Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario Empire Comfort Systems, modelo DV-210-7SG

Fabricar: Empire Comfort Systems
Tamaño del archivo: 700.12 kb
Nombre del archivo: c59c3ce8-8ee7-4311-9991-d21c9efcf15e.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


This is a heating appliance and any panel, door or guard removed for servicing an appliance must be replaced prior to operating the appliance. State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts. General Information ThisfurnaceisdesigncertifiedinaccordancewithAmericanNational Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian Standards Association, as a Gravity Direct Vent Wall Furnace to be installed on an outside wall according to these instructions. Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change. Important All correspondence should refer to complete Model No., Serial No. and type of gas. Notice: During initial firing of this unit, its paint will bake out and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is installed. Installation in Residential Garages Gas utilization equipment in residential garages shall be installed so that all burners and burner ignition devices are located not less than 18" (457mm) above the floor. Such equipment shall be located, or protected, so it is not subject to physical damage by a moving vehicle. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54* Natural Gas and Propane Installation Code, CSA B149.1. *Available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036. High Altitudes For altitudes/elevations above 2,000 feet (610m) , input ratings should be reduced at the rate of 4 percent for each 1,000 feet (305m) above sea level. Canadian High Altitudes for locations having an elevation above mean sea level between 2,000 feet (610m) and 4,500 feet (1370m), the manifold pressure is to be decreased from 4.0" w.c. (.996kPa) to 3.2" w.c. (.797kPa) for Natural Gas and from 10.0" w.c. (2.49kPa) to 8.0" w.c. (1.99kPa) for Propane Gas. Installation on Rugs and Tile If this appliance is to be installed directly on carpeting, tile, or other combustible material, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is primarily for rugs that may be extremely thick and light-color tile that may discolor. SPECIFICATIONS Model DV-210 DV-215 Input BTU/HR (KW/H) 10,000 (2.9) 15,000 (4.4) Height 21 3/8" (543mm) 24 7/8" (632mm) Width 16 1/4 (413mm) 20 1/4" (514mm) Depth 9 3/8" (239mm) 9 3/8" (239mm) Gas Inlet 1/2" (13mm) 1/2" (13mm) Options for Above Furnances Blower DVB-1 DVB-1 Vinyl Siding Vent Kit DV-822 DV-822 Page 6 12433-7-0107 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explo- sion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by • If you cannot reach your gas supplier, call the hand. When lighting the pilot, follow these instructions fire department. exactly. C. Use only your hand to push in or turn the gas control B. BEFORE LIGHTING smell all around the appliance knob. Never use tools. If the knob will not push in area for gas. Be sure to smell next to the floor because or turn by hand, don't try to repair it; call a qualisome gas is heavier than air and will settle on the fied service technician. Force or attempted repair floor. may result in a fire or explosion. WHAT TO DO IF YOU SMELL GAS D. Do not use this appliance if any part has been under • Do not try to light any appliance. water. Immediately call a qualified service techni• Do not touch any electrical switch; cian to inspect the appliance and to replace any part do not use any phone in your building. of the control system and any gas control which has • Immediatelycallyourgassupplierfromaneighbor's been under water. phone. Follow the gas supplier's instructions. 1. STOP! Read the safety information above. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the appliance (if appli- cable). 4. Remove control access panel (front panel). 5. Push in gas control knob slightly and turn clockwise to "OFF". NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force. 6. Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step. 7. Remove the pilot access cover located on the combustion chamber. 8. Find pilot - follow metal tube from gas control. The pilot is behind the pilot access cover. 9. Turn knob on gas control counterclockwise to "PILOT." 10. Push in control knob all the way and h...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría