Iniciar sesión:
Votos - 3, Puntuación media: 3.7 ( )

Manual de usuario DeLonghi, modelo TRF1 15

Fabricar: DeLonghi
Tamaño del archivo: 663.32 kb
Nombre del archivo: 0fd231d4-bbab-47e2-b180-443052cc15d4.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Make sure that the radiator has not been damaged during transit and that the mains cable is in working order. Do not operate the radiator if damaged. Fitting the feet Remove the feet and the wheels from the polystyrene packing. Turn the radiator upside-down on a rug or a soft surface in order to prevent damaging the paint finish. Fit the wheels to the spindles and push firmly until they click into position, then insert the foot in it seat and push it till it hooks into position (see fig.1). Electrical connection -Before plugging the radiator into the mains, check that your supply voltage is the same as that shown on the rating plate of the radiator. - If using more than one appliance at a time, it is important to ensure that the ring main is adequate to cope with the power requirements. -It is important to ensure that the socket is adequately earthed. - This radiator complies with EEC Directive 89/336 relating to electromagnetic compatibility. How to use it Switching on Plug the radiator in; position the thermostat slider to the maximum position (6); turn the appliance on by pushing the foot switch as follows: With appliance off: Press the foot switch once: only radiator on (the left side indicator light will switch on ( ). Press the foot switch twice: only fan heater on (the right side indicator light will switch on ( ). Press the foot switch three times: the combined function radiator + fan heater will be on. Press the foot switch four times: the appliance will switch off. 3 TRF1 15 Adjusting the thermostat Leave the thermostat at its highest setting until the room has reached the required temperature.Then slowly turn the thermostat slider back until you hear a click.The temperature selected in this way will then be regulated automatically and kept constant by the thermostat. Frost protection function With the thermostat slider in the position and a power selected, the unit maintains the room at a temperature of about 5°C, pre * venting freezing with minimum energy consumption. Cleaning and maintenance Your oil filled raditor is absolutely free from maintenance, fully reliable and will give many years of trouble free service. Wipe radiator with soft damp cloth; do not use detergents or abrasives. If necessary, use a vacuum cleaner to remove any built-up dirt. Some models comes fitted with on anti-dust filter in the ventilation system. Remove periodically the filter from it seat and clean it (fig.3). Attention: if you do not periodically clean the filter it could happen that the fan stops working. If this occur, proceed as follows: 1. Turn the appliance off. 2. Remove the plug from the mains and let the appliance cool down. 3. Remove the filter and clean it well. 4. Replace the filter. Important notes -Do not use your radiator close to bath, wash-basin, shower and swimming pool. -Do not use your radiator to dry laundry. -Never place the power cable on top of the radiator while it is hot. -Only use the radiator in an upright position. -The heater must be positioned at least 50 cm from furniture or other objects. -If the power cable has been damaged, it must be replaced by the manufacturer or the technical service centre or by a qualified person so as to avoid all risks. -In order to eliminate the radiator’s “new” smell,set it to maximum power for at least 8 hours when used for the first time. During this operation, the room in which the radiator is located must be ventilated. -It is perfectly normal for the radiator to make “creacking” sounds when used for the first time. (or in the case of unfrequent use). -The radiator must not be located immediately below a fixed soc ket-outlet. -The body of this radiator is filled with a precise quantity of special 4 TRF1 15 oil, so that repairs requiring the opening of the oil body must only be made by the service agent. Any oil leakage must be reported to the service agent. -Do not use this appliance in rooms having a floor area of less than 4m2 as this can lead to overheating. -If the appliance is scrapped, provisions on the disposal of oil must be respected. -The use of an extension lead is not recommended, as overheating of the extension lead may occur during the operation of the radiator. -As with any electrical appliance, whilst the instructions aim to cover as many eventualities as possible, caution and common sense should be applied when operating your appliance, particularly in the vicinity of young children. The appliance is fitted with a safety device which will switch off it in case of accidental overheating.To reset, contact an authorised ser vice centre. ATTENTION: in order to avoid any danger caused by an acciden tal resetting of the safety system, this appliance must not be powe red through an external timer. IMPORTANT: Never under any circumstances cover the appliance during operation as this would lead to dangerous overheating. IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002/96/EC. At the end of its worki...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría