Manual de usuario Berner International, modelo B-22

Fabricar: Berner International
Tamaño del archivo: 428.2 kb
Nombre del archivo: 7df54b05-4794-4d9b-9e21-9e9eed931cc0.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The propeller is a special Ductaxial solid aluminum casting, direct connected to an industrial duty,totally enclosed motor. The burner is the product of many years of experience in the crop drying fieldwithdirect-firedburners. Products of combustion, which are discharged directly into the main airstream, consist of carbon dioxide and water vapor. At maximum rated heat output the concentration Of C02 is approximately 2000 PPM (parts per million) compared with a maximum allowable* of 5000 PPM. Although the water vapor of combustion is added, relative humidity is actually reduced, owing to the heat that is added to theair.At maximum rated heat output, and assuming 60. F. saturated entering air, the discharge air is less than 5% RH. I II. MOUNTING POSITIONS (A) Burner: The standard unit may be installed at any angle between horizontaland vertical down airflow.The control cabinet is on the left-hand side, facing the airstream. The back panel of the cabinet must lie in a vertical plane; (i.e., the burner house cannot be rotated, thus rolling the cabinet toward the top or bottom of the burner house). (B) Plumbing: The gas piping elbows up and into the burner house on the bottom centerline. During installation, by loosening the union just outside the heater,the piping train may be rotated to any desired direction, provided valves are properly oriented. (See CAUTION) I III. INSTALLATION (MECHANICAL) One Door Heater will handle up to approximately a 12' x 15' door opening. Larger opening require two or more heaters. CAUTION: No door heater can substitute for a Tempered Intake Air Unit. If in-plant negative pressure exists because of exhaust ventilation, makeup air must be provided before a door heater can be expected to function properly. See your Berner representative. The heater should be aimed at a spot on the floor about four or five feet inside, and midway across, the door.Atthe inletend there should be no obstructions to the airflow closer than 20" -24"; at the outlet end, of course, there should be nothing obstructing the airstream. Around the sides of the heater there should be no combustible material closer than three feet. IV. GAS PRESSURE REGULATO R Gas supply pressure must be specified at the time of ordering, so that the proper regulator can be furnished to reduce line pressure to 6” - 8” W.C. It is suggested that a 1/8" or 1/4" I.P.S. test connection be provided in the gas supply line upstream of the regulator to facilitate taking pressure readings at time of startup and adjustment of burner equipment. Make sure that the regulator is installed in the line with the arrow on the body pointing in the direction of the flow of the fuel. With the regulator properly installed in the line, the following procedure is suggested when ready to light off and adjust the burner. (A) Remove the “top cap” of the regulator and check for shipping block or rod installed between spring and top cap. Remove, if found. (B) Remove plug, in vent opening of diaphragm housing. (Connect vent to atmosphere, if required by plant or insurance regulations. See Suggestions for Regulator Venting). The setting of the spring beneath the “top cap” on the regulator determines the outlet pressure. Screwing in on it increase the outlet pressure. Screwing out reduces the outlet pressure. The outlet pressure from the regulator will not necessarily be the same at full fire as under static conditions of no flow. Therefore, when adjusting gas pressure to very heat output, do so with the heater in operation. (See Maintenance.) Although most regulator problems in the field have to do with insufficient pressure at the outlet (usually because of line losses), it is well to know what to do in case the regulator won’t deliver a low enough pressure: Turning it upside down in the line will frequently do the trick. V. SUGGESTIONS FOR REGULATO R VENTING (See also Safety Devices on vent valve) One purpose of the vent connection is to provide a safe means of venting gas if the regulator diaphragm should fail. The vent also provides relief from the space above the diaphragm as it moves during regulation. A restriction in the vent line can result in poor regulator performance. The vent line should normally be piped outside the building, with as short a run of pipe as possible. There should be a minimum number of bends, and the pipe should be as large as practical, using the vent hole size as a guide. When tubing is used (on the smaller regulators), care must be exercised to avoid sharp bends and the resultant reduction in area. Grouping vent lines together into a common header is not normally recommended. If they must be grouped, the header 2 cross-sectional area should be at least equal to the sum of the individual vent areas. The outside end of the vent line should either have a weatherproof vent cap or should be directed downward for weather protection. It should also be screened to prevent foreign material or insects from entering the line. Naturally, the en...

Otros modelos de este manual:
Eléctrico - B-24 (428.2 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría