating furnace. The purpose of this switch is to activate the circulating fan of the central hot air heating furnace when the temperature in the plenum exceeds 120 degrees F., and shut off the fan when the temperature in the plenum is reduced to 100 degrees F. This avoids overheating the plenum. The electrical supply for operation of this fan control switch is to be obtained from the same electrical supply as the central hot air heating system. (See Fig. 14) Follow the instructions of the wiring diagram (Fig. 5) Do not make connections across Limit Control in the furnace. Make electrical wire connections in accordance with NFPA Standard No. 70 and local codes in the power supply junction box (See Fig. 15). The wiring to complete the connections should be 18 AWG minimum copper and 90 degrees centigrade in a cable. 12 Repair Parts List Model 1303 KEY PART NO. DESCRIPTION QTY. 1 23466 Cabinet Left Side 1 2 23464 Cabinet Back Panel 1 3 88032 Flue Collar Gasket 1 4 40246 Flue Collar 1 5 22761 Flue Collar Ring 1 6 83086 Flue Collar Mounting Bolts 1/4-20x3/4" 4 83227 Flue Collar Mounting Bolts 1/4-20x1" 2 7 83250 Flue Collar Mounting Nuts 1/4-20 kep nut 1 8 23462 Cabinet Top Panel 1 9 23465 Cabinet Right Side 1 10 23467 Front Upper Panel 1 11 23469 Right Upper Panel 1 12 23468 Front Bottom Panel 1 13 23470 Front Left Panel 1 14 68546 Firebox Weldment 1 15 68607 Feed Door Assembly (40186) 1 16 68699 Ash Door Assembly (40289) 1 17 17350 Brick Retainer (2ea.) 2 18 17130 Rear Liner 1 19 89066 Firebrick 10 20 40076 Grate 1 21 67444 Ash Pan 1 22 22538 Air Intake Box 1 23 22539 Air Intake Door 1 24 68560 Air Intake Box Cover Weldment 1 25 89503 Thermostat Linkage 1 26 67743 Thermostat 1 27 89142 Thermostat Knob 1 28 23463 Cabinet Bottom 1 29 23303 Access Plate 1 30 89354 Door Handle (Feed Door) 1 31 89354 Door Handle (Ash Door) 1 32 88033 3/8" Rope Gasket 44" 33 88033 3/8" Rope Gasket 29" 35 68561 Base Assembly 1 36 88064 Air Box Cover Gasket 1 37 68587 Outlet Baffle Weldment 1 38 23193 Baffle Bracket 1 39 22247 Front Firebox Liner 1 40 66080 Grate Liner Support 2 41 22090 Smoke Curtain 1 42 22171 Smoke Curtain Bracket 2 * 83086 Screw/ 1/4-20x3/4 MS,SL,FL 3 * 83250 1/4-20 Kep Nut 3 * 83872 Door Hinge Pin 1 * 68229 Blower Motor Assembly 1 * 83339 Blower Mounting Bolts (1/4-20x3/4") 5 * 83340 Blower Clip Nut (1/4-20"J") 5 * 89319 Blower Gasket 1 * 80154 Cord Strain Relief Bushing 1 * 80145 Blower Limit Control 1 * 80231 Junction Box Cover 1 * 80232 Power Supply Cord 1 * 68231 Limit Control Flex Conduit Assembly 13" * 68232 Blower Flex Conduit Assembly 18" * 85759 Owners Manual * 87064 Red Spray Paint * 89284 Silicone Sealant * Not Shown 13 MODEL 1303 (See Repair Parts List on Page 13) 5 1 14 9 10 41 38 7 6 3 2 39 4 2523 24 22 20 17 1418 16 13 15 26 37 34 35 33 3231 36 28 27 40 19 8 30 12 21 42 11 29 2" MIN. AIR SPACE REQUIRED BY CODE 18" MIN. CENTRAL FURNACE 2" MIN. AIR SPACE REQUIRED BY CODE 18" MIN. CENTRAL FURNACE Fig. 10 Power Failure Instructions: Operation after loss of power- 1. Remove filter if provided 2. Do not expect to keep home at normal temperatures. 3. Do not load fuel above bottom of feed door. 15 Central Installation COLD AIR DUCT 6" PIPE DAMPER OPTIONAL 11 RPT 90 ELBOW FURNACE PIPE CONNECTOR Fig. 11 Add-On Installation COLD AIR DUCT 6" PIPE DAMPER 90 ELBOW FURNACE PIPE CONNECTOR EXISTING GAS/OIL/ELECTRIC FURNACE 8" PIPE FIG. 11-B 16 Operating Instructions FUEL, MODEL 1303 Hardwood, 18" to 26" should be split and air dried (seasoned) for 6 months. LIGHTING 1. Set the thermostat on "HIGH" for maximum draft. 2. Open the feed door and place paper and kindling on the grate for starting the fire. 3. Light fire and close feed door. 4. Add wood after fire is burning briskly. Be careful not to smother the kindling fire. 5. Set thermostat for desired temperature. "MEDIUM" setting is normally satisfactory. Set higher or lower for your comfort. ADDING FUEL When starting a fire, use small amounts of fuel. This will allow for more complete combustion and less buildup of tars or soot in the chimney. 1. Set thermostat to HIGH before opening feed door. 2. Wood Fire-Model 1303- Add wood to a convenient level. WARNING! NEVER STORE FLAMMABLE LIQUIDS, ESPECIALLY GASOLINE, IN THE VICINITY OF THE FURNACE. ADJUSTING BLOWER LIMIT CONTROL SETTINGS The temperature in the plenum of the warm air furnace at which the blower turns on or turns off, is contro...

Otros modelos de este manual:
Eléctrico - AIR (138.13 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría