Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Gas-Fired Products, modelo LTS 125

Fabricar: Gas-Fired Products
Tamaño del archivo: 1.33 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


will not recognize the warranty for any use other than space heating. Form #43155010 Feb-04 -1- This heater is for Indoor Installation and Covered Patio Installation only and can be used in either Vented or Unvented mode. The term Unvented actually means Indirect Vented. While the products of combustion are expelled into the building, national codes require ventilation in the building to dilute these products of combustion. This ventilation may be provided by gravity or mechanical means. This heater is not an explosion proof heater. Where the possibility of exposure to volatile and low flash point materials exists, it could result in property damage or death. This heater must not be installed in a spray booth where the heater can operate during the spraying process. Consult your local fire marshal or insurance company. LTS Series Onlv: Since straight tube heaters are always hotter at the control end than at the draft inducer end, always observe the minimum recommended mounting heights shown on the specification sheets and in Section 7 of this manual. Use U-tube configuration instead of straight tubes for spot or area heating (e.g., where a single heater is utilized for space heating). A WARNING: Certain materials or objects, when stored under the heater, will be subjected to radiant heat and could be seriously damaged. Observe the Minimum Clearances to Combustibles listed In the manual and on the heater at all times. ! ATTENTION: SAVE THIS MANUAL FOR FUTURE REFERENCE. 2) LTU 80-175 SERIES - SPECIFICATIONS Model No. Btu/hr Input Heat Exchanger Length Total Heater Length Flue Restrictor Plate I.D. & Part # Orifice Size Minimum Mounting Height Natural Gas Propane Gas @ Horizontal @ 45° Angle LTU80 80,000 30’ IT-6V2’ 1-1/2" #42741050 #19 (0.166) #38 (0.102) 12’ 12’ LTU90 90,000 1-1/2” #42741050 #16 (0.177) #36 (0.106) 12’ 12' LTU100 100,000 1-5/8” #42741060 #14 (0.182) #33 (0.113) 12’ 12’ LTU 110 110,000 1-3/4” #42741070 #10 (0.194) #31 (0.120) 14’ 13’ LTU120 120,000 1-3/4” #42741070 13/64 (0.203) 1/8 (0.125) 14’ 13' LTU125 125,000 1-7/8” #42741080 #5 (0.206) #30 (0.129) 14’ 13' LTU 130 130,000 1-7/8” #42741080 #4 (0.209) 3.3mm (0.130) 14’ 13’ LTU125* 125,000 40’ 22'-QW 1-7/8’ #42741080 #5 (0.206) #30 (0.129) 14’ 13’ LTU130* 130,000 1-7/8” #42741080 #4 (0.209) 3.3mm (0.130) 14’ 13’ LTU140* 140,000 2-1/32” #42741090 5.5mm (0.216) #29 (0.136) 15’ 14’ LTU150* 150,000 2-1/32” #42741090 5.7 mm (0.224) #28 (0.140) 15’ 14’ LTU 160* 160,000 2-1/4” #42741100 5.8mm (0.228) #27 (0.144) 15’ 14’ LTU 175* 175,000 2-1/4” #42741100 “C” (0.242) 3.8mm (0.150) 16’ 15’ * These models require the use of an additional 5’ body section. Type Gas-PIpe Tube Flue Fresh Air Electrical Current Gas: Connection: Diameter: Connection: Connection: Supply: Rating: Natural or Propane Vi” NPT (Female) 4” 6” Round 6’ Round 120 Volt, 60Hz, 1 Phase 2.6 Amp Fuse Rating: Ignition System: In-line: 2 Amp 250V (for...

Otros modelos de este manual:
Eléctrico - LTS 100 (1.33 mb)
Eléctrico - LTS 110 (1.33 mb)
Eléctrico - LTS 120 (1.33 mb)
Eléctrico - LTS 130 (1.33 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría