Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Mr. Heater, modelo MH35LP

Fabricar: Mr. Heater
Tamaño del archivo: 196.43 kb
Nombre del archivo:
Idioma del manual:enfr
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Consult with your local LP-Gas dealer for details concerning proper equipment and installation. Piping must be clean and free from scale or burr. Before attempting to ignite the appliance, all gas fittings and connections must be thoroughly checked for gas leaks. Apply a small amount of a mild soap and water solution to all fittings and connections and observe for escaping bubbles. If any leaks are detected, shut off the gas supply to the appliance immediately. Wait a minimum of five minutes, repair the leak(s) and retest for leakage. Dry all fittings and connections after leak testing. WARNING NEVER USE A FLAME FOR GAS LEAK TESTING. OPERATING INSTRUCTIONS WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTION EXACTLY, A FIRE OREXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. CAUTION THIS APPLIANCE IS HOT DURING NORMAL OPERATION. AVOID PHYSICAL CONTACT. CAUTION DO NOT PLACE CLOTHING OR OTHER COMBUSTIBLE MATERIALS ON THIS APPLIANCE. DO NOT operate this heater if any part has been under water. Call a qualified service technician to inspect the appliance and to replace any part of the control system or gas control valve which has been under water. This appliance must be installed and operated only in locations where the potential for physical damage to the appliance is reduced to a minimum. The owner/operator of this appliance must ensure that precautions are taken to protect the appliance from physical damage. LIGHTING AND SHUT-DOWN Lighting the Heater: 1. Before attempting to light the heater, smell all around the heater area for gas. Be sure to smell next to the floor because LP-Gas is heavier than air and will settle on the floor. Turn on the gas supply to the appliance and check all fittings and connections for gas leaks using a mild soap and water solution. NEVER use a match to check for gas leaks. Should a gas leak occur, shut off the gas supply to the appliance immediately. Wait a minimum of five minutes before repairing the leak. 2. Use only the fuel intended for this appliance. Check the appliance rating plate for the correct fuel information. 3. Turn off the main gas supply to the appliance. Wait five minutes. 4. Turn on the main gas supply. 5. Depress red spark ignition button repeatedly or with a lighted match held to the burner face, depress and hold the reset button on the safety valve. After the burner ignites, hold the reset button depressed for about one minute or until the burner stays lit when the reset button is released. DO NOT light the gas at the burner orifice. DO NOT face heater when attempting to light. Always stand to the side of the unit when lighting. NOTE: In cases where long runs of gas supply lines have been installed ahead of the appliance, it may be necessary to bleed trapped air out of the supply lines before lighting the burner. New installations generally require bleeding of supply lines. Wait a minimum of five minutes after bleeding the supply lines before attempting to light the heater. 6. IMPORTANT: DO NOT attempt to adjust the main burner input using the main gas supply valve, for this may cause the thermocouple to shut down the burner. Enerco Group, Inc. | Gas-Fired Infra-Red Portable Construction Heater 4 Operating Instructions and Owner’s Manual Expanded Metal Screen Burner Face Reflector Thermocouple Control Cylinder Gas Valve Propane Gas Cylinder Regulator Expanded Metal Screen Burner Face Reflector Thermocouple Control Cylinder Gas Valve Propane Gas Cylinder Regulator To turn the heater OFF: 1. Close the LP-Gas supply cylinder valve. 2. Observe the burner until flame is extinguished. 3. Listen for closure of the safety valve. 4. IMPORTANT: DO NOT re-open the LP-Gas supply cylinder valve before the safety valve closes. MAINTENANCE INSTRUCTIONS This heater (including hose and regulator assembly) must be inspected before each use. If the hose for Model 35LP shows evidence of excessive abrasion or wear, or if the hose is cut, it must be replaced prior to the heater being put into operation. The replacement hose assembly shall be that specified by the manufacturer. See the parts list. The appliance area must be kept free and clear of combustible materials, gasoline and other flammable vapors and liquids at all times. The flow of combustion and ventilation air must not be obstructed. Cleaning the heater: Periodically, the heater must be cleaned of all dirt and dust particles. DANGER DO NOT ATTEMPT TO CLEAN THE HEATER WHILE IT IS OPERATING OR WHILE IT IS STILL HOT. • Turn the heater off and wait until it has completely cooled (at least 20 minutes) before cleaning. • Clean the outside of the heater using a damp cloth. DO NOT clean the heater by spraying water on it. Wipe the outside of the heater off with a dry cloth after cleaning. • Clean the inside of the heater using compressed air. Blow air back and forth along the entire burner face until all dust has been dislodged from the surface of the reverberator and grid screen. Blow through venturi f...

Otros modelos de este manual:
Eléctrico - HS35LP (196.43 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría