Additional efficiency rating information can be found at EFFICIENCYRATINGCERTIFIED DESCRIPTION These compact units employ induced combustion, reliable hot surface ignition and high heat transferaluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications. These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation. These units are Category IV listed and may be vented either through side wall or roof applications using approved plastic combustion air and venr piping. WARRANTY Lifetime limited warranty on the heat exchanger. 10-year heat exchanger warranty on commercial applications. 5-year limited parts warranty. FEATURES • Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary. • Compact, easy to install, ideal height 33" tall cabinet. • Blower-off delay for cooling SEER improvement. • Easy access to controls to connect power/control wiring. • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation. • Low unit amp requirement for easy replacement application. • Single wire twinning or staging feature available. • All models are convertable to use propane (LP) gas. • Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. • 100% shut off main gas valve for extra safety. • 4 speed, direct drive PSC motor. • 24V, 40 VA control transformer and blower relay supplied for add-on cooling. • Hi-tech tubular aluminized steel primary heat exchanger. • Secondary heat exchanger made of corrosion resistant stainless steel materials. • Timed on, adjustable off blower capability for maximum comfort. • Blower door safety switch. • Solid removable bottom panel allows easy conversion. • Airflow leakage less than 1% of nominal airflow at ductblaster conditions. • No knockouts to deal with, making installation easier. • Movable duct connector flanges for application flexibility. • Quiet inducer operation. • Inducer rotates for easy conversion of venting options. • Fully supported blower assembly for easy access and removal of blower. • External air filters used for maximum flexibility in meeting customers IAQ needs. • Protection included from air intake, exhaust vent, or condensate blockage. • Patent pending self priming internal condensate trap design for easy installation. • Venting applications - may be installed as a either 2-pipe (sealed combustion) or single-pipe vent (using indoor combustion air. • No special vent termination required. • 1/4 turn knobs provided for easy door removal. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 400992-CTG-B-0708 FRONT33ALEFTSIDECombustionAirInletCondensateDrain(Downflow) VentOutletThermostatWiring28.5” GasPipeEntryElectricalEntryCondensateDrainThermostatWiringRIGHTSIDEVentOutletCondensateDrain(Downflow) 14” 1” 1.5” 23” CombustionAirInletGasPipeEntryElectricalEntryCondensateDrainOptionalReturnAirCutout(Eitherside) 29.5” CSUPPLYEND.56” .56” 20” B3”23.8” .56” CombustionAirInletVentOutletRETURNENDB24.25” Cabinet & Duct Dimensions BTUH (kW) Input Nominal CFM (m3/min) Cabinet Size Cabinet Dimensions (Inches) Approximate Operating Weights A B C Lbs TG9S040A08MP11 800 A 14 1/2 13 3/8 11 3/4 113 TG9S060A10MP11 1000 A 14 1/2 13 3/8 11 3/4 118 TG9S060B12MP11 1200 B 17 1/2 16 3/8 13 1/4 122 TG9S080B12MP11 1200 B 17 1/2 16 3/8 14 3/4 126 TG9S080C16MP11 1600 C 21 19 7/8 16 1/2 136 TG9S080C22MP11 2200 C 21 19 7/8 16 1/2 139 TG9S100C16MP11 1600 C 21 19 7/8 18 1/4 142 TG9S100C20MP11 2000 C 21 19 7/8 18 1/4 145 TG9S120D16MP11 1600 D 24 1/2 23 3/8 21 3/4 153 TG9S120D20MP11 2000 D 24 1/2 23 3/8 21 3/4 156 TG9S130D20MP11 2000 D 24 1/2 23 3/8 No Hole 160 Ratings & Physical / Electrical Data Input Output Nominal Airflow Total Unit Amps AFUE Air Temp. Rise Max Over-Current Protect Min. wire Size (awg) @ 75 ft one way Max. Outlet Air Temp MBH CFM °F °F TG9S040A08MP11 38 800 8.0 95.5 30-60 15 14 155 TG9S060A10MP11 57 1000 10.0 95.5 30-60 15 14 155 TG9S060B12MP11 57 1200 10.0 95.5 30-60 15 14 160 TG9S080B12MP11 76 1200 10.0 95.5 35-65 15 14 165 TG9S080C16MP11 76 1600 11.5 95.5 35-65 15 14 155 TG9S080C22MP11 76 2200 17.0 95.5 35-65 20 12 155 TG9S100C16MP11 95 1600 11.5 95.5 35-65 15 14 165 TG9S100C20MP11 95 2000 17.0 95.5 35-65 20 12 155 TG9S120D16MP11 114 1600 11.5 95.5 40-70 15 14 170 TG9S120D20MP11 114 2000 17.0 95.5 35-65 20 12 160 TG9S130D20MP11 123.5 2000 17.0 95.5 45-75 20 12 165 Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edi...