Iniciar sesión:
Votos - 1, Puntuación media: 5 ( )

Manual de usuario Dimplex, modelo ELB20

Fabricar: Dimplex
Tamaño del archivo: 154.79 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


If the supply cord is damaged it must be replaced by the manufacturer or service agent or a similarly qualified person in order to avoid a hazard. Keep the supply cord away from the front of the heater. Introduction Unpack the heater carefully and retain the packaging for possible future use, in the event of moving or returning the fire to your supplier. These models are fitted with castors so they can moved from room to room with ease, and are normally positioned against a wall. A choice of 1kW or 2kW heat output is provided by the fan heater, which is located at the bottom of the unit. Before connecting the heater check that the supply voltage is the same as that stated on the heater. Please note: Used in an environment where background noise is very low, it may be possible to hear a sound which is related to the operation of the flame effect. This is normal and should not be a cause for concern. Electrical connection WARNING – THIS APPLIANCE MUST BE EARTHED This heater must be used on an AC ~ supply only and the voltage marked on the heater must correspond to the supply voltage. Before switching on, please read the safety warnings and operating instructions. In the event of replacing the fuse in the plug supplied, a 13 amp fuse approved by ASTA to BS1362 must be used. Operation The unique flame effect may be enjoyed whether or not the heating elements are in operation. Controls The heater controls are located behind the flap on the front of the heater. (see Fig 1). Three switches provide a choice of heat settings. A switch is in the ON position when the side with the markings on (i.e. I , I , or II ) is pushed in. OIIII Fig. 2 Switch 1 ( I ) Controls the electricity supply to the heater and flame effect Note: This switch must be in the ON ( I ) position for heater to operate with or without heat Switch 2 ( I ) Provides 1kW heat output Switch 3 ( II ) Provides 2kW output with switch 2 Maintenance WARNING – BEFORE UNDERTAKING ANY MAINTENANCE OR CLEANING REMOVE PLUG OR DISCONNECT FROM THE ELECTRICITY SUPPLY. Lamp Replacement four screws on removable back panel Fig. 3 Two lamps are located behind the back panel as indicated in Fig. 3. To gain access to the lamps, the four screws which secure the back panel, must be removed. Remove and slide out panel as indicated in Fig. 4. Fig. 4 Fig. 5 Remove the defective lamp by unscrewing it as shown -see Fig. 5. Replace with a 60W E14 SES Clear Candle lamp. Take care not to over-tighten the lamp. Refit the back panel and secure with the four screws. Safety cut-out An automatic cut-out will switch off the heater if for any reason it overheats. This could occur for instance, if the air inlet or outlet were restricted in any way. If the cut-out operates, the heater will switch off. The heater will switch on once the obstruction has been removed and the heater has cooled. If the cut-out continues to operate intermittently, the heater should be switched off and Customer Services contacted. Cleaning For general cl...

Otros modelos de este manual:
Eléctrico - DNB20 (154.79 kb)
Eléctrico - LAG20 (154.79 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría