Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Lennox International Inc., modelo G21 V SERIES

Fabricar: Lennox International Inc.
Tamaño del archivo: 119.45 kb
Nombre del archivo: cd129e9f-1e7b-49fc-af81-874465f64d7c.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


This reverse flow ofthe flue gas may result in incomplete combustion and the formation of carbon monoxide gas. This toxic gas might then be distributed through the house by the furnace duct system. Your furnace is a gas appliance. It is critical that the gas supplied to the unit be completely burned to avoid the production of carbon monoxide gas. Complete combustion ofthe gas requires, but is not limited to, correct gas pressure and gas flow rate, adequate combustion, air, and proper venting. Exposure to this gas can cause personal injury and even death to all occupants, including pets. Any item that is powered by or gives off heat from a combustion process (including lawn mowers, automobiles, and fireplaces) has the potential to produce carbon monoxide gas. Because of this, Lennox recommends the use of a carbon monoxide detector in your home, even ifyou do not own gas appliances. Reliable detectors are available at reasonable retail prices. Contact your independent Lennox dealer for more details about this investment in your safety. Your furnace is designed to meet standards set by national agencies, and to operate safely when properly installed and maintained. However, the unit's performance can be greatly impacted by the individual installation and the operating environment. It is your responsibility to ensure that this appliance is maintained. Proper maintenance is critical for your safety and the satisfactory operation of the product. Lennox strongly recommends annual inspection and maintenance of this appliance. Contact your independent Lennox dealer for an inspection by a qualified service technician. Unit Operation This appliance does not have a pilot. It is equipped with an ignition system which automatically lights the burner. Do not try to light by hand. A-Gas Valve Operation A WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or death. Gas Valve Operation for Robertshaw and White Rodgers Valves (Figures 2 and 4) A WARNING Carbon monoxide gas is invisible, odorless, and toxic Page 2 1- Set thermostat to lowest setting. See figure 3. 2- Turn off all electrical power to furnace. See figure 5. 3- This appliance Is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 4- Remove unit access panel. 5- On Robertshaw 7200 gas valve, depress lever on gas control and move to OFF and release. For White Rodgers 36E gas valves, move switch to OFF. Do notforce. 6- Wait five (5) minutes to clear out any gas. Smell for gas, including near the floor. If you then smell gas, STOP! Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you do not smell gas go to next step. 7- On Robertshaw 7200 gas valve, depress lever on gas control and move to ON and release. For White Rodgers 36E gas valves, move switch to ON. 8- Replace unit access panel. 9- Turn on all electrical power to unit. 10- Set thermostat to desired setting. See figure 3. 11- Ifthe furnace will not operate, follow the instructions “To Turn Off Gas To Unit” and call your service technician or gas supplier. B-To Turn Off Gas To Unit 1- Set thermostat to lowest setting. 2- Turn off all electrical power to unit if service is to be performed. 3- Remove heat section access panel. 4- On Robertshaw 7200 gas valve, depress lever on gas control and move to OFF and release. For White Rodgers 36E gas valves, move switch to OFF. 5- Replace unit access panel. Page 3 Servicing the Filter Inspect and clean air filters each month. Filters must be cleaned when dirty to assure proper furnace operation and maintain efficiency. A-Cleaning Reusable Foam Filter 1- Turn off electrical power to furnace. 2- Remove blower access panel. Wait for blower to stop. 3- Remove filter by sliding up and out of channel. 4- Wash filter with water and a mild detergent. For increased efficiency, filter media should be sprayed with Filter Handicoater when dry. Filter Handicoater is RP products No. 418 and is available as Lennox part No. P-8-5069. See table 1 for replacement filters. TABLE 1 G21 Model No. Filter Size Filter Part No. All Q-40,-60, Q3-80, Q4-80 and V3-60, -80 units 16” x 25” (406 x 635mm) P-8-7822 Q5-80 and all Q-100 units: and V5-80,-100 units 20” x 25” (508 x 635mm) P-8-7831 5- Reinstall filter. Slide filter into top channel and drop into lower channel. IMPORTANT-Do not replace foam reusable filters with throw-away type filters. 6- Replace blower access panel. Lubrication Motors are prelubricated for extended bearing life; no further lubrication is required. Service At the beginning of each heating season, the system should be checked as follows: 1- Examine the termination ends of the intake and exhaust lines for obstructions or blockages. 2- Check the intake and exhaust lines for holes, sagging or broken isolation hangers. If a sag is found i...

Otros modelos de este manual:
Eléctrico - G21Q (119.45 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría