Manual de usuario Ducane (HVAC), modelo RLUF80C

Fabricar: Ducane (HVAC)
Tamaño del archivo: 201.05 kb
Nombre del archivo: drluf80c-100.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


(in.) Filter Size (in.) Volts/ Hz/Phase Max. Time Delay Breaker or Fuse (amp) Trans. (V.A.) Weight (lb.) RLUF80C57/72D12 .50GPH-80oA 70,000 58,000 83 2.0 -3.0 6 16 x 25 120/60/1 15 40 225 .65GPH-80oB 90,000 74,000 RLUF80C84/95D16 .65GPH-80oB 105,000 85,000 81 2.5 -4.0 6 16 x 25 120/60/1 15 40 225 .75GPH-80oB 119,000 97,000 RLUF80C112/125D20 .85GPH-80oB 140,000 113,000 81 3.0 -5.0 6 (2) 16 X 252 120/60/1 15 40 2751.00GPH-80oB 154,000 125,000 RLUF80C57B08 .50GPH-80oA 70,000 57,000 82 2.0 -2.51 6 16 x 25 120/60/1 15 123 230 RLUF80C84/95B10 .65GPH-80oB 105,000 85,000 81 2.0 -3.51 6 16 x 25 120/60/1 15 123 230 .75GPH-80oB 119,000 97,000 RLUF80C112/125B16 .85GPH-80oB 140,000 113,000 81 4.0 -5.01 6 (2) 16 x 252 120/60/1 20 123 2801.00GPH-80oB 154,000 125,000 1 See Table for Alternate Motors for Cooling Combinations 2 Requires return air be brought to both side above 1600 CFM 3 Heating only. Additional transformer required for cooling applications. Note: Units shipped with filter(s) for side return. Note: All models are rated at 140 psi pump pressure except the RLUF80C57/72 which is rated at 100 psi Blower Performance - Belt Drive Model Motor Size (hp) Blower Size Motor Pulley (in.) Motor Pulley Adjustment Blower Pulley (in.) Belt Size (in.) Temp. Rise (oF) CFM @ .20 ext. static pressure in. W.C. RLUF80C57B08 1/6 10 x 8 3 1/4 1 Turn 7 40 55-85 820 RLUF80C84/95B10 1/4 10 x 8 4 Closed 7 41 55-851 60-902 1,170 RLUF80C112/125B16 3/4 12 x 9 4 Closed 7 41 50-801 60-902 1,550 1 Low Fire Nozzle 2 High Fire Nozzle Blower Performance - Direct Drive Model Motor Size (hp) Blower Size Temp. Rise (oF) Blower Speed CFM @ ext. static pressure in. W.C. .20 .30 .40 .50 .60 .70 .80 .90 RLUF80C57/72D12 1/3 10 x 8 50-80 High 1,412 1,356 1,299 1,222 1,154 1,075 988 890 Med High 1,260 1,217 1,172 1,120 1,060 988 914 797 Med 1,040 1,025 991 960 910 860 790 680 Low 887 878 850 830 787 742 680 605 RLUF80C84/95D16 1/2 10 x 10 50-80 High 1,756 1,693 1,940 1,590 1,495 1,361 1,250 1,095 Med High 1,445 1,425 1,400 1,335 1,287 1,200 1,065 965 Med 1,191 1,181 1,147 1,110 1,054 985 894 827 Low 989 979 961 926 880 835 775 690 RLUF80C112/125D20 3/4 12 x 11 45-75 High 2,204 2,140 2,058 2,000 1,900 1,850 1,680 1,560 Med High 1,760 1,725 1,670 1,615 1,560 1,480 1,390 1,313 Med 1,520 1,496 1,450 1,400 1,360 1,315 1,250 1,165 Low 1,366* 1,329* 1,304* 1,250* 1,210* 1,180* 1,120* 1,040* *Not recommended for heating. Temperature rise may be outside acceptable range. Alternate Motors for Cooling Combinations - Belt Drive Model Nominal Cooling Capacity Motor Size (hp) Blower Size Motor Pulley (in.) Motor Pulley Adjustment Blower Pulley (in.) Belt Size (in.) CFM @ ext. static pressure -in. W.C. (tons) .20 .30 .40 .50 RLUF80C57B08 2.0 -2.5 1/4 10 x 8 4 Closed 7 41 1,170 1,154 1,070 975 RLUF80C84/95B10 2.0 -3.5 1/2 10 x 8 4 Closed 6 39 1,550 1,495 1,430 1,370 RLUF80C112/125B16 4.0 -5.0 3/4 12 x 9 3 1/4 Closed 5 36 1,990 1,925 1,850 1,820 Note: Field converted with different size motor for cooling applications. Accessories Description Used with Kit Number Clean Out Kit All models ABRSH380-3 Tjernlund Side Wall Vent Kit1 All models ASVNT522 Field Controls Side Wall Vent Kit2 All models ASVNT523 CabinetEvaporator Coil RLUF57/72/84/95 with 15 1/2" -17 1/2" wide coil ACOILKDCC19 CabinetEvaporator Coil RLUF84/95 with 21" wide coil ACOILKDCC22 CabinetEvaporator Coil RLUF112/125 with 21"-23" wide coil ACOILKDCC27 External Filter Rack All RLUF models. AFILTHA7-2 Side Return Air Cabinet RLUF57/84/95 ARCABHA-8 Side Return Air Cabinet RLUF112/125 ARCABHA-9 Combustion Air Kit All models ABOOT571 Clean Out Cap Kit All models ACAP570 1 This can be ordered from Tjernlund, part number SSII. 2 This can be ordered from Field Controls, part number SWG-5-CK61. Side Return Aid Cabinet External Filter Rack 27 6 Model A B ARCABHA-8 15 10 ARCABHA-9 21 16 20 /1 19 /1 2 18 3/4 Requires two(2) 16 X 20 filters 16 18 3/4 1/2 3/1 24 /1 2 3/4 B 2 51 A Evaporator Coil Cabinet Model Plenum Cabinet A B C D AAOILKDCC19 18 1/2 21 1/8 19 1/2 22 1/8 AAOILKDCC22 21 1/2 22 1/4 22 1/2 23 1/4 AAOILKDCC27 25 24 1/4 26 25 5/8 Accessories Dimensions (in.) Model A B C D E RLUF80C57/72 19 1/2 18 30 5/8 19 5/8 9 3/4RLUF80C84/95 RLUF80C112/125 22 1/2 21 33 1/8 22 1/8 11 1/4 Clearances (in.) Model Number Front* Sides Rear RLUF80C57/72 4 0 0RLUF80C84/95 RLUF80C112/125 *For service requirements normally 24". 54 19/16 All specifications and illustrationssubject to change without notice andwithout incurring obligations.. For more information, contact your local Ducane distributor. 3/4 A B Power Wiring (R side) Side Return (R&Lside) Supply Control Wiring (R side) Oil Line (L side) Flue Pipe E 4 2 3/4 2 3/4 5 3/4 C 22 34 14 23 1/2 2 1/16 D 3/4 Form No. DRLUF80C-100 (7/06) ©Allied Air Enterprises, A Lennox International company 2006 Printed in U.S.A. *DRLUF80C-100-7-06* ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría