Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Empire Comfort Systems, modelo GWT-50-2

Fabricar: Empire Comfort Systems
Tamaño del archivo: 1.08 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Insert header plate with attached 4" oval, double wall vent pipe into wall opening. Position header plate at height shown in Figure 2. Locate rear edge of nailing .ange at the back of the 2" x 4" stud which will center the vent collar in the wall. Locate the angled edge of header plate .ush with the top of the wall opening. Nail header plate to the wall studs. Replace and attach header extension onto header plate with 2 screws. Page 8 12426-4-0104 12426-4-0104 Page 9 Figure 2 FINISHING INSTRUCTIONS Plastering (Figure 4) In new construction use only plain (not perforated) gypsum lath around furnace and vent pipe so that plaster "Keys" will not project into wall space. Use wood strips nailed to inside of studs and top of bottom plate. These must be removed before installation of furnace. Lath and plaster against top projection of Header Plate. Do not allow wall . nish materials to project into furnace recess.. Figure 4 Installing Furnace (Figure 5) Clear the recess of all debris, and remove any wood plaster-grounds. Stand the furnace on . oor in front of wall opening. Insert furnace . ue into rectangular opening in header plate and raise furnace carefully (see Figure 5). Swing bottom of furnace into wall opening with back of legs . ush with rear of . oor plate. Secure furnace support legs to the . oor plate. Figure 5 Page 10 12426-4-0104 IMPORTANT . Avoid securing too tightly and disturbing the inner casing. Do not try to force furnace into a wall opening which is smaller than speci. ed dimension. OUTER CASING (Figure 6) 1. Align 1 3/4" slot on casing bracket with bottom screw hole on inner casing. Attach casing bracket to inner casing with one (1) 10 x 1/2" screws for each casing bracket. Do not completely tighten screws at this time. 2. Place outer casing onto header. Attention: Use center clearance hole on outer casing top for attachment to header with one (1) 8 x 3/8" Phillips screw when optional blower is not installed. Attention: Use outside clearance holes on outer casing top for attachment to header with two (2) 8 x 3/8" Phillips screws when optional blower is installed. 3. Align clearance holes on outer casing bottom with screw holes on casing brackets by adjusting slots on casing brackets. 4. Complete tightening casing bracket screws from Step 1 to inner casing at this time. 5. Attach outer casing to casing brackets with two (2) 10 x 1-1/2" screws. INSTALLING CONTROL DOOR Attach two washers supplied in hardware package to pivot pins located at bottom of control door. Install control door to outer casing assembly. FINISHING INSTRUCTIONS (continued) Figure 6 THERMOSTAT LOCATION (SG MODELS) THERMOSTAT LOCATION (SG MODELS) CAUTION . Do not run wire behind .anges of Header Plate Connect thermostat wires to gas valve as shown in Figure 7. or in any location where it might be damaged. Millivolt wall thermostats are specially designed for use on self- generating systems. They should never be used on line or low voltage A.C. circuits. Interior Wall . The thermostat should be installed on an inside wall away from the furnace but in the same room. Note: Use 16 gauge wire to prevent excessive loss of millivolts. Proper operation depends on a good pilot . ame. The . ame must cover the top of the thermopile. Cleaning of the pilot ori. ce and burner may be required due to spiders. Figure 7 System Check (Figure 7) A millivolt meter is required to check the system. Millivolt readings should be: . Across the thermopile terminals, 400-450 millivolts with thermostat OFF. . Across the thermopile terminals, 150-250 millivolts with thermostat ON. . Across the thermostat wires at the valve, less than 30 millivolts with thermostat ON. . Across the thermostat wires at the thermostat, less than 5 millivolts with thermostat ON. (Dirty pilot or low pressure will reduce readings.) 12426-4-0104 Page 11 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a .re or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. phone. Follow the gas supplier’s instructions. . If you cannot reach your gas supplier, call the .re department. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the . oor because some gas is heavier than air and will settle on the . oor. WHAT TO DO IF YOU SMELL GAS C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it; call a quali.ed service technician. Force or attempted repair may result in a .re or explosion. . Do not try to light any appliance. . Do not touch any electrical switch; do not use any phone in your building. . Immediately call your gas supplier from a neighbor’s D. Do not use this appliance if any part has been under water. Immediately call a quali.ed service te...

Otros modelos de este manual:
Eléctrico - RB) (1.08 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría