Iniciar sesión:
Votos - 1, Puntuación media: 5 ( )

Manual de usuario Louisville Tin and Stove, modelo VFT102

Fabricar: Louisville Tin and Stove
Tamaño del archivo: 416.25 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Release the gas control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 2 thru 7. • If knob does not pop up when released, STOP and immediately call your service technician or gas supplier. • If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 9. Turn on all electric power to the appliance. 10. Turn gas control knob counterclockwise to desired temperature setting. TO TURN OFF GAS TO APPLIANCE 1. Depress gas control knob slightly and turn clockwise to “OFF”. 2. Turn off all electric power to the appliance if service is to be performed. Gas Control Knob NOTE: Knob can not be turned from “PILOT” to “OFF” unless knob is depressed slightly. Do not force. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to the next step. 5. Locate pilot in the cut-out below the burner. 6. Locate piezo ignitor button on top of heater. Page 14 PROPER OPERATION ODS / PILOT FLAME The pilot pressure has been pre-set at the factory and with proper supply pressure will provide a safe, reliable ignition source. See Figure 6. CORRECT INCORRECT INCORRECT - OXYGEN LOW PRESSURE LEVEL DROPPING BURNER FLAME All orificing and pressure setting was done at the factory and, with proper supply pressure, will provide a safe, efficient source of heat. However, if any questions about manifold pressure, have a qualified serviceman check with a manometer, Natural Gas will be 5”, L.P. Gas will be 10” w.c. A proper burner flame (See Figure 7) will produce a reddish-orange flow on the surface of the ceramic burner plaques. If the burner flame has blue streamers or the flame is floating off the surface of the plaques, turn heater off and call a qualified service person. Do not operate heater if all plaques are not glowing. NOTE: There will be approximately .” space on the sides and top of the burner that will not glow. VFM20: When turned to the “LO” setting the two middle plaques will light and glow. When valve is turned to “HI” then CORRECT FLAME all four plaques will be lit. FIGURE 7 INCORRECT FLAME VFM20 / CORRECT FLAME “LO” VFM20 / CORRECT FLAME “HI” Page 15 MAINTENANCE The entire heater should be checked and cleaned by a qualified service person before the start of each heating season. More frequent cleaning may be required due to excessive lint conditions from carpeting, bedding material, etc. CABINET To clean the cabinet and hearth and jamb assemblies of your heater, turn off and allow to cool, then wipe with a soft damp cloth. This will remove any dust. Never use metal polish, furniture wax, or any type of cleaning solution as this could cause odors when the heater is turned back on. MAIN BURNER Burners may be cleaned by using a low pressure air hose, or soft brush. Be careful not to damage the ceramic plaque. ODS/PILOT STEP 1. Remove bottom front panel. STEP 2. Disconnect pilot line from pilot. STEP 3. Use a low pressure air hose to blow through pilot and through ODS opening in side of pilot. WARNING: Never insert anything into any of the openings in the pilot as this could damage the Oxygen Depletion System and expose the homeowner to Carbon Monoxide poisoning. Apply Air STEP 3 - PILOT CLEANING WARNING: After any servicing or cleaning make sure heater is completely re-assembled and check for gas leaks. Page 16 BLOWER INSTRUCTIONS INSTALLING THE VFB BLOWER STEP 1. Remove blower assembly from shipping carton. STEP 2. Insert blower assembly into upper back of heater (See Figure 8). STEP 3. Secure blower to heater using three #8 screws (provided) through holes pre-punched in heater back. STEP 4. Locate mounting holes for switchbox (See Figure 8). STEP 5. Secure switchbox to heater using two #8 screws (provided). STEP 6. Plug p...

Otros modelos de este manual:
Eléctrico - VFM103 (416.25 kb)
Eléctrico - VFM104 (416.25 kb)
Eléctrico - VFM203 (416.25 kb)
Eléctrico - VFM204 (416.25 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría