|
Manual de usuario Raypak, modelo RP2100 ASME Series
Fabricar: Raypak Tamaño del archivo: 71.8 kb Nombre del archivo: f37f92de-c6fc-4741-b39c-125ed640ac72.pdf
Idioma del manual:
|
|
|
|
Enlace gratuito para este manual disponible en la parte inferior de la página
Resumen del manual
Pressure Relief Valve ► Small Footprint ► Unitherm Governor Anti-Condensation Control ► Internal Bypass for High Flow Rates (up to 125 gpm) ► Indoor/Outdoor Digital model with outdoor top shown Heat Exchanger ■ ASME Inspected and Stamped 160 PSIG ■ National Board Approved ■ Glass-lined Cast Iron Headers ■ Finned Tubing □ Copper - Standard □ Cupro Nickel - Optional ■ ASME Steel Tube Sheet ■ Silicone O-Rings ■ 125 PSIG Pressure Relief Valve ■ Water Connections □ Right Hand - Standard □ Left Hand - Field Change ■ Flow Configuration - Two-pass Controls - Millivolt Option ■ Standing Pilot Ignition ■ Thermopile Generator ■ Single Mechanical Sensor ■ Flame Rollout Switch ■ High Limit Control ■ On/Off Switch ■ Water Pressure Switch Controls - Digital Option ■ 115/230V, 60Hz, 1 Ph Power Supply ■ 115/230/24V Transformer ■ 100% Pilot Shut-off; Lockout -Propane units only ■ Electronic, Intermittent Ignition Pilot (IID) ■ High Limit Control ■ On/Off Switch ■ Flame Rollout Switch ■ Water Pressure Switch ■ Dual Electronic Temp Sensor ■ Digital Display With Diagnostics Gas Control Train ■ Fuel □ Natural Gas □ Propane ■ Combination Control Valve ■ On/Off Firing ■ ANSI Z21.56 Design Certified Construction ■ Front Controls ■ Stainless Steel Burners ■ Polytuf Powder Coat Finish ■ Indoor/Outdoor ■ Vent Selection □ Outdoor Stackless Top - Standard □ Indoor Draft Diverter- Loose □ D-2 Power Vent - Loose ■ Base (Optional) □ Combustible Floor Shield Catalog No.: 6000.49 Effective: 3-15-04 Replaces: NEW RP2100 - ASME Series Atmospheric Pool Heaters Model Heater Model BTUH Input (000) (A) Cabinet Width (B) Flue Dia. (C) Indoor Drafthood (J) Gas Conn. Water Conn. Shipping Weights (lbs) Heater with Stackless Top Indoor Drafthood R185B 181 18-1/4” 6” 62-5/8” 12-1/16” 3/4" 2” 191 12 R265B 264 22-3/8” 7” 62-7/8” 11-1/8” 3/4" 2” 214 15 R335B 334 25-3/4” 8” 63-3/4” 10-3/4” 3/4" 2” 234 17 R405B 399 29-1/4” 9” 65-3/8” 12-1/2” 3/4" 2” 253 20 NOTES: Model number suffix indicates pilot type (E = digital, M = millivolt) and fuel type (P = propane, N = natural gas). Prefix “C” indicates Cast Iron (ASME) headers. Example: Model number CR-405B-EN indicates an ASME unit with digital (IID) ignition using natural gas. Ratings are for natural gas and elevations up to 2,000 feet above sea level. Reduce input 4% for each 1,000 feet above sea level when installed at over 2,000 feet elevation. Manufactured under Patent No. 3,623,458. Raypak, Inc. ■ 2151 Eastman Avenue, Oxnard, CA 93030 ■ (805) 278-5300 ■ Fax (800) 872-9725 ■ Raypak Canada Ltd. ■ 2805 Slough St., Mississauga, Ontario, Canada L4T 1G2 ■ (905) 677-7999 ■ Fax (905) 677-8036 ■ Catalog No.: 6000.49 Effective: 3-15-04 Replaces: NEW...
|