Manual de usuario Desa, modelo BC70ET

Fabricar: Desa
Tamaño del archivo: 2.43 mb
Nombre del archivo:
Idioma del manual:enfr
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Extension Cord Size Requirement 6 to 10 feet (1.8 to 3 meters) long, use 18 AWG (0.75 mm2) rated cord 11 to 100 feet (3.3 to 30.5 meters) long, use 16 AWG (1.0 mm2) rated cord 101 to 200 feet (30.8 to 61 meters) long, use 14 AWG (1.5 mm2) rated cord 7. Plug extension cord into standard 120 volt/60 hertz, 3-prong grounded outlet. Note: For heater without ON/OFF switch, ignitor will preheat for five seconds, then heater will start. Note: For heater with ON/OFF switch, push switch to ON(|) position and heater should start in 5 seconds. If heater does not start, see Troubleshooting, page 9. 8. For thermostat models, adjust thermostat knob to the desired setting. Note: Acold heater may affect the thermostat setting. This thermostat is a general-heating control. It is not intended for precise temperature control.Adjust thermostat until heater cycles at the desired setting. TO STOP HEATER Without ON/OFF Switch Unplug extension cord from outlet. With ON/OFF Switch Push ON/OFF switch to OFF (O) position. Unplug heater when not in use. TO RESTART HEATER Without ON/OFF Switch 1. Unplug extension cord from outlet and wait 10 seconds. (Wait two minutes if heater has been running.) 2. Repeat steps under To Start Heater. With ON/OFF Switch 1. Push ON/OFF switch to OFF (O) position and wait 10 seconds (2 minutes if heater has been running). 2. Repeat steps under To Start Heater. Figure 8 - ON/OFF Switch, 55/70 Models ON/OFF Switch with ON/OFF Switch with Light Light Figure 9 - ON/OFF Switch, 115/165 Models 116170-01A OPERATION WITH PORTABLE GENERATOR WARNING: Before operating heater or any appliance from a portable generator, verify that generatorhasbeenproperlyconnectedtoearthground. Improper grounding or failure to ground generator can result in electrocution if a ground fault occurs. Refertoowner’smanualsupplied by generator manufacturer for proper grounding procedures. The operating voltage range of the heater is 108 to 132 Volts (120 Volts +/- 10%). Prior to plugging heater into generator the output voltage should be verified (if generator is equipped with the automatic idle feature, the output voltage should be measured with the generator running at full speed). If the voltage does not measure in this range the heater should not be plugged into the generator. Refer to Operation, page 6, for starting, stopping, and resetting heater procedures. Ground Lug Alternator Ground Wire (#10 AWG - Stranded- Copper) Copper or Brass Grounding Point Figure 10 - Typical Generator Grounding Method (Generator construction may vary from that shown) STORING, TRANSPORTING OR SHIPPING Note: If shipping, transport companies require fuel tanks to be empty. 1. Drain fuel tank. Note: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap opening. Be sure all fuel is removed. 2. Replace drain plug if provided. 3. If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters during future use. 4. Replace fuel cap or drain plug. Properly dispose of old and dirty fuel. Check with local automotive service stations that recycle oil. 5. If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes. IMPORTANT: Do not store kerosene over summer months for use during next heating season. Using old fuel could damage heater. 116170-01A PREVENTATIVE MAINTENANCE SCHEDULE WARNING: Never service heater while it is plugged in, operating or hot. Severe burns and electrical shock can occur. Item How Often How To Fuel tank Air output and lint filters Air intake filter Fuel filter Ignitor Fan blades Motor Flush every 150-200 hours of operation or as needed Replace every 500 hours of operation or once a year Wash and dry with soap and water every 500 hours of operation or as needed Clean twice a heating season or as needed No maintenance required Clean every season or as needed Not required/permanently lubricated See Storing, Transporting, or Shipping, page 7 See Air Output, Air Intake, and Lint Filters, page 10 See Air Output, Air Intake, and Lint Filters, page 10 See Fuel Filter, page 11 See Fan, page 10 TROUBLESHOOTING WARNING: Never service heater while it is plugged in, operating or hot. Severe burns and electrical shock can occur. FAULT CONDITION POSSIBLE CAUSE REMEDY Motor does not start five seconds 1. No power to heater 1. Check circuit breaker in elecafter heater is plugged intrical panel 2. ON/OFF switch not in the 2. Verify the ON/OFF switch is in ON(|) position ON (|) position and light is on 3. Thermostat setting is too low 3. Turn thermostat knob to a higher setting WARNING: High voltage! 4. Bad electrical connection between motor and ignition control assembly or ignition control assembly and power cord 5. Binding pump rotor 6. Defective ignition control assembly 7. Defective mo...

Otros modelos de este manual:
Eléctrico - BC115DT (2.43 mb)
Eléctrico - BC165DT (2.43 mb)
Eléctrico - BC55CT (2.43 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría