|
Resumen del manual
It is permissible to place the appliance on carpet. CAUTION Some carpet materials may be sensitive to radiant heat from the appliance causing discoloration or odor. Fire Risk. Odor Risk. Tipping Risk • Install appliance on a stable, level platform/ floor strong enough to support appliance without tipping. • USE wood flooring, ceramic tile, brick hearth or high pressure laminate flooring applied directly over the sub-flooring material. WARNING A H -Alcove A C D A B F A E "A" measurement is from stove top, not side C G NOTE: For actual appliance dimensions refer to Section 12. Page 8 Quadra-Fire · Garnet-T · 7016-127F September 1, 2008 4Termination Locations A. Vent Termination Minimum Clearances Gas Termination Wood & Fuel Oil Termination Comments A 6 in. 20 in. min. Horizontal distance between terminations B 20 in. 24 in. min. Distance to perpendicular wall C 18 in. 18 in. Vertical distance between terminations C A GAS TERMINATION B GAS, WOOD OR FUEL OIL TERMINATION Figure 4.2 Multiple Vertical Termination Figure 4.1 Termination Clearances Figure 4.3 specifies minimum vent heights for various pitched roofs. Figure 4.3 Minimum Height from Roof to Lowest Discharge Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as specified. WARNING • Do not pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause fire. HORIZONTAL OVERHANG VERTICAL WALL GAS DIRECT VENT TERMINATION CAP 12 X ROOF PITCH IS X/ 12 LOWEST DISCHARGE OPENING 2 FT. MIN. 20 INCHES MIN. H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Roof Pitch H (Min.) Ft. Flat to 6/12 ........................................................ 1.0* Over 6/12 to .7../.1..2................................................. 1.25* Over 7/12 to 8/12 .............................................. 1.5* Over 8/12 to 9/12 .............................................. 2.0* Over 9/12 to 10/12 ............................................ 2.5* Over 10/12 to 11/12 ........................................... 3.25 Over 11/12 to 12/12 ........................................... 4.0 Over 12/12 to 14/12 ........................................... 5.0 Over 14/12 to 16/12 ........................................... 6.0 Over 16/12 to 18/12 ........................................... 7.0 Over 18/12 to 20/12 ........................................... 7.5 Over 20/12 to 21/12 ........................................... 8.0 * 3 foot minimum in snow regions Measure vertical clearances from this surface. Measure horizontal clearances from this surface. (See Figure 4.4 for specific clearances.) Opening (See Note 2) Electrical Service V SV S V T D* V D BL v v v v v v v v B BA H M X J or K I A G F U.S. (3 FT)B M N P R Q Electrical Service V SV S V T D* V D BL v v v v v v v v B BA H M X J or K I A G F U.S. (3 FT)B M N P R Q V = VENT TERMINAL X = AIR SUPPLY INLET A = 12 inches ............. clearances above grade, veranda, porch, deck or balcony(See Note 1) B = 12 inches ............ clearances to window or door that may be opened, or to permanently closed window. (Glass) D* = 18 inches ............. vertical clearance to unventilated soffit or to ventilated soffit located above the terminal *30 inches ............ for vinyl clad soffits and below electrical service F = 9 inches .............. clearance to outside corner G = 6 inches ............... clearance to inside corner H = 3 ft. (Canada) ...... not to be installed above a gas meter/regulatorassemblywithin 3 feet (90cm) horizontally from the center-line of the regulator I = 3 ft. ....................... clearance to gas service regulator vent outlet J = 9 inches (U.S.A.) 12 inches (Canada)clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance ** a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. *** only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor, or meets Note 2. NOTE 1: On private property where termination is less than 7 feet above a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap is suggested. (See vents components pages.) NOTE 2: Termination in an alcove space (spaces only open on one side and without an overhang) are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be at least 3 feet minimum between termination caps. 2. All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap. 3. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap. NOTE 3: Location of the vent termination must not interfere with access to the electrical service. Figure 4.4 = AREA WHERE TERMINAL IS NOT PERMITTED K = 3 ft. (U.S.A.) 6 ft. (Canada) ......... clearance to a mecha...
Otros modelos de este manual:Eléctrico - GARNET-T GARNET-D-CSB (3.18 mb)
Eléctrico - GARNET-T GARNET-D-MBK (3.18 mb)
Eléctrico - GARNET-T GARNET-D-PMH (3.18 mb)
Eléctrico - GARNET-T GARNET-MBK (3.18 mb)