Iniciar sesión:
Votos - 4, Puntuación media: 4.3 ( )

Manual de usuario Gas-Fired Products, modelo Tube Series PTU

Fabricar: Gas-Fired Products
Tamaño del archivo: 1.4 mb
Nombre del archivo: PTS-PTU-Series-Spec-Sheet(S45600)-Rev-8-08.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


INNOVATIVETUBEINTEGRITYSAFETYSYSTEM*(TISS™) Space-Ray’snewlydevelopedTubeIntegritySafetySystem* (TISS)providespeaceofmind.Itmayneverbeneeded,butintheunlikelyeventofatubefailure,youwillbehappythatyouhaveaTISS.Itissimple.Alowvoltagecircuitcontinuouslymonitorstheclearanceabovethereflectorforexcessiveoverheatandtubeintegritycompromise.Youmayneverknowitisthere,butonapositivepressuretubeheateritisnicetoknowyouhavetheTISS. LowVoltageCircuitControlTopofReflector10’LongAluminumWire& SleeveAssemblySpringRetainerClamp*US&WorldwidePatentsPendingDIMENSIONSSpringHowtheTISS™WorksSpace-Ray’sinnovativesafetyfeatureTISSprovidestheultimateinfiresafetyprotectionavailableforpositivepressureradianttubeheaters.Intheunlikelyeventthattheheatexchangertubeburnsthrough,aflamewillpenetratethetube, meltthereflector,andrapidlyincreasethetemperatureabovetheheater.Theexposedflamewillpotentiallysetfiretoanycombustiblematerialsthatwerepreviouslysafedistancesawayfromtheheater.TherevolutionaryTISSusesasimpleprincipletoplaceanelectricallychargedinsulatedaluminumwireintensionabovethereflector.Whentheheatincreasesduetoheatexchangerfailure,thewiremelts,thesafetycircuitisbrokenandshutsdownthegascontrols. INNOVATIVETUBEINTEGRITYSAFETYSYSTEM*(TISS™) Space-Ray’snewlydevelopedTubeIntegritySafetySystem* (TISS)providespeaceofmind.Itmayneverbeneeded,butintheunlikelyeventofatubefailure,youwillbehappythatyouhaveaTISS.Itissimple.Alowvoltagecircuitcontinuouslymonitorstheclearanceabovethereflectorforexcessiveoverheatandtubeintegritycompromise.Youmayneverknowitisthere,butonapositivepressuretubeheateritisnicetoknowyouhavetheTISS. LowVoltageCircuitControlTopofReflector10’LongAluminumWire& SleeveAssemblySpringRetainerClamp*US&WorldwidePatentsPendingDIMENSIONSSpring PTS -BOTTOM VIEW PTS -END VIEW 13” 6” MODEL TOTAL TUBE LENGTH (FT) OVERALL DIMENSION “L”(FT) PTS (40) 10’ 11’ 2” PTS (40, 50, 75) 20’ 21’ 2” PTS (50, 75,100,125) 30’ 31’ 2” PTS (100, 125, 150) 40’ 41’ 2” PTS (125, 150, 175, 200) 50’ 51’ 2” PTS (150,175,200) 60’ 61’ 2” PTS (200) 70’ 71’ 2” PTU -BOTTOM VIEW PTU -END VIEW 18” 31” 6” MODEL TOTAL TUBE LENGTH (FT) OVERALL DIMENSION “L” (FT) PTU (40, 50, 75) 20’ 12’ 5” PTU (50, 75,100, 125) 30’ 17’ 5” PTU (100, 125, 150) 40’ 22’ 5” PTU (125, 150, 175, 200) 50’ 27’ 5” PTU (150,175, 200) 60’ 32’ 5” PTU (175, 200) 70’ 37’ 5” PTS AND PTU BURNER BOX PTS OPTIONS Burner Box Dimensions (10” W x 14” L x 14” H) 90. ELBOW CORNER REFLECTOR MODEL HEIGHT AT HORIZONTAL HEIGHT AT 45° ANGLE PTS/U 125 14 feet 13 feet PTS/U 150 15 feet 14 feet PTS/U 175 16 feet 15 feet PTS/U 200 18 feet 17 feet COMBUSTIONAIRANDVENTILATIONCombustionairandventingrequirementsforallgas-firedheatingequipmentmustbeprovidedpertheNationalFuelGasCodeNFPA54ortheauthorityhavingjurisdictionovertheinstallation.Incontaminatedatmospheresorhighhumidityareas,optionaloutsideairforcombustioncanbesupplied.Heaterscanbecommonvented,vented,orindirectvented. RefertotheInstallationandOperationInstructionsforfurtherinformation.Aventedinstallationmustbeventedtotheoutsideofthebuildingwithafluepipe.AnIndirectventedin- stallationrequiresaminimumventilationflowof4CFMper1000Btu/hroftotalinstalledheatercapacityonnaturalgasbyeithergravityorpowerventilation(4.18CFMper1000Btu/hrforpropane).Forindirectventedapplications,buildingexhaustopeningsmustbelocatedabovetheleveloftheheatersandinletairopeningsmustbelocatedbelowtheleveloftheheaters. FORYOURSAFETYOPERATESPACE-RAYGASINFRAREDHEATERSWITHPROPERCAREANDOBSERVEALLSAFETYPRECAUTIONS.Installationandservicemustbeperformedbyalicensedcon- tractor.Theinstallationmustconformtolocalcodes.Intheabsenceoflocalcodes,theinstallationmustconformtotheNationalFuelGasCodeANSIZ223.1(latestedition,alsoknownasNPFA54)orCAN/CSA-B149installationcodes(latestedition).ThesecodesareavailablefromtheNationalFireProtectionAssociation,Inc.,BatterymarchPark,Quincy,MA02269ortheCanadianGasAssociation,55ScarsdaleRoad,Toronto,OntarioMB32R3Canada. ThePTS/PTUseries,withmorethan100differentconfigurations,offersoptimumflexibilityincustomdesigninganinfraredheatingsystem.ThePTSseriesisavailableinmultipleconfigurations(straight,L,Z,andexpandedU-shape)withlengthsfrom10’to70’long.Foraddedversatility,90°elbows,cornerreflectors,andsidereflectorsareavailableforcloseareamountingnearwalls,doors,andcorners.ThePTUseriesisavailableinsevendifferentconfigurationsandprovidesmoreuniformradiantheatenergydistribution.ThePTUseriesisidealforhighheatlossareasandspotheating. PTS/PTUSERIESLAYOUTSMINIMUMRECOMMENDEDMOUNTINGHEIGHTSMINIMUMCLEARANCESTOCOMBUSTIBLESMODELPTS/U40PTS/U50PTS/U75PTS/U10010feet11feet13feet14feet9feet10feet12feet13feetPTS/U(40,50) PTS/U(75) PTS/U(100) PTS/U(125) PTS/U(150,175) PTS/U(200) MINIMUMCLEARANCESTOCOMBUSTIBLESMODELNO.SIDECEILINGBELOWEND(45°) FRONT(45°) REAR27” 27” 66” 66” 84” 86” 6” 6” 6” 6” 6” 18” 40” 60” 88”** 101”** 106”** 132”** 30” 30” 40” 40” 48” 48” 48” 48” 66” 66” 84” 84” 12” 12” 20” 20” 24” 24” *Whenusedindirectvented,clearancestoceilingfromtopofexhausthoodmustbe12”onPTS/U(50-75),and18”onPTS/U(100-200).Ifoptiona...

Otros modelos de este manual:
Eléctrico - Tube Series PTS (1.4 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría