|
Resumen del manual
Theinstallationmustcomplywithregulationsoftheservinggassupplier, localbuilding, heating, plumbing, andothercodes. Inabsenceoflocalcodes, theinstallationmustcomplywithnationalcodesandallauthoritieshavingjurisdiction. B24.25” .56” .56” 20” 3” 23.8” .56” CombustionAirInlet2” DiameterVentConnectionOutletBDURINGINSTALLATION, DOORSMUSTREMAINONFURNACEWHENMOVINGORLIFTING. VentConnectionOutlet † Other airflows are available. see Tech Guide for all CFM options. * Cool Tap. ** Adjustment Tap. LED INDICATOR CLEARANCES DIMENSIONS Slow Green Flash - Normal operation in standby mode. Slow Amber Flash - Normal operation with call for cooling. Two Amber Flashes - Normal operation with call for heat. Three Amber Flashes - Normal operation, burner is on at end of thermostat cycle. Six Amber Flashes - Normal operation with call for heat pump heating. Any Red Flash - Fault condition. NOTE: 4 or 5 flashes may indi cate a blown fuse on the circuit board. Application Upflow Downflow Horizontal Top 1" 0" 0" Vent 0" 0" 0" Rear 0" 0" 0" Side 0" 0" 1" Front* 0" 0" 0" Floor Combustible Combustible1 Combustible Closet Yes Yes Yes Line Contact No No Yes Cabinet Size A (in) B (in) All ' B' Cabinet Furnaces 17-1/2" 16-3/8" All ' C' Cabinet Furnaces 21" 19-7/8" All ' D' Cabinet Furnaces 24-1/2" 23-3/8" Subject to change without Printed in U.S.A. 438336-URG-A-0209 1. For combustible floors only when used with special Copyright © 2009 by Johnson Controls, Inc. All rights reserved. *438336* Supersedes: Nothing sub-base. * 24" clearance in front and 18" on side recommended for Johnson Controls Unitary Products service access. 5005 York Drive All furnaces approved for alcove attic installation. Norman, OK 73069 For 100 & 120K input furnaces, the condensatedrain is factory set toward the left casing outlet. 1 For 100 & 120K input furnaces, the condensatedrain is factory set toward the left casing outlet. 1 MOST COMMON INSTALLATION CONFIGURATIONS (MORE OPTIONS AVAILABLE WITH INDUCER ROTATION, WHICH IS COVERED IN THE INSTALLATION MANUAL) MULTI-POSITION CONFIGURATION INFORMATION: Ensure that all PVC venting has at least 1/4” per foot slope towards the furnace. 1 Move rain gutter hose Furnace is multi-position and may be installed in any of the configurations shown. The furnace condensate pan is self priming and contains an internal trap. Do not install an external condensate trap. When drain hose routing changes are required (shown in red), be sure to cap all unused openings. If rerouting hoses - excess length should be cut off so that no sagging loops will collect and hold condensate, which will cause the furnace to not operate. to this position. HORIZONTAL LEFT Move pressure switch hose to this position. NOTE: May require the longer hose that is provided with wider cabinets. Change condensate drain connection to the 90° fitting provided. Move condensate drain hose to this position. Move rain gutter hose to this position NOTE: May require hose extension that is provided with wider cabine...
Otros modelos de este manual:Eléctrico - TM9V060B12MP11 (234.01 kb)
Eléctrico - TM9V080C16MP11 (234.01 kb)
Eléctrico - TM9V100C16MP11 (234.01 kb)
Eléctrico - TM9V100C20MP11 (234.01 kb)